Cu-water nanofluid flow and heat transfer in a heat exchanger tube equipped with cross-cut twisted tape

被引:80
作者
Nakhchi, M. E. [1 ]
Esfahani, J. A. [2 ]
机构
[1] Sharif Univ Technol, Sch Mech Engn, Tehran, Iran
[2] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad 917751111, Iran
关键词
Nanofluid; Cross-cut twisted tape; Turbulent flow; Thermal performance; CIRCULAR TUBE; PERFORMANCE ASSESSMENT; FRICTION FACTOR; TURBULENT-FLOW; PRESSURE-DROP; TRANSFER ENHANCEMENT; CYLINDER; LAMINAR; SQUARE;
D O I
10.1016/j.powtec.2018.08.087
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents a numerical analysis for Cu-water nanofluid flow through a circular duct inserted with cross-cut twisted tape with alternate axis (CCTA). Three dimensional (RNG) k - is an element of turbulence model is applied to simulate this problem. All simulations are performed for plain tube and nine different CCTA geometries in the range of width ratio (b/w) from 0.7 to 0.9, length ratio (s/w) from 2 to 2.5, Reynolds numbers in the range of 5000 to 15,000 and volume fraction of nanoparticles from 0 to 1.5%. The calculated results indicate that the swirl flow created by CCTA is transferred from the tube core to the near wall regions. This results in higher fluid mixing, which enhances heat transfer and friction factor near the tube wall. The results show that the heat transfer coefficient increases up to 23.20% with increasing the nanoparticle volume fraction from 0% to 1.5%. Finally, it is shown that the thermal performance increases by increasing the volume fraction of nanoparticles inside the duct. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:985 / 994
页数:10
相关论文
共 35 条
[1]  
[Anonymous], 1904, NATURE
[2]   Heat transfer and friction factor characteristics in turbulent flow through a tube fitted with perforated twisted tape inserts [J].
Bhuiya, M. M. K. ;
Chowdhury, M. S. U. ;
Saha, M. ;
Islam, M. T. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2013, 46 :49-57
[3]   THE VISCOSITY OF CONCENTRATED SUSPENSIONS AND SOLUTIONS [J].
BRINKMAN, HC .
JOURNAL OF CHEMICAL PHYSICS, 1952, 20 (04) :571-571
[4]   Thermal performances of tubular flows enhanced by ribbed spiky twist tapes with and without edge notches [J].
Chang, Shyy Woei ;
Huang, Bo Jyun .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 73 :645-663
[5]   Thermohydraulics of Turbulent Flow Through Heat Exchanger Tubes Fitted with Circular-rings and Twisted Tapes [J].
Eiamsa-ard, Smith ;
Kongkaitpaiboon, Vichan ;
Nanan, Kwanchai .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2013, 21 (06) :585-593
[6]   Thermal characteristics in round tube fitted with serrated twisted tape [J].
Eiamsa-ard, Smith ;
Promvonge, Pongjet .
APPLIED THERMAL ENGINEERING, 2010, 30 (13) :1673-1682
[7]   Performance assessment in a heat exchanger tube with alternate clockwise and counter-clockwise twisted-tape inserts [J].
Eiamsa-ard, Smith ;
Promvonge, Pongjet .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (7-8) :1364-1372
[8]  
Ellahi, 2018, RECENT DEV NANOFLUID
[9]   Structural impact of kerosene-Al2O3 nanoliquid on MHD Poiseuille flow Chock for with variable thermal conductivity: Application of cooling process [J].
Ellahi, R. ;
Zeeshan, A. ;
Shehzad, N. ;
Alamri, Sultan Z. .
JOURNAL OF MOLECULAR LIQUIDS, 2018, 264 :607-615
[10]   On boundary layer nano-ferroliquid flow under the influence of low oscillating stretchable rotating disk [J].
Ellahi, R. ;
Tariq, M. H. ;
Hassan, M. ;
Vafai, K. .
JOURNAL OF MOLECULAR LIQUIDS, 2017, 229 :339-345