Optimization of vapor anode multi-tube alkali metal thermoelectric converter based on an integrated model

被引:7
作者
Zhu, Lei [1 ,2 ]
Jiang, Xinbiao [2 ]
Li, Huaqi [1 ,2 ]
Kang, Xiaoya [1 ,2 ]
Tian, Xiaoyan [2 ]
Chen, Sen [2 ]
Qiu, Suizheng [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, Xian, Shanxi, Peoples R China
[2] Northwest Inst Nucl Technol, Xian, Shanxi, Peoples R China
关键词
AMTEC; Thermoelectric converter; Integrated model; Vapor anode; Optimization; POWER-SYSTEM; AMTEC CELLS; PERFORMANCE; DESIGN; PLUTO/EXPRESS; EVAPORATOR; ELECTRODES; REACTOR; WICK; SIDE;
D O I
10.1016/j.apenergy.2019.114117
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The alkali metal thermal to electric converter (AMTEC) is a promising technology for direct conversion of heat to electricity. Design optimization and cell fabrication have been attracting wide interest to improve the cell performance. An integrated analysis model has been developed in this paper. The model includes three coupled parts of a thermal model, an electric model, and a pressure loss model, which are solved by numerical iteration method. All radiation view factors in the cell are calculated by the thermal radiation analysis software RadCAD based on Monte-Carlo ray-tracing technique to accurately and stably simulate the heat flux between the radiation surfaces to support design optimization. The integrated analysis model's predictions are in good agreement with experimental results of PX-3A cell for a wide range of external loads, which confirms the accuracy of the integrated analysis model and the rationality of the solution processes. After model validation, the effects of various parameters on the cell performance are investigated, including the cold end temperature, geometry of the heat shield, number of BASE tubes, heat loss through the cell wall, and electrode material. The optimization suggestion and optimal parameter range are given in the analyses. At last, an integrative optimization is performed using achievable parameters under current technology. The peak power and conversion efficiency have been improved from 4 W to 6.7 W and 13.5% to 18.1%, respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Ryan MA, 2001, AIP CONF PROC, V552, P1088, DOI 10.1063/1.1358055
  • [32] Ryan MA, 2000, AIP CONF PROC, V504, P1377
  • [33] Ryan MA, 1992, P 27 INT EN CONV ENG
  • [34] Design, analyses, and fabrication procedure of AMTEC cell, test assembly, and radioisotope power system for outer-planet missions
    Schock, A
    Noravian, H
    Or, C
    Kumar, V
    [J]. ACTA ASTRONAUTICA, 2002, 50 (08) : 471 - 510
  • [35] Coupled thermal, electrical, and fluid flow analyses of AMTEC multitude cell with adiabatic side wall
    Schock, A
    Or, C
    Noravian, H
    [J]. SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM, PTS 1-3: 1ST CONFERENCE ON FUTURE SCIENCE & EARTH SCIENCE MISSIONS; 1ST CONFERENCE ON SYNERGISTIC POWER & PROPULSION SYSTEMS TECHNOLOGY; 1ST CONFERENCE ON APPLICATIONS OF THERMOPHYSICS IN MICROGRAVITY; 2ND CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; - 2ND CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 14TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION, 1997, (387): : 1381 - 1394
  • [36] Steinbruck M., 1993, 28 INTERSOCIETY ENER, V1 1, P799
  • [37] Tournier J, 1999, EXPT INVESTIGATION 1
  • [38] Tournier JM, 1998, AIP CONF PROC, P1552
  • [39] Tournier JM, 1998, AIP CONF PROC, P1595
  • [40] Capillary limit of evaporator wick in alkali metal thermal-to-electric converters
    Tournier, JM
    El-Genk, MS
    [J]. JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2002, 16 (01) : 141 - 153