Calculation of Coincidence Summing Correction Factors for an HPGe detector using GEANT4

被引:13
作者
Giubrone, G. [1 ]
Ortiz, J. [1 ]
Gallardo, S. [2 ]
Martorell, S.
Bas, M. C. [3 ]
机构
[1] Univ Politecn Valencia, Lab Radiactividad Ambiental, E-46022 Valencia, Spain
[2] Univ Politecn Valencia, Inst Univ Seguridad Ind Radiofis & Medioambiental, Camino de Vera S-N, E-46022 Valencia, Spain
[3] Univ Politecn Valencia, Dept Estadist & Invest Operat Aplicadas & Calidad, E-46022 Valencia, Spain
关键词
Coincidence Summing; HPGe detector; Monte Carlo; GEANT4; GAMMA-RAY SPECTROMETRY; SIMULATION; CODE;
D O I
10.1016/j.jenvrad.2016.04.008
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this paper was to calculate the True Coincidence Summing Correction Factors (TSCFs) for an HPGe coaxial detector in order to correct the summing effect as a result of the presence of Y-88 and Co-60 in a multigamma source used to obtain a calibration efficiency curve. Results were obtained for three volumetric sources using the Monte Carlo toolkit, GEANT4. The first part of this paper deals with modeling the detector in order to obtain a simulated full energy peak efficiency curve. A quantitative comparison between the measured and simulated values was made across the entire energy range under study. The True Summing Correction Factors were calculated for Y-88 and Co-60 using the full peak efficiencies obtained with GEANT4. This methodology was subsequently applied to Cs-134, and presented a complex decay scheme. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:114 / 118
页数:5
相关论文
共 50 条
[31]   Characterization of HPGe gamma spectrometers by geant4 Monte Carlo simulations [J].
László Szentmiklósi ;
Tamás Belgya ;
Boglárka Maróti ;
Zoltán Kis .
Journal of Radioanalytical and Nuclear Chemistry, 2014, 300 :553-558
[32]   LHAASO-KM2A detector simulation using Geant4 [J].
Cao, Zhen ;
Aharonian, F. ;
An, Q. ;
Axikegu ;
Bai, Y. X. ;
Bao, Y. W. ;
Bastieri, D. ;
Bi, X. J. ;
Bi, Y. J. ;
Cai, J. T. ;
Cao, Q. ;
Cao, W. Y. ;
Cao, Zhe ;
Chang, J. ;
Chang, J. F. ;
Chen, A. M. ;
Chen, E. S. ;
Chen, Liang ;
Chen, Lin ;
Chen, Long ;
Chen, M. J. ;
Chen, M. L. ;
Chen, Q. H. ;
Chen, S. H. ;
Chen, S. Z. ;
Chen, T. L. ;
Chen, Y. ;
Cheng, N. ;
Cheng, Y. D. ;
Cui, M. Y. ;
Cui, S. W. ;
Cui, X. H. ;
Cui, Y. D. ;
Dai, B. Z. ;
Dai, H. L. ;
Dai, Z. G. ;
Dong, X. Q. ;
Duan, K. K. ;
Fan, J. H. ;
Fan, Y. Z. ;
Fang, J. ;
Fang, K. ;
Feng, C. F. ;
Feng, L. ;
Feng, S. H. ;
Feng, X. T. ;
Feng, Y. L. ;
Gabici, S. ;
Gao, B. ;
Gao, C. D. .
RADIATION DETECTION TECHNOLOGY AND METHODS, 2024, 8 (03) :1437-1447
[33]   Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry [J].
Lee, Jieun ;
Kim, HyoJin ;
Kye, Yong Uk ;
Lee, Dong Yeon ;
Kim, Jeung Kee ;
Jo, Wol Soon ;
Kang, Yeong-Rok .
NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (05) :1754-1759
[34]   Application of GEANT4 simulation on calibration of HPGe detectors for cylindrical environmental samples [J].
Nikolic, J. D. ;
Jokovic, D. ;
Todorovic, D. ;
Rajacic, M. .
JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (02) :N47-N55
[35]   Optimization study of a new β +- γ coincidence positron annihilation lifetime spectrometer using Geant4 [J].
Xu, W. ;
Li, Y. H. ;
Pan, Z. W. ;
Liu, J. D. ;
Zhang, H. J. ;
Ye, B. J. .
JOURNAL OF INSTRUMENTATION, 2024, 19 (06)
[36]   Coincidence-summing correction equations in gamma-ray spectrometry with p-type HPGe detectors [J].
Tomarchio, E. ;
Rizzo, S. .
RADIATION PHYSICS AND CHEMISTRY, 2011, 80 (03) :318-323
[37]   True coincidence summing correction and mathematical efficiency modeling of a well detector [J].
Jaederstroem, H. ;
Mueller, W. F. ;
Atrashkevich, V. ;
Adekola, A. S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 :264-268
[38]   Comparison of CdZnTe neutron detector models using MCNP6 and Geant4 [J].
Wilson, Emma ;
Anderson, Mike ;
Prendergasty, David ;
Cheneler, David .
ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2017), 2018, 170
[39]   Calculation of electron Dose Point Kernel in water with GEANT4 for medical application [J].
Guimaraes, C. C. ;
Moralles, M. ;
Sene, F. F. ;
Martinelli, J. R. ;
Okuno, E. .
NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 :93-96
[40]   Virtual point detector: Application to coincidence-summing correction in gamma-ray spectrometry [J].
Rizzo, S. ;
Tomarchio, E. .
APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) :1448-1450