A microfluidic paper-based laser-induced fluorescence sensor based on duplex-specific nuclease amplification for selective and sensitive detection of miRNAs in cancer cells

被引:44
作者
Cai, Xiaoyu [1 ]
Zhang, Huimin [1 ]
Yu, Xiufeng [1 ]
Wang, Wei [1 ]
机构
[1] Fuzhou Univ, Sch Chem, Res Inst Photocatalysis, Minist Educ,Key Lab Analyt Sci Food Safety & Biol, Fuzhou 350116, Peoples R China
关键词
Cancer cell; Duplex-specific nuclease; Laser-induced fluorescence; microRNA; Paper-based sensor; WASTE-WATER; MICRORNAS; DEVICE; REMOVAL; ION;
D O I
10.1016/j.talanta.2020.120996
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
MicroRNAs (miRNAs) are considered as the potential biomarkers for many cancers. To determine miRNAs in cancer cells is significant for realizing these diseases. In this work, a microfluidic paper-based laser-induced fluorescence sensor based on duplex-specific nuclease (DSN) amplification was developed and applied to selectively and sensitively determine miRNAs in cancer cells. An interface for laser-induced fluorescence detection was firstly applied to perform the sample detection on the paper-based chip. Under the optimal conditions, DSN (3 mu L 0.10 U) and Taqman probes (2 mu L 2.5 x 10(-7) M) were preserved on the circles (Diameter 4 mm) of the folded paper chip. When miRNA solution was added, the mixed solution could trigger fluorescence signal amplification by cyclically digesting hybrids of miRNAs and Taqman probes by DSN. The whole determination, including sample heating process, could be accomplished within 40 min. The detection limits for miRNA-21 and miRNA-31 were 0.20 and 0.50 fM respectively, corresponding to only 1.0 and 1.5 zmol consumption of miRNAs. The testing of mismatched miRNAs showed that the method had good specificity. Finally, the method was applied to determine miRNA-21 and miRNA-31 in lysates of cancer cells of A549 and HeLa, and hepatocyte LO2. MiRNA-21 and miRNA-31 could be successfully found from the two cancer cells. The concentrations for miRNA-21 and miRNA-31 were 1.74 x 10(-13) M and 6.29 x 10(-14) M in HeLa cell lysate (3.75 x 10(4) cells/mL), 3.07 x 10(-15) M and 3.28 x 10(-15) M in A549 cell lysate (8.33 x 10(6) cells/mL) respectively. The recoveries ranged from 87.30% to 111.83%, indicating the results were reliable. The developed method was effective, selective and sensitive in the determination of miRNAs in cancer cells.
引用
收藏
页数:7
相关论文
共 34 条
[1]   Developments of microfluidic paper-based analytical devices (μPADs) for water analysis: A review [J].
Almeida, M. Ines G. S. ;
Jayawardane, B. Manori ;
Kolev, Spas D. ;
McKelvie, Ian D. .
TALANTA, 2018, 177 :176-190
[2]   Assessment of the expression level of miRNA molecules using a semi-quantitative RT-PCR approach [J].
Andoorfar, Shima ;
Tafreshi, Seyed Ali Hosseini ;
Rezvani, Zahra .
MOLECULAR BIOLOGY REPORTS, 2019, 46 (05) :5057-5062
[3]   An efficient composite material for selective lead(II) monitoring and removal from wastewater [J].
Awual, Md Rabiul .
JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2019, 7 (03)
[4]   Assessing of lead(III) capturing from contaminated wastewater using ligand doped conjugate adsorbent [J].
Awual, Md. Rabiul .
CHEMICAL ENGINEERING JOURNAL, 2016, 289 :65-73
[5]   Treatment of copper(II) containing wastewater by a newly developed ligand based facial conjugate materials [J].
Awual, Md Rabiul ;
Hasan, Md Munjur ;
Khaleque, Md Abdul ;
Sheikh, Md Chanmiya .
CHEMICAL ENGINEERING JOURNAL, 2016, 288 :368-376
[6]   Efficient selenium(IV) detection and removal from water by tailor-made novel conjugate adsorbent [J].
Awual, Md. Rabiul ;
Hasan, Md. Munjur ;
Khaleque, Md. Abdul .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 :194-202
[7]   A novel fine-tuning mesoporous adsorbent for simultaneous lead(II) detection and removal from wastewater [J].
Awual, Md. Rabiul ;
Hasan, Md. Munjur .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 :395-403
[8]   Gold-coated nanostructured carbon tape for rapid electrochemical detection of cadmium in rice with in situ electrodeposition of bismuthin paper-based analytical devices [J].
Bi, Xiao-Mei ;
Wang, He-Ru ;
Ge, Li-Qiang ;
Zhou, Dong-Mei ;
Xu, Jin-Zhong ;
Gu, Hai-Ying ;
Bao, Ning .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 :475-479
[9]   Covalent Attachment of Enzymes to Paper Fibers for Paper-Based Analytical Devices [J].
Boehm, Alexander ;
Trosien, Simon ;
Avrutina, Olga ;
Kolmar, Harald ;
Biesalski, Markus .
FRONTIERS IN CHEMISTRY, 2018, 6
[10]   Recent advances in microfluidic paper-based electrochemiluminescence analytical devices for point-of-care testing applications [J].
Chinnadayyala, Somasekhar R. ;
Park, Jinsoo ;
Hien Thi Ngoc Le ;
Santhosh, Mallesh ;
Kadam, Abhijit N. ;
Cho, Sungbo .
BIOSENSORS & BIOELECTRONICS, 2019, 126 :68-81