A compact multi-parameter detection system based on hydrodynamic sequential injection for sensitive determination of phosphate, nitrite, and nitrate in water samples

被引:0
|
作者
Khongpet, Wanpen [1 ]
Yanu, Pattama [1 ]
Pencharee, Somkid [2 ]
Puangpila, Chanida [1 ,5 ]
Hartwell, Supaporn Kradtap [3 ]
Lapanantnoppakhun, Somchai [1 ,5 ]
Yodthongdee, Yutdanai [1 ]
Paukpol, Autchara [1 ]
Jakmunee, Jaroon [1 ,4 ,5 ]
机构
[1] Chiang Mai Univ, Fac Sci, Dept Chem, Lab Analyt Instrumentat & Electrochem Innovat, Chiang Mai 50200, Thailand
[2] Ubon Ratchathani Univ, Fac Sci, Dept Phys, Ubon Ratchathani 34190, Thailand
[3] Xavier Univ, Dept Chem, 3800 Victory Pkwy, Cincinnati, OH 45207 USA
[4] Chiang Mai Univ, Fac Sci, Environm Sci Res Ctr, Ctr Excellence Innovat Chem, Chiang Mai 50200, Thailand
[5] Chiang Mai Univ, Res Ctr Chem Dev Hlth Promoting Prod Northern Res, Fac Sci, Chiang Mai 50200, Thailand
关键词
ENVIRONMENTAL-SAMPLES; LIQUID-CHROMATOGRAPHY; REACTIVE PHOSPHATE; DEVICE; ORTHOPHOSPHATE; ANALYZER; SENSOR;
D O I
10.1039/c9ay02327e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A miniaturized microfluidic hydrodynamic sequential injection system for multi-parameter analysis with a sensitive colorimetric detection was developed to improve the analytical performance for the measurement of phosphate, nitrite, and nitrate based on molybdenum blue and Griess methods. A homemade colorimetric detection with a light emitting diode as a light source and phototransistor light sensor was integrated into the microfluidic platform to achieve a low cost compact system with low reagent consumption and high sensitivity. Under the optimized working conditions, a linear calibration graph of phosphate (two working range), nitrite and nitrate (as nitrogen, N) in the range of 0.01-0.1 and 0.3-1.0 mg of PO43- P L-1, 0.005-0.05 mg of NO2- N L-1 and 0.01-0.12 mg of NO3- N L-1, respectively were achieved with a sample-throughput of 10 h(-1). The limit of detections were 0.005 mg of PO43- P L-1, 0.0026 mg of NO2- N L-1 and 0.005 mg of NO3- N L-1. The percentage of recovery for phosphate, nitrite, and nitrate were 90.3-115.0, 90.0-117.0 and 91.3-117.0, respectively, with relative standard deviations in the range of 1.07-4.90%. Capabilities of the developed device for consecutive analysis of multiple analytes were demonstrated to be an excellent choice for water quality monitoring.
引用
收藏
页码:855 / 864
页数:10
相关论文
共 50 条
  • [21] Study of Multi-parameter in TDLAS Detection System Based on LabVIEW
    Ye, Weilin
    Liu, Weihao
    Xia, Zikun
    Xiao, Xupeng
    Xu, Xiaohuan
    Wu, Tao
    Wu, Fupei
    2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 1170 - 1175
  • [22] Determination of nitrate and nitrite in dairy samples by sequential injection using an in-line cadmium-reducing column
    Lima, M. J. Reis
    Fernandes, Silvia M. V.
    Rangel, Antonio O. S. S.
    INTERNATIONAL DAIRY JOURNAL, 2006, 16 (12) : 1442 - 1447
  • [23] Sequential determination of multi-nutrient elements in natural water samples with a reverse flow injection system
    Lin, Kunning
    Ma, Jian
    Yuan, Dongxing
    Feng, Sichao
    Su, Haitao
    Huang, Yongming
    Shangguan, Qipei
    TALANTA, 2017, 167 : 166 - 171
  • [24] Simultaneous Determination of Nitrate, Nitrite and Phosphate in Environmental Samples by High Performance Liquid Chromatography with UV Detection
    Moshoeshoe, Mohau N.
    Obuseng, Veronica
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2018, 71 : 79 - 85
  • [25] A Compact Microcontrolled Microfluidic System for Photometric Determination of Phosphate in Natural Water Samples
    Pessoa-Neto, Osmundo Dantas
    Silva, Tiago Almeida
    dos Santos, Vagner Bezerra
    Fatibello-Filho, Orlando
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2015, 68 (07) : 1108 - 1114
  • [26] Sequential Injection Analysis-Based System for On-Line Monitoring of Nitrite and Nitrate in Wastewaters
    Rui A. S. Lapa
    José L. F. C. Lima
    Ivone V. O. S. Pinto
    Analytical Sciences, 2000, 16 : 1157 - 1160
  • [27] Sequential injection analysis-based system for on-line monitoring of nitrite and nitrate in wastewaters
    Lapa, RAS
    Lima, JLFC
    Pinto, IVOS
    ANALYTICAL SCIENCES, 2000, 16 (11) : 1157 - 1160
  • [28] A Sequential Injection System for the Spectrophotometric Determination of Calcium, Magnesium and Alkalinity in Water Samples
    Raquel B. R. Mesquita
    António O. S. S. Rangel
    Analytical Sciences, 2004, 20 : 1205 - 1210
  • [29] A sequential injection system for the spectrophotometric determination of calcium, magnesium and alkalinity in water samples
    Mesquita, RBR
    Rangel, AOSS
    ANALYTICAL SCIENCES, 2004, 20 (08) : 1205 - 1210
  • [30] A MEMS-Based Multi-Parameter Integrated Chip and Its Portable System for Water Quality Detection
    Wu, Ziyue
    Wang, Jiaqi
    Bian, Chao
    Tong, Jianhua
    Xia, Shanhong
    MICROMACHINES, 2020, 11 (01)