Determining finger segmental centers of rotation in flexion-extension based on surface marker measurement

被引:84
作者
Zhang, XD [1 ]
Lee, SW [1 ]
Braido, P [1 ]
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Biomech & Ergon Lab, Urbana, IL 61801 USA
关键词
finger motion; center of rotation; surface marker; in vivo; optimization;
D O I
10.1016/S0021-9290(03)00112-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes the development of a novel algorithm for deriving finger segmental center of rotation (COR) locations during flexion-extension from measured surface marker motions in vivo. The algorithm employs an optimization routine minimizing the time-variance of the internal link lengths, and incorporates an empirically quantifiable relationship between the local movement of a surface marker around a joint (termed "surface marker excursion") and the joint flexion-extension. The latter relationship constrains and simplifies the optimization routine to make it computationally tractable. To empirically investigate this relationship and test the proposed algorithm, an experiment was conducted, in which hand cylinder-grasping movements were performed by 24 subjects (12 mates and 12 females). Spherical retro-reflective markers were placed at various surface landmarks on the dorsal aspect of each subject's right (grasping) hand, and were measured during the movements by an opto-electronic system. Analysis of experimental data revealed a highly linear relationship between the "surface marker excursion" and the marker-defined flexion-extension angle: the average R-2 in linear regression ranged from 0.89 to 0.97. The algorithm successfully determined the CORs of the distal interphalangeal, proximal interphalangeal, and metacarpophalangeal joints of digits 2-5 during measured motions. The derived CORs appeared plausible as examined in terms of the physical locations relative to surface marker trajectories and the congruency across different joints and individuals. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1097 / 1102
页数:6
相关论文
共 20 条
[1]   FORCES IN THE NORMAL AND ABNORMAL HAND [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1985, 3 (02) :202-211
[2]   NORMATIVE MODEL OF HUMAN HAND FOR BIOMECHANICAL ANALYSIS [J].
AN, KN ;
CHAO, EY ;
COONEY, WP ;
LINSCHEID, RL .
JOURNAL OF BIOMECHANICS, 1979, 12 (10) :775-788
[3]   A three-dimensional kinematic model of the human long finger and the muscles that actuate it [J].
Biggs, J ;
Horch, K .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (09) :625-639
[4]  
Brand P., 1999, CLIN BIOMECHANICS HA
[5]   A KINEMATIC MODEL OF THE HUMAN HAND TO EVALUATE ITS PREHENSILE CAPABILITIES [J].
BUCHHOLZ, B ;
ARMSTRONG, TJ .
JOURNAL OF BIOMECHANICS, 1992, 25 (02) :149-162
[6]   The use of the motion analysis system for evaluation of loss of movement in the finger [J].
Chiu, HY ;
Lin, SC ;
Su, FC ;
Wang, ST ;
Hsu, HY .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (02) :195-199
[7]   The motion analysis system and goniometry of the finger joints [J].
Chiu, HY ;
Su, FC ;
Wang, ST ;
Hsu, HY .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (06) :788-791
[8]   OPTIMAL MARKER PLACEMENT FOR CALCULATING THE INSTANTANEOUS CENTER OF ROTATION [J].
CRISCO, JJ ;
CHEN, XB ;
PANJABI, MM ;
WOLFE, SW .
JOURNAL OF BIOMECHANICS, 1994, 27 (09) :1183-1187
[9]   New least squares solutions for estimating the average centre of rotation and the axis of rotation [J].
Gamage, SSHU ;
Lasenby, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :87-93
[10]   A new method for estimating the axis of rotation and the center of rotation [J].
Halvorsen, K ;
Lesser, M ;
Lundberg, A .
JOURNAL OF BIOMECHANICS, 1999, 32 (11) :1221-1227