Monitoring of antifouling agents in water samples by on-line solid-phase extraction-liquid chromatography-atmospheric pressure chemical ionization mass spectrometry

被引:25
作者
Gimeno, RA [1 ]
Aguilar, C [1 ]
Marcé, RM [1 ]
Borrull, F [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
关键词
water analysis; pesticides; diuron; irgarol; 1051; folpet; dichlofluanid;
D O I
10.1016/S0021-9673(01)00619-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automatic method for determining diuron, irgarol 1051, folpet and dichlofluanid in seawater samples have been developed. This method is based on the on-line coupling of solid-phase extraction (SPE) with a highly crosslinked polymeric sorbent, LiChrolut EN, to liquid chromatography followed by atmospheric pressure chemical ionization (APCI) and mass spectrometry. The operational parameters affecting the APCI interface have been studied in both positive and negative ionization modes. The use of LiChrolut EN in the SPE produced recoveries of over 85% for all the compounds when 100 mi of seawater sample was preconcentrated. Calibration was carried out in both ionization modes and in full-scan and selected-ion monitoring (SIM). The method allowed all the analytes to be detected at 5 ng 1(-1) in SIM acquisition mode except folpet, which, because of its low response, could only be detected at 250 ng 1(-1). The method was used to analyse water samples taken from five different marina and fishing ports along the coast of Tarragona, Catalonia (Spain), over a 5-month period. Diuron and irgarol 1051 were detected and quantified in most samples at concentration levels ranging from 27 to 420 ng 1(-1) for diuron and from 15 to 511 ng 1(-1) for irgarol 1051. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 22 条
[1]  
Akiyama Y, 1998, J FOOD HYG SOC JPN, V39, P303, DOI 10.3358/shokueishi.39.5_303
[2]   Preparation of antisera and development of a direct enzyme-linked immunosorbent assay for the determination of the antifouling agent Irgarol 1051 [J].
Ballesteros, B ;
Barcelo, D ;
Camps, F ;
Marco, MP .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :139-147
[3]   Influence of the hapten design on the development of a competitive ELISA for the determination of the antifouling agent Irgarol 1051 at trace levels [J].
Ballesteros, B ;
Barceló, D ;
Sanchez-Baeza, F ;
Camps, F ;
Marco, MP .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4004-4014
[4]   Concentrations of the antifouling compound Irgarol 1051 and of organotins in water and sediments of German North and Baltic Sea marinas [J].
Biselli, S ;
Bester, K ;
Hühnerfuss, H ;
Fent, K .
MARINE POLLUTION BULLETIN, 2000, 40 (03) :233-243
[5]  
Castillo M, 1997, J MASS SPECTROM, V32, P1100, DOI 10.1002/(SICI)1096-9888(199711)32:10<1100::AID-JMS564>3.3.CO
[6]  
2-1
[7]   Comparison of various sample handling and analytical procedures for the monitoring of pesticides and metabolites in ground waters [J].
Fernandez-Alba, AR ;
Agüera, A ;
Contreras, M ;
Peñuela, G ;
Ferrer, I ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1998, 823 (1-2) :35-47
[8]   Simultaneous determination of antifouling herbicides in marina water samples by on-line solid-phase extraction followed by liquid chromatography-mass spectrometry [J].
Ferrer, I ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :197-206
[9]  
Hall LW, 1999, CRIT REV TOXICOL, V29, P367
[10]   Solid-phase extraction: method development, sorbents, and coupling with liquid chromatography [J].
Hennion, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :3-54