摘要
Here we present a new and rapid immunofiltration assay for simultaneous detection of HIV p24 and hepatitis B virus antigens. The assay platform is composed of a 13 mm nitrocellulose filter spotted with capturing bioprobes and inserted in a Swinnex((R)) syringe filter holder. Samples and reagents are flown through the nitrocellulose filter by manual pressure on the syringe. A colorimetric detection allows for naked eye results interpretation. The assay provides sensitivity in the picomolar range in just 5 min, even using low volumes of sample in complex matrix. Probe deposition by spotting allows for flexible combinations of different capturing agents and multiple diagnoses; furthermore, the very simple and inexpensive set-up makes the syringe-based immunoassay on paper microarray a suitable diagnostic system for resource-limited settings. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:315 / 320
页数:6
相关论文
共 16 条
  • [1] Overcoming mass transport limitations to achieve femtomolar detection limits on silicon protein microarrays
    Cretich, Marina
    Bagnati, Marta
    Damin, Francesco
    Sola, Laura
    Chiari, Marcella
    [J]. ANALYTICAL BIOCHEMISTRY, 2011, 418 (01) : 164 - 166
  • [2] A NEW VISUAL ENZYME-IMMUNOASSAY OF METHAMPHETAMINE USING LINEAR WATER-SOLUBLE POLYELECTROLYTES
    DZANTIEV, BB
    CHOI, MJ
    PARK, J
    CHOI, J
    ROMANENKO, OG
    ZHERDEV, AV
    EREMIN, SA
    IZUMRUDOV, VA
    [J]. IMMUNOLOGY LETTERS, 1994, 41 (2-3) : 205 - 211
  • [3] Immunochromatographic strip test for rapid detection of diphtheria toxin: Description and multicenter evaluation in areas of low and high prevalence of diphtheria
    Engler, KH
    Efstratiou, A
    Norn, D
    Kozlov, RS
    Selga, I
    Glushkevich, TG
    Tam, M
    Melnikov, VG
    Mazurova, IK
    Kim, VE
    Tseneva, GY
    Titov, LP
    George, RC
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2002, 40 (01) : 80 - 83
  • [4] Microfluidic designs and techniques using lab-on-a-chip devices for pathogen detection for point-of-care diagnostics
    Foudeh, Amir M.
    Didar, Tohid Fatanat
    Veres, Teodor
    Tabrizian, Maryam
    [J]. LAB ON A CHIP, 2012, 12 (18) : 3249 - 3266
  • [5] Antiretroviral treatment of adult HIV infection - 2008 recommendations of the International AIDS Society USA panel
    Hammer, Scott M.
    Eron, Joseph J., Jr.
    Reiss, Peter
    Schooley, Robert T.
    Thompson, Melanie A.
    Walmsley, Sharon
    Cahn, Pedro
    Fischl, Margaret A.
    Gatell, Jose M.
    Hirsch, Martin S.
    Jacobsen, Donna M.
    Montaner, Julio S. G.
    Richman, Douglas D.
    Yeni, Patrick G.
    Volberding, Paul A.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2008, 300 (05): : 555 - 570
  • [6] Kaplan Jonathan E., 2009, Morbidity and Mortality Weekly Report, V58, P1
  • [7] Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards
    Lafleur, Lisa
    Stevens, Dean
    McKenzie, Katherine
    Ramachandran, Sujatha
    Spicar-Mihalic, Paolo
    Singhal, Mitra
    Arjyal, Amit
    Osborn, Jennifer
    Kauffman, Peter
    Yager, Paul
    Lutz, Barry
    [J]. LAB ON A CHIP, 2012, 12 (06) : 1119 - 1127
  • [8] Rapid Multiplexed Immunoassay for Simultaneous Serodiagnosis of HIV-1 and Coinfections
    Lochhead, Michael J.
    Todorof, Kathryn
    Delaney, Marie
    Ives, Jeffrey T.
    Greef, Charles
    Moll, Kevin
    Rowley, Keagan
    Vogel, Kurt
    Myatt, Chris
    Zhang, Xing-Quan
    Logan, Cathy
    Benson, Constance
    Reed, Sharon
    Schooley, Robert T.
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (10) : 3584 - 3590
  • [9] Microfluidic immunosensor design for the quantification of interleukin-6 in human serum samples
    Messina, German A.
    Panini, Nancy V.
    Martinez, Noelia A.
    Raba, Julio
    [J]. ANALYTICAL BIOCHEMISTRY, 2008, 380 (02) : 262 - 267
  • [10] Vertical flow immunoassay (VFA) biosensor for a rapid one-step immunoassay
    Oh, Young Kyoung
    Joung, Hyou-Arm
    Kim, Sanghyo
    Kim, Min-Gon
    [J]. LAB ON A CHIP, 2013, 13 (05) : 768 - 772