An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT

被引:15
作者
Anam, Choirul [1 ]
Mahdani, Fahmi Rosydiansyah [1 ]
Dewi, Winda Kusuma [1 ]
Sutanto, Heri [1 ]
Triadyaksa, Pandji [1 ]
Haryanto, Freddy [2 ]
Dougherty, Geoff [3 ]
机构
[1] Diponegoro Univ, Fac Sci & Math, Dept Phys, Semarang 50275, Cent Java, Indonesia
[2] Bandung Inst Technol, Fac Math & Nat Sci, Dept Phys, Bandung, West Java, Indonesia
[3] Calif State Univ Channel Isl, Dept Appl Phys & Med Imaging, Camarillo, CA USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2021年 / 22卷 / 09期
关键词
CT dose index (CTDI); patient dose; size-specific dose estimates (SSDE); water-equivalent diameter (D-w); CHEST; INDEX; HEAD; DOSIMETRY; ABDOMEN; PELVIS; SCAN; SSDE;
D O I
10.1002/acm2.13367
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The aim of this study is to propose an algorithm for the automated calculation of water-equivalent diameter (D-w) and size-specific dose estimation (SSDE) from clinical computed tomography (CT) images containing one or more substantial body part. Methods All CT datasets were retrospectively acquired by the Toshiba Aquilion 128 CT scanner. The proposed algorithm consisted of a contouring stage for the D-w calculation, carried out by taking the six largest objects in the cross-sectional image of the patient's body, followed by the removal of the CT table depending on the center position (y-axis) of each object. Validation of the proposed algorithm used images of patients who had undergone chest examination with both arms raised up, one arm placed down and both arms placed down, images of the pelvic region consisting of one substantial object, and images of the lower extremities consisting of two separated areas. Results The proposed algorithm gave the same results for D-w and SSDE as the previous algorithm when images consisted of one substantial body part. However, when images consisted of more than one substantial body part, the new algorithm was able to detect all parts of the patient within the image. The D-w values from the proposed algorithm were 9.5%, 15.4%, and 39.6% greater than the previous algorithm for the chest region with one arm placed down, both arms placed down, and images with two legs, respectively. The SSDE values from the proposed algorithm were 8.2%, 11.2%, and 20.6% lower than the previous algorithm for the same images, respectively. Conclusions We have presented an improved algorithm for automated calculation of D-w and SSDE. The proposed algorithm is more general and gives accurate results for both D-w and SSDE whether the CT images contain one or more than one substantial body part.
引用
收藏
页码:313 / 323
页数:11
相关论文
共 34 条
  • [1] Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice
    Abuhaimed, Abdullah
    Martin, Colin J.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 74 : 30 - 39
  • [2] An evaluation of computed tomography dose index measurements using a pencil ionisation chamber and small detectors
    Anam, Choirul
    Fujibuchi, Toshioh
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2019, 39 (01) : 112 - 124
  • [3] A SIMPLIFIED METHOD FOR THE WATER-EQUIVALENT DIAMETER CALCULATION TO ESTIMATE PATIENT DOSE IN CT EXAMINATIONS
    Anam, Choirul
    Arif, Idam
    Haryanto, Freddy
    Widita, Rena
    Lestari, Fauzia P.
    Adi, Kusworo
    Dougherty, Geoff
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 185 (01) : 42 - 49
  • [4] A SIMPLE METHOD FOR CALIBRATING PIXEL VALUES OF THE CT LOCALIZER RADIOGRAPH FOR CALCULATING WATER-EQUIVALENT DIAMETER AND SIZE-SPECIFIC DOSE ESTIMATE
    Anam, Choirul
    Fujibuchi, Toshioh
    Toyoda, Takatoshi
    Sato, Naoki
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 179 (02) : 158 - 168
  • [5] THE SIZE-SPECIFIC DOSE ESTIMATE (SSDE) FOR TRUNCATED COMPUTED TOMOGRAPHY IMAGES
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) : 313 - 320
  • [6] The impact of patient table on size-specific dose estimate (SSDE)
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    McLean, Donald
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2017, 40 (01) : 153 - 158
  • [7] Automated Calculation of Water-equivalent Diameter (DW) Based on AAPM Task Group 220
    Anam, Choirul
    Haryanto, Freddy
    Widita, Rena
    Arif, Idam
    Dougherty, Geoff
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 320 - 333
  • [8] CT dosimetry: comparison of measurement techniques and devices
    Bauhs, John A.
    Vrieze, Thomas J.
    Primak, Andrew N.
    Bruesewitz, Michael R.
    McCollough, Cynthia H.
    [J]. RADIOGRAPHICS, 2008, 28 (01) : 245 - 253
  • [9] Boone J.M., 2011, SIZE SPECIFIC DOSE E
  • [10] The trouble with CTDI100
    Boone, John M.
    [J]. MEDICAL PHYSICS, 2007, 34 (04) : 1364 - 1371