Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy Strategies for Locally Advanced Non-Small-Cell Lung Cancer

被引:14
|
作者
Selek, Ugur [1 ,2 ]
Bolukbasi, Yasemin [2 ]
Welsh, James W. [2 ]
Topkan, Erkan [3 ]
机构
[1] Koc Univ, Dept Radiat Oncol, Fac Med, Istanbul, Turkey
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX USA
[3] Baskent Univ, Fac Med, Dept Radiat Oncol, Adana, Turkey
关键词
3-D conformal radiotherapy; intensity modulated radiotherapy; lung cancer; ELECTIVE NODAL IRRADIATION; THERAPY-ONCOLOGY-GROUP; PHASE-III TRIAL; RADIATION-THERAPY; CONCURRENT CHEMOTHERAPY; DOSE-ESCALATION; TARGET VOLUME; TUMOR MOTION; SEQUENTIAL CHEMORADIOTHERAPY; THORACIC RADIOTHERAPY;
D O I
10.5152/balkanmedj.2014.14529
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chemoradiotherapy is the current standard of care in patients with advanced inoperable stage IIIA or IIIB non-small cell lung cancer (NSCLC). Three-dimensional radiotherapy (3DCRT) has been a trusted method for a long time and has well-known drawbacks, most of which could be improved by Intensity Modulated Radiotherapy (IMRT). IMRT is not currently the standard treatment of locally advanced NSCLC, but almost all patients could benefit to a degree in organ at risk sparing, dose coverage conformality, or dose escalation. The most critical step for a radiation oncology department is to strictly evaluate its own technical and physical capabilities to determine the ability of IMRT to deliver an optimal treatment plan. This includes calculating the internal tumor motion (ideally 4DCT or equivalent techniques), treatment planning software with an up-to-date heterogeneity correction algorithm, and daily image guidance. It is crucial to optimise and individualise the therapeutic ratio for each patient during the decision of 3DCRT versus IMRT. The current literature rationalises the increasing use of IMRT, including 4D imaging plus PET/CT, and encourages the applicable knowledge-based and individualised dose escalation using advanced daily image-guided radiotherapy.
引用
收藏
页码:286 / 294
页数:9
相关论文
共 50 条
  • [1] Comparison of Toxicity Between Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy for Locally Advanced Non-small-cell Lung Cancer
    Ling, Diane C.
    Hess, Clayton B.
    Chen, Allen M.
    Daly, Megan E.
    CLINICAL LUNG CANCER, 2016, 17 (01) : 18 - 23
  • [2] Intensity-Modulated Radiotherapy, Not 3 Dimensional Conformal, Is the Preferred Technique for Treating Locally Advanced Lung Cancer
    Chang, Joe Y.
    SEMINARS IN RADIATION ONCOLOGY, 2015, 25 (02) : 110 - 116
  • [3] Comparison of inverse-planned three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for non-small-cell lung cancer
    Christian, Judith A.
    Bedford, James L.
    Webb, Steve
    Brada, Michael
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 735 - 741
  • [4] INTENSITY-MODULATED RADIOTHERAPY FOR LOCALLY ADVANCED NON-SMALL-CELL LUNG CANCER: A DOSE-ESCALATION PLANNING STUDY
    Lievens, Yolande
    Nulens, An
    Gaber, Mousa Amr
    Defraene, Gilles
    De Wever, Walter
    Stroobants, Sigrid
    Van den Heuvel, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 306 - 313
  • [5] Hypofractionated Intensity-Modulated Radiotherapy for Patients With Non-Small-Cell Lung Cancer
    Pollom, Erqi L.
    Qian, Yushen
    Durkee, Ben Y.
    von Eyben, Rie
    Maxim, Peter G.
    Shultz, David B.
    Gensheimer, Michael
    Diehn, Maximilian
    Loo, Billy W., Jr.
    CLINICAL LUNG CANCER, 2016, 17 (06) : 588 - 594
  • [6] Comparison of efficacy and safety between simultaneous integrated boost intensity-modulated radiotherapy and conventional intensity-modulated radiotherapy in locally advanced non-small-cell lung cancer: a retrospective study
    Wang, Daquan
    Bi, Nan
    Zhang, Tao
    Zhou, Zongmei
    Xiao, Zefen
    Liang, Jun
    Chen, Dongfu
    Hui, Zhouguang
    Lv, Jima
    Wang, Xiaozhen
    Wang, Xin
    Deng, Lei
    Wang, Wenqing
    Wang, Jingbo
    Wang, Chunyu
    Lu, Xiaotong
    Xu, Kunpeng
    Wu, Linfang
    Xue, Wenji
    Feng, Qinfu
    Wang, Luhua
    RADIATION ONCOLOGY, 2019, 14 (1)
  • [7] Comparison of efficacy and safety between simultaneous integrated boost intensity-modulated radiotherapy and conventional intensity-modulated radiotherapy in locally advanced non-small-cell lung cancer: a retrospective study
    Daquan Wang
    Nan Bi
    Tao Zhang
    Zongmei Zhou
    Zefen Xiao
    Jun Liang
    Dongfu Chen
    Zhouguang Hui
    Jima Lv
    Xiaozhen Wang
    Xin Wang
    Lei Deng
    Wenqing Wang
    Jingbo Wang
    Chunyu Wang
    Xiaotong Lu
    Kunpeng Xu
    Linfang Wu
    Wenji Xue
    Qinfu Feng
    Luhua Wang
    Radiation Oncology, 14
  • [8] Acute toxicity with intensity modulated radiotherapy versus 3-dimensional conformal radiotherapy during preoperative chemoradiation for locally advanced rectal cancer
    Ng, Shu Y.
    Colborn, Kathryn L.
    Cambridge, Lajhem
    Hajj, Carla
    Yang, T. Jonathan
    Wu, Abraham J.
    Goodman, Karyn A.
    RADIOTHERAPY AND ONCOLOGY, 2016, 121 (02) : 252 - 257
  • [9] Comparison of Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy as Adjuvant Therapy for Gastric Cancer
    Minn, A. Yuriko
    Hsu, Annie
    La, Trang
    Kunz, Pamela
    Fisher, George A.
    Ford, James M.
    Norton, Jeffrey A.
    Visser, Brendan
    Goodman, Karyn A.
    Koong, Albert C.
    Chang, Daniel T.
    CANCER, 2010, 116 (16) : 3943 - 3952
  • [10] Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer
    Lopez Guerra, Jose L.
    Gomez, Daniel R.
    Zhuang, Yan
    Levy, Lawrence B.
    Eapen, George
    Liu, Hongmei
    Mohan, Radhe
    Komaki, Ritsuko
    Cox, James D.
    Liao, Zhongxing
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (04): : E537 - E543