A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI .1. Development of a computational method

被引:65
作者
Losch, A
Eckstein, F
Haubner, M
Englmeier, KH
机构
[1] GSF-Natl. Res. Ctr. for E., Inst. for Med. Info. and Hlth. S., Neuherberg
[2] Anat. Anst. der L., München
[3] GSF-Natl. Res. Ctr. for E., Inst. for Med. Info. and Hlth. S., D-85764 Neuherberg
关键词
articular cartilage; magnetic resonance imaging; cartilage thickness; three-dimensional reconstruction; distance measurement;
D O I
10.1016/S0730-725X(97)00012-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research, In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets, A correction algorithm that compensates for the error implied in the voxel based distance measurements is implemented, Four different thickness definitions have been applied to two numerical test structures in order to judge their usability in the medical realm,The results for each of the thickness measurement methods are shown as color-coded thickness maps wrapped round the test objects, An algorithm determining at each point the minimal distance from the articular surface to the bone-cartilage interface is suggested to give the most suitable demonstration of articular cartilage, This algorithm is successfully applied to a 3-dimensional data set of human knee joint cartilage obtained with a fat-suppressed gradient-echo sequence from a healthy volunteer. A non-invasive method for determining cartilage thickness could become a very valuable tool in diagnostic radiology, orthopaedic practice and biomechanics. (C) 1997 Elsevier Science Inc.
引用
收藏
页码:795 / 804
页数:10
相关论文
共 23 条
[1]  
ALTESHIAN GA, 1991, J BIOMECH, V24
[2]   EVALUATION OF NEW ALGORITHMS FOR THE INTERACTIVE MEASUREMENT OF SURFACE-AREA AND VOLUME [J].
ALYASSIN, AM ;
LANCASTER, JL ;
DOWNS, JH ;
FOX, PT .
MEDICAL PHYSICS, 1994, 21 (06) :741-752
[3]   A STEREOPHOTOGRAMMETRIC METHOD FOR DETERMINING IN-SITU CONTACT AREAS IN DIARTHROIDAL JOINTS, AND A COMPARISON WITH OTHER METHODS [J].
ATESHIAN, GA ;
KWAK, SD ;
SOSLOWSKY, LJ ;
MOW, VC .
JOURNAL OF BIOMECHANICS, 1994, 27 (01) :111-124
[4]   ARTICULAR CONTACT IN A 3-DIMENSIONAL MODEL OF THE KNEE [J].
BLANKEVOORT, L ;
KUIPER, JH ;
HUISKES, R ;
GROOTENBOER, HJ .
JOURNAL OF BIOMECHANICS, 1991, 24 (11) :1019-1031
[5]   JOINT SPACE WIDTH MEASURES CARTILAGE THICKNESS IN OSTEOARTHRITIS OF THE KNEE - HIGH-RESOLUTION PLAIN FILM AND DOUBLE-CONTRAST MACRORADIOGRAPHIC INVESTIGATION [J].
BUCKLANDWRIGHT, JC ;
MACFARLANE, DG ;
LYNCH, JA ;
JASANI, MK ;
BRADSHAW, CR .
ANNALS OF THE RHEUMATIC DISEASES, 1995, 54 (04) :263-268
[6]   THE ROLE OF MECHANICAL LOADING HISTORIES IN THE DEVELOPMENT OF DIARTHRODIAL JOINTS [J].
CARTER, DR ;
WONG, M .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (06) :804-816
[7]   Determination of knee joint cartilage thickness using three-dimensional magnetic resonance chondro-crassometry (3D MR-CCM) [J].
Eckstein, F ;
Gavazzeni, A ;
Sittek, H ;
Haubner, M ;
Losch, A ;
Milz, S ;
Englmeier, KH ;
Schulte, E ;
Putz, R ;
Reiser, M .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (02) :256-265
[8]  
ECKSTEIN F, 1992, J ANAT, V180, P425
[9]   Magnetic resonance chondro-crassometry (MR CCM): A method for accurate determination of articular cartilage thickness [J].
Eckstein, F ;
Sittek, H ;
Gavazzeni, A ;
Schulte, E ;
Milz, S ;
Kiefer, B ;
Reiser, M ;
Putz, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (01) :89-96
[10]  
ENGLMEIER KH, 1994, P SOC PHOTO-OPT INS, V2164, P22, DOI 10.1117/12.174012