Field-stable SQUID magnetometer with sub-fT Hz-1/2 resolution based on sub-micrometer cross-type Josephson tunnel junctions

被引:65
作者
Schmelz, M. [1 ]
Stolz, R. [1 ]
Zakosarenko, V. [1 ]
Schoenau, T. [1 ]
Anders, S. [1 ]
Fritzsch, L. [1 ]
Mueck, M. [2 ]
Meyer, H-G [1 ]
机构
[1] Inst Photon Technol, D-07702 Jena, Germany
[2] Univ Giessen, Inst Appl Phys, D-35392 Giessen, Germany
关键词
QUANTUM INTERFERENCE DEVICE; DC SQUID; NOISE;
D O I
10.1088/0953-2048/24/6/065009
中图分类号
O59 [应用物理学];
学科分类号
摘要
We report on the development of a new family of magnetic field sensors with exceptionally low magnetic field noise, as low as 0.3 fT Hz(-1/2). Beside this, they exhibit high usable voltage swings of more than 150 mu V-pp and tolerable background fields during cool-down of up to 6.5 mT. In operation mode they recover completely from magnetization pulses of up to 76 mT, which makes them well suited for applications such as low-field magnetic resonance imaging. With respect to their easy and reliable use as well as their field resolution in the sub-fT Hz(-1/2) range, the presented SQUID sensors are adequate for many applications, such as in geophysics or in biomagnetism.
引用
收藏
页数:5
相关论文
共 16 条
[1]   Sub-micrometer-sized, cross-type Nb-AlOx-Nb tunnel junctions with low parasitic capacitance [J].
Anders, S. ;
Schmelz, M. ;
Fritzsch, L. ;
Stolz, R. ;
Zakosarenko, V. ;
Schoenau, T. ;
Meyer, H-G .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2009, 22 (06)
[2]  
Cantor R., 2004, SQUID HDB, P171, DOI DOI 10.1002/3527603646.CH5
[3]   Low noise multiwasher superconducting interferometer [J].
Carelli, P ;
Castellano, MG ;
Torrioli, G ;
Leoni, R .
APPLIED PHYSICS LETTERS, 1998, 72 (01) :115-117
[4]  
Clarke J, 1996, NATO ADV SCI I E-APP, V329, P1
[5]  
DANSTKER E, 1996, APPL PHYS LETT, V69, P4099
[6]   Highly sensitive and easy-to-use SQUID sensors [J].
Drung, D. ;
Assmann, C. ;
Beyer, J. ;
Kirste, A. ;
Peters, M. ;
Ruede, F. ;
Schurig, Th. .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) :699-704
[7]   THEORY FOR THE MULTILOOP DC SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER AND EXPERIMENTAL-VERIFICATION [J].
DRUNG, D ;
KNAPPE, S ;
KOCH, H .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :4088-4098
[8]   DOUBLE DC SQUID FOR FLUX-LOCKED-LOOP OPERATION [J].
FOGLIETTI, V .
APPLIED PHYSICS LETTERS, 1991, 59 (04) :476-478
[9]  
LEROUX C, 2007, P EXPL 07 5 DEC INT
[10]   SQUID detected NMR in microtesla magnetic fields [J].
Matlachov, AN ;
Volegov, PL ;
Espy, MA ;
George, JS ;
Kraus, RH .
JOURNAL OF MAGNETIC RESONANCE, 2004, 170 (01) :1-7