Evaluation of Alternate Isotope-Coded Derivatization Assay (AIDA) in the LC-MS/MS analysis of aldehydes in exhaled breath condensate

被引:31
作者
Manini, Paola [1 ,2 ]
Andreoli, Roberta [1 ,2 ]
Sforza, Stefano [3 ]
Dall'Asta, Chiara [3 ]
Galaverna, Gianni [3 ]
Mutti, Antonio [1 ]
Niessen, Wilfried M. A. [4 ]
机构
[1] Univ Parma, Lab Ind Toxicol, Dept Clin Med Nephrol & Hlth Sci, I-43126 Parma, Italy
[2] Univ Parma, Natl Inst Occupat Safety & Prevent ISPESL, Res Ctr, I-43100 Parma, Italy
[3] Univ Parma, Dept Organ & Ind Chem, I-43124 Parma, Italy
[4] Hyphen MassSpec Consultancy, NL-2332 XT Leiden, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 27期
关键词
Malondialdehyde; 4-Hydroxynonenal; Exhaled breath condensate; Alternate Isotope-Coded Derivatization Assay (AIDA); LC-MS; Matrix effect; CHROMATOGRAPHY-MASS SPECTROMETRY; AIR SAMPLES; QUANTIFICATION; BIOMARKERS; WORKERS; MATRIX;
D O I
10.1016/j.jchromb.2010.02.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present the application of a novel isotope dilution method, named Alternate Isotope-Coded Derivatization Assay (AIDA), to the quantitative analysis of hydrazone derivatives of malondialdehyde (MDA) and 4-hydroxynonenal (4-HNE) in exhaled breath condensate (EBC) samples using liquid chromatography-tandem mass spectrometry. AIDA is based on the alternate derivatization of the analyte(s) with reagents that are available in two pure isotopic forms, respectively "light" and "heavy", by using light-derivatized standards for the quantification of the heavy-derivatized analytes, and vice versa. To this purpose, 2,4-dinitro-3,5,6-trideuterophenylhydrazine (d(3)-DNPH) has been synthesized and used as "heavy" reagent in combination with commercial "light" DNPH. Using the AIDA method, any unknown concentration of the analyte in the matrix can be calculated without the need of a calibration curve. An external calibration method has been also investigated for comparative purpose. The stability of DNPH and d3-DNPH derivatives was verified by excluding any exchange of hydrazones with each other. In the range of concentrations of biological interest, e.g., 2-40 nM for MDA and 0.5-10 nM for 4-HNE, the derivatization reactions of MDA and 4-HNE with DNPH and d3-DNPH showed overlapping kinetics and comparable yields. The MS response of both DNPH and d3-DNPH hydrazones was similar. The precision of AIDA, calculated as %RSD, was within 3.2-8% for MDA and 4.5-11% for 4-HNE. Accuracy was tested by analyzing a spiked EBC pool sample and acceptable results (accuracy within 98-108% for MDA and 93-114% for 4-HNE) were obtained by AIDA after subtraction of the blank, which was not negligible. The results of quantitative analysis of MDA and 4-HNE in EBC samples obtained by AIDA assay with four analyses per sample were in good agreement with those obtained by external calibration method on the same samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2616 / 2622
页数:7
相关论文
共 15 条
[1]   Determination of patterns of biologically relevant aldehydes in exhaled breath condensate of healthy subjects by liquid chromatography/atmospheric chemical ionization tandem mass spectrometry [J].
Andreoli, R ;
Manini, P ;
Corradi, M ;
Mutti, A ;
Niessen, WMA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (07) :637-645
[2]   The effect of inhaled chromium on different exhaled breath condensate biomarkers among chrome-plating workers [J].
Caglieri, A ;
Goldoni, M ;
Acampa, O ;
Andreoli, R ;
Vettori, MV ;
Corradi, M ;
Apostoli, P ;
Mutti, A .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2006, 114 (04) :542-546
[3]  
Corradi M, 2008, MED LAV, V99, P49
[4]   Comparison between exhaled and sputum oxidative stress biomarkers in chronic airway inflammation [J].
Corradi, M ;
Pignatti, P ;
Manini, P ;
Andreoli, R ;
Goldoni, M ;
Poppa, M ;
Moscato, G ;
Balbi, B ;
Mutti, A .
EUROPEAN RESPIRATORY JOURNAL, 2004, 24 (06) :1011-1017
[5]   Aldehydes in exhaled breath condensate of patients with chronic obstructive pulmonary disease [J].
Corradi, M ;
Rubinstein, I ;
Andreoli, R ;
Manini, P ;
Caglieri, A ;
Poli, D ;
Alinovi, R ;
Mutti, A .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 167 (10) :1380-1386
[6]   Aldehydes and glutathione in exhaled breath condensate of children with asthma exacerbation [J].
Corradi, M ;
Folesani, G ;
Andreoli, R ;
Manini, P ;
Bodini, A ;
Piacentini, G ;
Carraro, S ;
Zanconato, S ;
Baraldi, E .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2003, 167 (03) :395-399
[7]   Exhaled breath condensate as a suitable matrix to assess lung dose and effects in workers exposed to cobalt and tungsten [J].
Goldoni, M ;
Catalani, S ;
De Palma, G ;
Manini, P ;
Acampa, O ;
Corradi, M ;
Bergonzi, R ;
Apostoli, P ;
Mutti, A .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2004, 112 (13) :1293-1298
[8]   Liquid chromatography-mass spectrometry in occupational toxicology: A novel approach to the study of biotransformation of industrial chemicals [J].
Manini, P ;
Andreoli, R ;
Niessen, WMA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) :21-37
[9]   Matrix effects in quantitative pesticide analysis using liquid chromatography-mass spectrometry [J].
Niessen, W. M. A. ;
Manini, P. ;
Andreoli, R. .
MASS SPECTROMETRY REVIEWS, 2006, 25 (06) :881-899
[10]   Alternate isotope-coded derivatization assay: An isotope dilution method applied to the quantification of zearalenone in maize flour [J].
Sforza, S ;
Dall'Asta, C ;
Moseritti, A ;
Galaverna, G ;
Dossena, A ;
Marchelli, R .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (32) :5126-5130