Dependence of radiochromic film optical density post-exposure kinetics on dose and dose fractionation

被引:31
作者
Ali, I
Costescu, C
Vicic, M
Dempsey, JF
Williamson, JF
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Washington Univ, Med Ctr, Radiat Oncol Ctr, St Louis, MO 63110 USA
[3] Univ Florida, Dept Radiat Oncol, Gainesville, FL 32610 USA
关键词
D O I
10.1118/1.1587611
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiochromic film (RCF) has been shown to be a precise and accurate secondary planar dosimeter for acute exposure radiation fields. However, its application to low dose-rate brachytherapy has been questioned because of possible dose-rate effects. To address this concern, we have measured the optical density (OD) of Model 55-2 RCF as a function of time (interval between the completion of irradiation and densitometry using a 633 nm laser scanner) following exposure (from less than I hour to 90 days) for single and split doses from 1 Gy to 100 Gy. Our work demonstrates that film darkening as a function of post-irradiation time depends significantly on total dose, with films exposed to lower doses developing faster than films given higher doses. At 1 Gy, the OD 90 days after exposure is 200% larger than that measured 1 h after exposure compared to a 20% increase over 90 days for doses larger than 20 Gy. An empirical model with time-independent, fast and slow growth terms was used to fit single exposure. data. The dependence of the resulting best-fit parameters on dose was investigated. Splitting the dose into two fractions (20 Gy followed by doses of 1-80 Gy 24 h later) results in modest post-irradiation time-dependent changes in the total optical density (at most 15% at small doses), which dissipates within 20 hours following the second exposure. This experimental finding is consistent with the predictions of a simple cumulative dose superposition model. Overall, both experimental and empirical modeling suggest that dose-rate effects may be relatively small despite the strong dependence of film darkening kinetics on total dose. However, more experimental evaluation of radiochromic film response dependence on dose rate and dose-time-fractionation patterns is needed. (C) 2003 American Association of Physicists in Medicine.
引用
收藏
页码:1958 / 1967
页数:10
相关论文
共 21 条
[1]   Quantitative optical densitometry with scanning-laser film digitizers [J].
Dempsey, JF ;
Low, DA ;
Kirov, AS ;
Williamson, JF .
MEDICAL PHYSICS, 1999, 26 (08) :1721-1731
[2]   Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions [J].
Dempsey, JF ;
Low, DA ;
Mutic, S ;
Markman, J ;
Kirov, AS ;
Nussbaum, GH ;
Williamson, JF .
MEDICAL PHYSICS, 2000, 27 (10) :2462-2475
[3]   Use of a new type of radiochromic film, a new parallel-plate micro-chamber, MOSFETs, and TLD 800 microcubes in the dosimetry of small beams [J].
Francescon, P ;
Cora, S ;
Cavedon, C ;
Scalchi, P ;
Reccanello, S ;
Colombo, F .
MEDICAL PHYSICS, 1998, 25 (04) :503-511
[4]   TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12) :2015-2036
[5]   Measurement and calculation of heterogeneity correction factors for an Ir-192 high dose-rate brachytherapy source behind tungsten alloy and steel shields [J].
Kirov, AS ;
Williamson, JF ;
Meigooni, AS ;
Zhu, Y .
MEDICAL PHYSICS, 1996, 23 (06) :911-919
[6]   GafChromic MD-55: Investigated as a precision dosimeter [J].
Klassen, NV ;
van der Zwan, L ;
Cygler, J .
MEDICAL PHYSICS, 1997, 24 (12) :1924-1934
[7]  
LATHI BP, 1998, SIGNAL PROCESSING LI, P204
[8]   Phantoms for IMRT dose distribution measurement and treatment verification [J].
Low, DA ;
Gerber, RL ;
Mutic, S ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05) :1231-1235
[9]   Quantitative dosimetric verification of an IMRT planning and delivery system [J].
Low, DA ;
Mutic, S ;
Dempsey, JF ;
Gerber, RL ;
Bosch, WR ;
Perez, CA ;
Purdy, JA .
RADIOTHERAPY AND ONCOLOGY, 1998, 49 (03) :305-316
[10]   Novel radiochromic films for clinical dosimetry [J].
McLaughlin, WL ;
Puhl, JM ;
AlSheikhly, M ;
Christou, CA ;
Miller, A ;
Kovacs, A ;
Wojnarovits, L ;
Lewis, DF .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :263-268