Japanese research and development on metallic biomedical, dental, and healthcare materials

被引:43
作者
Niinomi, M
Hanawa, T
Narushima, T
机构
[1] Toyohashi Univ Technol, Dept Prod Syst Engn, Toyohashi, Aichi 4418580, Japan
[2] Tokyo Med & Dent Univ, Tokyo, Japan
[3] Tohoku Univ, Sendai, Miyagi 980, Japan
关键词
D O I
10.1007/s11837-005-0076-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
There is considerable demand for metallic materials for use in medical and dental devices. Metals and alloys are widely used as biomedical materials and are indispensable in the medical field. In dentistry, metal is used for restorations, orthodontic wires, and dental implants. This article describes R&D on metallic biomaterials primarily conducted by the members of the Japan Institute of Metals.
引用
收藏
页码:18 / 24
页数:7
相关论文
共 90 条
[1]   Fatigue, fretting fatigue and corrosion characteristics of biocompatible beta type titanium alloy conducted with various thereto-mechanical treatments [J].
Akahori, T ;
Niinomi, M ;
Fukui, H ;
Suzuki, A .
MATERIALS TRANSACTIONS, 2004, 45 (05) :1540-1548
[2]   Effects of thermomechanical processings on fatigue properties of Ti-29Nb-13Ta-4.6Zr for biomedical applications [J].
Akahori, T ;
Niinomi, M ;
Ishimizu, K ;
Fukui, H ;
Suzuki, A .
JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2003, 67 (11) :652-660
[3]   Fatigue properties and microstructure of newly developed Ti-29Nb-14Ta-4.6Zr for biomedical applications [J].
Akahori, T ;
Niinomi, M ;
Maekawa, T ;
Fukui, H ;
Suzuki, A .
JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2002, 66 (07) :715-722
[4]   Mechanical properties of forged low Ni and C-containing Co-Cr-Mo biomedical implant alloy [J].
Chiba, A ;
Kumagai, K ;
Takeda, H ;
Nomura, N .
PRICM 5: THE FIFTH PACIFIC RIM INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS AND PROCESSING, PTS 1-5, 2005, 475-479 :2317-2321
[5]   THE INFLUENCE OF MICROSTRUCTURE ON THE ADHESIVE WEAR-RESISTANCE OF A CO-CR-MO ALLOY [J].
CLEMOW, AJT ;
DANIELL, BL .
WEAR, 1980, 61 (02) :219-231
[6]   THE UNLUBRICATED SLIDING WEAR BEHAVIOR OF A WROUGHT COBALT-CHROMIUM ALLOY AGAINST MONOLITHIC CERAMIC COUNTERFACES [J].
COOPER, CV ;
ROLLEND, CL ;
KROUSE, DH .
JOURNAL OF TRIBOLOGY-TRANSACTIONS OF THE ASME, 1989, 111 (04) :668-674
[7]  
HANAWA T, 1991, BONE-BIOMATERIAL INTERFACE, P49
[8]   Effects of biological factors on the repassivation current of titanium [J].
Hanawa, T ;
Kohayama, Y ;
Hiromoto, S ;
Yamamoto, A .
MATERIALS TRANSACTIONS, 2004, 45 (05) :1635-1639
[9]   XPS characterization of the surface oxide film 316L stainless steel samples that were located in quasi-biological environments [J].
Hanawa, T ;
Hiromoto, S ;
Yamamoto, A ;
Kuroda, D ;
Asami, K .
MATERIALS TRANSACTIONS, 2002, 43 (12) :3088-3092
[10]   Surface oxide films on titanium alloys regenerated in Hanks' solution [J].
Hanawa, T ;
Hiromoto, S ;
Asami, K ;
Okuno, O ;
Asaoka, K .
MATERIALS TRANSACTIONS, 2002, 43 (12) :3000-3004