Mechanical Performance Study of Beam-Column Connection with U-Shaped Steel Damper

被引:2
作者
Qu, Chun-Xu [1 ]
Xu, Yu-Wen [2 ]
Gao, Jin-He [2 ]
Zhou, Wei-Hao [2 ]
Zheng, Bao-Zhu [2 ]
Li, Peng [2 ]
机构
[1] Dalian Univ Technol, Sch Civil Engn, Dalian 116023, Peoples R China
[2] East China Univ Technol, Sch Civil & Architectural Engn, Nanchang 344000, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
U-shaped steel damper; quasi-static testing; mechanical property; semi-rigid connection; energy dissipation;
D O I
10.3390/ma15207085
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The article proposes the use of a semi-rigid energy-dissipation connection combined with a U-shaped metal damper to avoid brittle failure of rigid steel beam-column connections under seismic loading. The U-shaped metal damper connects the H-section column and the H-section beam to form a new energy-dissipation connection as an energy-dissipation member. Compared with the existing research, this connection has a stable energy-dissipation performance and great ductility. To clarify the mechanism of energy dissipation, mechanical models under two U-shaped damping deformation modes are established. The calculation formulas for the yield load and stiffness are derived for the corresponding deformation mode using the unit load method. Taking the T-shaped beam-column connection and the application of U-shaped steel damper in the beam-column connection as an example, the mechanical model of the connection is established and the calculation formulas for the yield load and stiffness are derived. At the same time, the connection is subjected to a quasi-static test under cyclic loading. The results show that the hysteretic curve of the test is complete and that the skeleton curve is accurate compared to the theory. The error range of the initial stiffness and yield load obtained by the test and the theoretical formula is kept within 20%, indicating that the theoretical formula is reasonable and feasible. In addition, the correctness of the finite element model is verified by establishing a finite element model and comparing it with the test. The mechanical responses of purely rigid connections and rigid semi-rigid composite connections are compared and analyzed using a multi-story and multi-span plane frame as an example. The results show that the model with semi-rigid connections, compared to the model with rigid connections, avoids the gradual loss of bearing capacity caused by the failure of the connection area of the second floor of the main structure and improves the seismic performance of the main structure.
引用
收藏
页数:18
相关论文
共 33 条
[1]  
Chen A., 2007, J BUILD STRUCT, VS1, P77
[2]   Seismic Performance and Strengthening of Purlin Roof Structures Using a Novel Damping-Limit Device [J].
Chen, Baokui ;
Jia, Bao ;
Wen, Ming ;
Li, Xiaodong .
FRONTIERS IN MATERIALS, 2021, 8
[3]   Influence of site factors on offshore ground motions: Observed Results and Numerical Simulation [J].
Chen, Baokui ;
Wang, Dongsheng ;
Chen, Shaolin ;
Hu, Sicong .
SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2021, 145
[4]   Parametric study and design of rib-reinforced steel moment connections [J].
Chen, CC ;
Lu, CA ;
Lin, CC .
ENGINEERING STRUCTURES, 2005, 27 (05) :699-708
[5]  
Chen Jing Chen Jing, 2007, Journal of SAT Agricultural Research, V3, P1
[6]   Analysis of the Mechanical Properties and Parameter Sensitivity of a U-Shaped Steel Damper [J].
Gao, Jinhe ;
Xi, Jiahuan ;
Xu, Yuwen ;
Ding, Jiajun ;
Zhu, Junwen ;
Chang, Yi ;
Chen, Baokui .
FRONTIERS IN MATERIALS, 2021, 8
[7]  
Gutscher D., 2008, RAILW TRACK STRUCT, V104, P21
[8]   Mechanical property of U-Shaped 65Mn steel bumpers for seismic base isolation [J].
Han Miao ;
Wang Yuandong ;
Du Hongkai ;
Cui Xiangdong .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2021, 20 (03) :791-802
[9]   Improving seismic performance of framed structures with steel curved dampers [J].
Hsu, H. -L. ;
Halim, H. .
ENGINEERING STRUCTURES, 2017, 130 :99-111
[10]  
[黄东升 HUANG Dongsheng], 2011, [建筑结构学报, Journal of Building Structures], V32, P87