Trimmed autocalibrating k-space estimation based on structured matrix completion

被引:5
作者
Bydder, Mark [1 ]
Rapacchi, Stanislas [1 ]
Girard, Olivier [1 ]
Guye, Maxime [1 ,2 ]
Ranjeva, Jean-Philippe [1 ]
机构
[1] Aix Marseille Univ, Ctr Resonance Magnet Biol & Med, UMR CNRS 7339, Marseille, France
[2] CHU Timone, AP HM, CEMREM, Pole Imagerie Med, Marseille, France
关键词
Artefacts; Parallel imaging; Structured low rank approximation; IRIS; Robust; MOTION ARTIFACTS; RECONSTRUCTION; ALGORITHM; NOISE;
D O I
10.1016/j.mri.2017.07.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Parallel imaging allows the reconstruction of undersampled data from multiple coils. This provides a means to reject and regenerate corrupt data (e.g. from motion artefact). The purpose of this work is to approach this problem using the SAKE parallel imaging method. Theory and methods: Parallel imaging methods typically require calibration by fully sampling the center of k-space. This is a challenge in the presence of corrupted data, since the calibration data may be corrupted which leads to an errors-in-variables problem that cannot be solved by least squares or even iteratively reweighted least squares. The SAKE method, based on matrix completion and structured low rank approximation, was modified to detect and trim these errors from the data. Results: Simulated and actual corrupted datasets were reconstructed with SAKE, the proposed approach and a more standard reconstruction method (based on solving a linear equation) with a data rejection criterion. The proposed approach was found to reduce artefacts considerably in comparison to the other two methods. Conclusion: SAKE with data trimming improves on previous methods for reconstructing images from grossly corrupted data. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:88 / 94
页数:7
相关论文
共 24 条
[1]   Thermal noise variance of a receive radiofrequency coil as a respiratory motion sensor [J].
Andreychenko, A. ;
Raaijmakers, A. J. E. ;
Sbrizzi, A. ;
Crijns, S. P. M. ;
Lagendijk, J. J. W. ;
Luijten, P. R. ;
van den Berg, C. A. T. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) :221-228
[2]  
[Anonymous], 2009, Wiley Series in Probability and Statistics, DOI DOI 10.1002/9780470434697.CH7
[3]  
Ashley G, 2013, MAGN RESON MED, V69, P1094
[4]  
Atkinson D, 1999, MAGNET RESON MED, V41, P163, DOI 10.1002/(SICI)1522-2594(199901)41:1<163::AID-MRM23>3.0.CO
[5]  
2-9
[6]   Weiszfeld's Method: Old and New Results [J].
Beck, Amir ;
Sabach, Shoham .
JOURNAL OF OPTIMIZATION THEORY AND APPLICATIONS, 2015, 164 (01) :1-40
[7]   Partial fourier partially parallel imaging [J].
Bydder, M ;
Robson, MD .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) :1393-1401
[8]   Detection and elimination of motion artifacts by regeneration of k-space [J].
Bydder, M ;
Larkman, DJ ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (04) :677-686
[9]   Using the Robust Principal Component Analysis Algorithm to Remove RF Spike Artifacts from MR Images [J].
Campbell-Washburn, Adrienne E. ;
Atkinson, David ;
Nagy, Zoltan ;
Chan, Rachel W. ;
Josephs, Oliver ;
Lythgoe, Mark F. ;
Ordidge, Roger J. ;
Thomas, David L. .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) :2517-2525
[10]  
Derbyshire A. J., 2011, J CARDIOVASC MAGN R, V13, P23