Automatic Learning Algorithm for the MD-Logic Artificial Pancreas System

被引:39
作者
Miller, Shahar [1 ]
Nimri, Revital [1 ]
Atlas, Eran [1 ]
Grunberg, Eli A. [1 ]
Phillip, Moshe [1 ,2 ]
机构
[1] Schneider Childrens Med Ctr Israel, Jesse Z & Sara Lea Shafer Inst Endocrinol & Diabe, Natl Ctr Childhood Diabet, IL-49202 Petah Tiqwa, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
关键词
TYPE-1; LOOP;
D O I
10.1089/dia.2010.0216
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Applying real-time learning into an artificial pancreas system could effectively track the unpredictable behavior of glucose-insulin dynamics and adjust insulin treatment accordingly. We describe a novel learning algorithm and its performance when integrated into the MD-Logic Artificial Pancreas (MDLAP) system developed by the Diabetes Technology Center, Schneider Children's Medical Center of Israel, Petah Tikva, Israel. Methods: The algorithm was designed to establish an initial patient profile using open-loop data (Initial Learning Algorithm component) and then make periodic adjustments during closed-loop operation (Runtime Learning Algorithm component). The MDLAP system, integrated with the learning algorithm, was tested in seven different experiments using the University of Virginia/Padova simulator, comprising adults, adolescents, and children. The experiments included simulations using the open-loop and closed-loop control strategy under nominal and varying insulin sensitivity conditions. The learning algorithm was automatically activated at the end of the open-loop segment and after every day of the closed-loop operation. Metabolic control parameters achieved at selected time points were compared. Results: The percentage of time glucose levels were maintained within 70-180 mg/dL for children and adolescents significantly improved when open-loop was compared with day 6 of closed-loop control (P < 0.0001) and remained unaltered for the adult group (P = 0.11) during nominal conditions. In varying insulin sensitivity conditions, the percentage of time glucose levels were below 70mg/dL was significantly reduced by approximately sevenfold (P < 0.001). These observations were correlated with significant reduction in the Low Blood Glucose Index (P < 0.001). Conclusions: The new algorithm was effective in characterizing the patient profiles from open-loop data and in adjusting treatment to provide better glycemic control during closed-loop control in both conditions. These findings warrant corroboratory clinical trials.
引用
收藏
页码:983 / 990
页数:8
相关论文
共 22 条
[1]   MD-Logic Artificial Pancreas System A pilot study in adults with type 1 diabetes [J].
Atlas, Eran ;
Nimri, Revital ;
Miller, Shahar ;
Grunberg, Eli A. ;
Phillip, Moshe .
DIABETES CARE, 2010, 33 (05) :1072-1076
[2]  
Bruttomesso Daniela, 2009, J Diabetes Sci Technol, V3, P1014
[3]  
Clarke William L, 2009, J Diabetes Sci Technol, V3, P1031
[4]  
Dassau E, 2011, INT J CLIN PRACT, V65, P20, DOI [10.1111/j.1742-1241.2010.02575.x, 10.1111/j.1742-1241.2009.02274.x]
[5]  
Dassau E, 2010, INT J CLIN PRACT, V166, P20
[6]   A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes [J].
El-Khatib, Firas H. ;
Russell, Steven J. ;
Nathan, David M. ;
Sutherlin, Robert G. ;
Damiano, Edward R. .
SCIENCE TRANSLATIONAL MEDICINE, 2010, 2 (27) :27ra27
[7]   Variation of Interstitial Glucose Measurements Assessed by Continuous Glucose Monitors in Healthy, Nondiabetic Individuals [J].
Fox, Larry A. ;
Beck, Roy W. ;
Xing, Dongyuan ;
Chase, H. Peter ;
Gilliam, Lisa K. ;
Hirsch, Irl ;
Kollman, Craig ;
Laffel, Lori ;
Lee, Joyce ;
Ruedy, Katrina J. ;
Tamborlane, William V. ;
Tansey, Michael ;
Wilson, Darrell M. .
DIABETES CARE, 2010, 33 (06) :1297-1299
[8]   Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial [J].
Hovorka, Roman ;
Allen, Janet M. ;
Elleri, Daniela ;
Chassin, Ludovic J. ;
Harris, Julie ;
Xing, Dongyuan ;
Kollman, Craig ;
Hovorka, Tomas ;
Larsen, Anne Mette F. ;
Nodale, Marianna ;
De Palma, Alessandro ;
Wilinska, Malgorzata E. ;
Acerini, Carlo L. ;
Dunger, David B. .
LANCET, 2010, 375 (9716) :743-751
[9]  
King Allen B, 2007, J Diabetes Sci Technol, V1, P42
[10]   Evaluation of a new measure of blood glucose variability in diabetes [J].
Kovatchev, Boris P. ;
Otto, Erik ;
Cox, Daniel ;
Gonder-Frederick, Linda ;
Clarke, William .
DIABETES CARE, 2006, 29 (11) :2433-2438