A Biomechanical Comparison of the Pullout Strength of No. 2 FiberWire Suture and 2-mm FiberWire Tape in Bovine Rotator Cuff Tendons

被引:53
作者
Bisson, Leslie J. [1 ]
Manohar, Leslie M. [1 ]
机构
[1] Univ Sports Med, Amherst, NY 14226 USA
关键词
DOUBLE-ROW REPAIR; SUPRASPINATUS TENDON; IN-VITRO; CONFIGURATIONS; EQUIVALENT; FIXATION; FAILURE; STITCH; MODEL;
D O I
10.1016/j.arthro.2010.04.075
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To biomechanically compare No. 2 polyblend suture with 2-mm polyblend tape in a bovine rotator cuff model as well as in isolation. Methods: Ten paired bovine infraspinatus specimens were randomly assigned to simple suture fixation with either No. 2 polyblend suture or 2-mm polyblend tape. Each specimen was subjected to cyclic testing followed by load-to-failure testing. Elongation, ultimate tensile load, and stiffness were determined. The failure method was recorded. Isolated suture specimens were also cycled and tested with the same protocol. Results: For tendon-suture specimens, testing showed no significant difference for elongation (1.44 +/- 0.41 mm v 1.90 +/- 1.15 mm, P = .192) or stiffness (67 +/- 13 N/mm v 66 +/- 11 N/mm, P = .757). Statistical significance was found for ultimate tensile load (168 +/- 73 N v 184 +/- 83 N, P = .046). The most common mode of failure for both groups of specimens was disruption of the tendon by the suture. Isolated suture specimens showed significant differences for ultimate tensile load (349 +/- 7 N v 937 +/- 93 N, P = .001) and stiffness (85 +/- 12 N/mm v 218 +/- 20 N/mm, P = .002) but not for elongation (0.26 +/- 0.05 mm v 0.19 +/- 0.04 mm, P = .124). Conclusions: Using the described testing method in bovine rotator cuff specimens, we found no difference in ultimate tensile load, stiffness, or elongation between the 2 tested sutures. Testing of the sutures in isolation showed that the 2-mm tape was approximately 3 times as stiff as the No. 2 suture and failed at 3 times the loads of the No. 2 suture. Clinical Relevance: The larger 2-mm tape does not diminish the biomechanical performance of rotator cuff-suture specimens in comparison to No. 2 suture. Although the effect of tape on the vascularity of the rotator cuff is not known, the larger tape does not negatively affect elongation, ultimate tensile load, or stiffness in this in vitro animal model.
引用
收藏
页码:1463 / 1468
页数:6
相关论文
共 16 条
[1]   Surgical repair of the rotator cuff: a biomechanical evaluation of different tendon grasping and bone suture fixation techniques [J].
Baleani, M ;
Schrader, S ;
Veronesi, CA ;
Rotini, R ;
Giardino, R ;
Toni, A .
CLINICAL BIOMECHANICS, 2003, 18 (08) :721-729
[2]   Influence of suture material on the biomechanical behavior of suture-tendon specimens - A controlled study in bovine rotator cuff [J].
Bisson, Leslie J. ;
Manohar, Leslie M. ;
Wilkins, Ryan D. ;
Gurske-Deperio, Jennifer ;
Ehrensberger, Mark T. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (05) :907-912
[3]  
Chokshi BV, 2006, BULL HOSP JT DIS, V63, P123
[4]   Triple-loaded single-anchor stitch configurations: An analysis of cyclically loaded suture-tendon interface security [J].
Coons, David A. ;
Barber, F. Alan ;
Herbert, Morley A. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (11) :1154-1158
[5]   Mode of failure for rotator cuff repair with suture anchors identified at revision surgery [J].
Cummins, CA ;
Murrell, GAC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (02) :128-133
[6]   Supraspinatus tendon organizational and mechanical properties in a chronic rotator cuff tear animal model [J].
Gimbel, JA ;
Van Kleunen, JP ;
Mehta, S ;
Perry, SM ;
Williams, GR ;
Soslowsky, LJ .
JOURNAL OF BIOMECHANICS, 2004, 37 (05) :739-749
[7]   TENSILE PROPERTIES OF THE SUPRASPINATUS TENDON [J].
ITOI, E ;
BERGLUND, LJ ;
GRABOWSKI, JJ ;
SCHULTZ, FM ;
GROWNEY, ES ;
MORREY, BF ;
AN, KN .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (04) :578-584
[8]   Biomechanical comparison of traditional and locked suture configurations for arthroscopic repairs of the rotator cuff [J].
Koganti, Anil K. ;
Adamson, Gregory J. ;
Gregersen, Colin S. ;
Pink, Marilyn M. ;
Shankwiler, James A. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (11) :1832-1838
[9]  
Ma CB, 2004, J BONE JOINT SURG AM, V86A, P1211
[10]   Biomechanical evaluation of arthroscopic rotator cuff repairs: Double-row compared with single-row fixation [J].
Ma, CB ;
Comerford, L ;
Wilson, J ;
Puttlitz, CM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (02) :403-410