Transoesophageal echocardiography accurately detects cardiac output variation:: a prospective comparison with thermodilution in cardiac surgery

被引:29
作者
Parra, V. [1 ,2 ]
Fita, G. [3 ]
Rovira, I. [3 ]
Matute, P. [3 ]
Gomar, C. [3 ]
Pare, C. [4 ]
机构
[1] Univ Chile, Fac Med, Inst Ciencias Biomed, Santiago 9, Chile
[2] Univ Chile, Hosp Clin, Santiago, Chile
[3] Univ Barcelona, Hosp Clin, E-08007 Barcelona, Spain
[4] Univ Barcelona, Unidad Ecocardiog, E-08007 Barcelona, Spain
关键词
cardiac output; thermodilution; catheterization swan ganz; echocardiography Doppler; cardiac surgical procedures;
D O I
10.1017/S0265021507001354
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objective: Intraoperative Doppler ultrasound can be used to measure cardiac output by trans-oesophageal echocardiography. Recently, its reliability, when compared to the thermodilution technique, has been questioned. The purpose of this study was to compare intraoperative changes in cardiac output measured by echo-Doppler and by thermodilution in cardiac surgery. We also assessed the agreement between the techniques. Methods: Fifty cardiac surgical patients (38 male, 12 female, mean age of 63.4 +/- 14.3 yr) were prospectively included after approval by the Ethics Committee of the Institution. Cardiac output was assessed by thermodilution, with 10 mL saline at 12 degrees C, and simultaneously and blindly by echo-Doppler in deep transgastric view with pulsed wave Doppler at the level of the left ventricular outflow tract. Matched thermodilution cardiac output and echo-Doppler cardiac output measurements were taken three times at the end of expiration, both pre- and post-cardiopulmonary bypass. Results: Echo-Doppler measurements were obtained in 44 patients (88916). In three patients, Doppler recordings could not be obtained adequately, and three developed left ventricular outflow tract obstruction after bypass. Bland-Altman analysis revealed a bias of 0.015 L min(-1), with narrow limits of agreement (-1.21 to 1.22 L min(-1)) and 29.1% error. Echo-Doppler was accurate (92% sensitivity and 71% specificity, P = 0.008 by receiver operating characteristic curves) for detecting more than 10% of change in thermodilution cardiac output. There were no complications related to the study. Conclusions: The agreement between cardiac output by echo-Doppler and by thermodilution is clinically acceptable and transoesophageal echocardiography is a reliable tool to assess significant cardiac output changes in a population of selected patients.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 30 条
  • [1] Am Soc Anesthesiologists Task Forc, 2003, ANESTHESIOLOGY, V99, P988
  • [2] Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution
    Bettex, DA
    Hinselmann, V
    Hellermann, JP
    Jenni, R
    Schmid, ER
    [J]. ANAESTHESIA, 2004, 59 (12) : 1184 - 1192
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: Summary article - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE committee to update the 1997 guidelines for the clinical application of echocardiography)
    Cheitlin, MD
    Armstrong, WF
    Aurigemma, GP
    Beller, GA
    Bierman, FZ
    Davis, JL
    Douglas, PS
    Faxon, DP
    Gillam, LD
    Kimball, TR
    Kussmaul, WG
    Pearlman, AS
    Philbrick, JT
    Rakowski, H
    Thys, DM
    Antman, EM
    Smith, SC
    Alpert, JS
    Gregoratos, G
    Anderson, JL
    Hiratzka, LF
    Faxon, DP
    Hunt, SA
    Fuster, V
    Jacobs, AK
    Gibbons, RJ
    Russell, RO
    [J]. CIRCULATION, 2003, 108 (09) : 1146 - 1162
  • [5] A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    Critchley, LAH
    Critchley, JAJH
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1999, 15 (02) : 85 - 91
  • [6] DARMON PL, 1994, ANESTHESIOLOGY, V80, P796, DOI 10.1097/00000542-199404000-00011
  • [7] FEIGHENBAUN H, 2005, FEIGENBAUMS ECHOCARD, P159
  • [8] MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHIC DOPPLER IMAGING ACCURATELY DETERMINES CARDIAC-OUTPUT MEASUREMENTS IN CRITICALLY ILL PATIENTS
    FEINBERG, MS
    HOPKINS, WE
    DAVILAROMAN, VG
    BARZILAI, B
    [J]. CHEST, 1995, 107 (03) : 769 - 773
  • [9] FIEGHENBAUN H, 2005, FEIGENBAUMS ECHOCARD, P214
  • [10] Kallmeyer IJ, 2001, ANESTH ANALG, V92, P1126