Feasibility study of multi-purpose quality assurance phantom for pretreatment verification of volumetric modulated arc therapy

被引:6
作者
Won, H. S. [1 ,2 ]
Chung, J. B. [1 ]
Eom, K. Y. [1 ]
Hwang, D. G. [2 ]
Kang, S. W. [3 ,4 ]
Suh, T. S. [3 ,4 ]
机构
[1] Seoul Natl Univ, Dept Radiat Oncol, Bungdang Hosp, Seongnam, South Korea
[2] Sangji Univ, Dept Biomed Engn, Wonju, South Korea
[3] Catholic Univ Korea, Coll Med, Dept Biomed Engn, Seoul, South Korea
[4] Catholic Univ Korea, Coll Med, Res Inst Biomed Engn, Seoul, South Korea
来源
INTERNATIONAL JOURNAL OF RADIATION RESEARCH | 2018年 / 16卷 / 03期
关键词
Volumetric modulated arc therapy; phantom; absolute dosimetry; relative dosimetry; POINT DOSE MEASUREMENT; PINPOINT ION-CHAMBER; HIGH-ENERGY PHOTON; RADIATION-THERAPY; WATER PHANTOM; EBT2; FILM; IMRT; DOSIMETRY; RADIOTHERAPY; BEAMS;
D O I
10.18869/acadpub.ijrr.16.2.279
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The purpose of this study was to evaluate the feasibility of a multi-purpose quality assurance (QA) phantom for pretreatment verification of volumetric modulated arc therapy (VMAT). Materials and Methods: The QA phantom was constructed with polymethyl methacrylate (PMMA) to perform relative dosimetry using EBT3 film and MapCHECK, as well as absolute dosimetry using an ionization chamber. The QA phantom was constructed to perform relative dosimetry using EBT3 film and MapCHECK, as well as the absolute dosimetry using ionization chamber. In order to verify the pretreatment plans, 25 patients treated with VMAT were selected. The pretreatment plans were calculated in the Eclipse treatment planning system using the Acuros XB dose calculation algorithm and CT images for the QA phantom, with the same beam setup and monitor units (MUs) as those for patient treatment. All plans were delivered to the Varian TrueBeam accelerator equipped with a high-definition multi-leaf collimator. Results: The multi-purpose QA phantom is developed for convenient VMAT dose verification. By using the QA phantom, all 25 cases passed +/- 3% acceptability criteria in absolute dosimetry with an ionization chamber for pretreatment verification. The relative dosimetry using EBT3 film and MapCHECK system also showed high agreement of more than 90% for 2%/2-mm and 3%/3-mm criteria. Conclusion The results of this study demonstrated the good multi-purpose capabilities of the phantom for the absolute and relative dosimetry. Therefore, the developed multi-purpose QA phantom was applied in our institution for routine VMRT dose verification.
引用
收藏
页码:279 / 287
页数:9
相关论文
共 38 条
[31]   Variations in dose distribution and optical properties of Gafchromic™ EBT2 film according to scanning mode [J].
Park, Soah ;
Kang, Sei-Kwon ;
Cheong, Kwang-Ho ;
Hwang, Taejin ;
Kim, Haeyoung ;
Han, Taejin ;
Lee, Me-Yeon ;
Kim, KyoungJu ;
Bae, Hoonsik ;
Kim, Hyeong Su ;
Kim, Jung Han ;
Oh, Seung Jae ;
Suh, Jin-Suck .
MEDICAL PHYSICS, 2012, 39 (05) :2524-2535
[32]   Simplifying EPID dosimetry for IMRT treatment verification [J].
Pecharroman-Gallego, R. ;
Mans, Anton ;
Sonke, Jan-Jakob ;
Stroom, Joep C. ;
Olaciregui-Ruiz, Igor ;
van Herk, Marcel ;
Mijnheer, Ben J. .
MEDICAL PHYSICS, 2011, 38 (02) :983-992
[33]  
Price R, 2002, MED PHYS, V29, P1267
[34]  
Senthilkumar S, 2014, INT J RADIAT RES, V12, P169
[35]   A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy [J].
Son, Jaeman ;
Baek, Taesung ;
Lee, Boram ;
Shin, Dongho ;
Park, Sung Yong ;
Park, Jeonghoon ;
Lim, Young Kyung ;
Lee, Se Byeong ;
Kim, Jooyoung ;
Yoon, Myonggeun .
RADIOLOGY AND ONCOLOGY, 2015, 49 (03) :307-313
[36]  
Swamy ST, 2016, INT J RADIAT RES, V14, P81
[37]  
Wiezorek T, 2005, STRAHLENTHER ONKOL, V181, P468, DOI 10.1007/s00066-005-1381-z
[38]   Monte-Carlo-based perturbation and beam quality correction factors for thimble ionization chambers in high-energy photon beams [J].
Wulff, J. ;
Heverhagen, J. T. ;
Zink, K. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (11) :2823-2836