Amniotic Fluid Volume Assessment: Eight Lessons Learned

被引:5
作者
Magann, Everett F. [1 ]
Whittington, Julie R. [1 ]
Morrison, John C. [2 ]
Chauhan, Suneet P. [3 ]
机构
[1] Univ Arkansas Med Sci, Dept Obstet & Gynecol, 4301 W Markham St Slot 518, Little Rock, AR 72205 USA
[2] Univ Mississippi, Med Ctr, Dept Obstet & Gynecol, Jackson, MS 39216 USA
[3] Univ Texas Hlth Sci Ctr Houston, Dept Obstet Gynecol & Reprod Sci, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF WOMENS HEALTH | 2021年 / 13卷
关键词
amniotic fluid volume; oligohydramnios; polyhydramnios; color Doppler; subjective assessment; objective assessment; BIOPHYSICAL PROFILE; POCKET TECHNIQUE; INDEX; SINGLETON; PREGNANCIES; ACCURACY; REFLECT; TRIAL;
D O I
10.2147/IJWH.S316841
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Actual AFV can be determined by a dye-dilution technique or be directly measured at cesarean. This allows investigators to correlate estimated and actual AFVs. Lessons learned by assessing the relationship of estimated to actual AFVs. 1) Ultrasound estimates normal actual AFVs well, but abnormal AFVs poorly. 2) Quantile regression is a better statistical methodology to create a normal AFV curve across pregnancy. 3) There is no difference in the accuracy of the subjective (visualization without measurements) com-pared with the objective (visualization with measurements) technique in identifying normal and abnormal AFVs. 4) Color Doppler use leads to the over-diagnosis of oligohydramnios. 5) Intravenous hydration increases actual AFVs. 6) The estimation of AFV can be done with the transducer held perpendicular to the floor or perpendicular to the uterine contour. 7) The single deepest pocket should be used for identifying low AFVs. 8) The AFI should be used for identifying high AFVs.
引用
收藏
页码:773 / 779
页数:7
相关论文
共 23 条
  • [1] A randomised comparison between amniotic fluid index and maximum pool depth in the monitoring of post-term pregnancy
    Alfirevic, Z
    Luckas, M
    Walkinshaw, SA
    McFarlane, M
    Curran, R
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (02): : 207 - 211
  • [2] NORMAL AMNIOTIC-FLUID VOLUME CHANGES THROUGHOUT PREGNANCY
    BRACE, RA
    WOLF, EJ
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1989, 161 (02) : 382 - 388
  • [3] Ultrasonographic assessment of amniotic fluid does not reflect actual amniotic fluid volume
    Chauhan, SP
    Magann, EF
    Morrison, JC
    Whitworth, NS
    Hendrix, NW
    Devoe, LD
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (02) : 291 - 296
  • [4] Amniotic fluid index vs single deepest pocket technique during modified biophysical profile: A randomized clinical trial
    Chauhan, Suneet P.
    Doherty, Dorota D.
    Magann, Everett F.
    Cahanding, Francis
    Moreno, Frank
    Klausen, Jack H.
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (02) : 661 - 667
  • [5] DO SEMIQUANTITATIVE AMNIOTIC-FLUID INDEXES REFLECT ACTUAL VOLUME
    CROOM, CS
    BANIAS, BB
    RAMOSSANTOS, E
    DEVOE, LD
    BEZHADIAN, A
    HIETT, AK
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 167 (04) : 995 - 999
  • [6] AMNIOTIC-FLUID VOLUME ASSESSMENT - COMPARISON OF ULTRASONOGRAPHIC ESTIMATES VERSUS DIRECT MEASUREMENTS WITH A DYE-DILUTION TECHNIQUE IN HUMAN-PREGNANCY
    DILDY, GA
    LIRA, N
    MOISE, KJ
    RIDDLE, GD
    DETER, RL
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1992, 167 (04) : 986 - 994
  • [7] CORRELATION OF MEASURED AMNIOTIC-FLUID VOLUME AND SONOGRAPHIC PREDICTIONS OF OLIGOHYDRAMNIOS
    HORSAGER, R
    NATHAN, L
    LEVENO, KJ
    [J]. OBSTETRICS AND GYNECOLOGY, 1994, 83 (06) : 955 - 958
  • [8] Accuracy of the Ultrasound Estimate of the Amniotic Fluid Volume (Amniotic Fluid Index and Single Deepest Pocket) to Identify Actual Low, Normal, and High Amniotic Fluid Volumes as Determined by Quantile Regression
    Hughes, Dawn S.
    Magann, Everett F.
    Whittington, Julie R.
    Wendel, Michael P.
    Sandlin, Adam T.
    Ounpraseuth, Songthip T.
    [J]. JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (02) : 373 - 378
  • [9] Is There a Difference in Sonographic Estimation of Amniotic Fluid Volume When Measuring With the Probe Perpendicular to the Floor Compared With Perpendicular to the Uterine Contour?
    Hughes, Dawn S.
    Whittington, Julie R.
    Kim, Hyein
    Gunderman, Brianna
    Ounpraseuth, Songthip
    Magann, Everett F.
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA, 2019, 41 (09) : 1295 - 1301
  • [10] Single deepest vertical pocket or amniotic fluid index as evaluation test for predicting adverse pregnancy outcome (SAFE trial): a multicenter, open-label, randomized controlled trial
    Kehl, S.
    Schelkle, A.
    Thomas, A.
    Puhl, A.
    Meqdad, K.
    Tuschy, B.
    Berlit, S.
    Weiss, C.
    Bayer, C.
    Heimrich, J.
    Dammer, U.
    Raabe, E.
    Winkler, M.
    Faschingbauer, F.
    Beckmann, M. W.
    Suetterlin, M.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2016, 47 (06) : 674 - +