Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system

被引:72
作者
Kim, Myoung Joon [2 ]
Zheleznyak, Len [1 ]
MacRae, Scott
Tchah, Hungwon [2 ]
Yoon, Geunyoung [1 ]
机构
[1] Univ Rochester, Flaum Eye Inst, Inst Opt, Rochester, NY 14624 USA
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Ophthalmol, Seoul, South Korea
基金
美国国家卫生研究院;
关键词
CONTRAST SENSITIVITY; SPHERICAL-ABERRATION; IMAGE QUALITY; BILATERAL IMPLANTATION; GLARE DISABILITY; EYES; TECNIS; DESIGN; RESTOR; REZOOM;
D O I
10.1016/j.jcrs.2011.03.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: TO evaluate spherical aberration and through-focus optical performances of 5 presbyopia-correcting and 2 monofocal intraocular lenses (IOLs). SETTING: Flaum Eye Institute, University of Rochester, Rochester, New York, USA. DESIGN: Experimental study. METHODS: Five presbyopia-correcting IOLs (Restor +4D SN6AD3, Restor +3D SN6AD1, Rezoom NXG1, Tecnis multifocal ZM900, Crystalens HD500) were tested using an optical bench system consisting of a model eye, a high-resolution Hartmann-Shack wavefront sensor, and an image-capturing device. Two monofocal IOLs (Sofport AO LI60AOV, Acrysof SN60AT) were measured for comparison. No accommodation was simulated. The spherical aberration profiles of each IOL were measured using the wavefront sensor. Through-focus performance was evaluated by calculating cross-correlation coefficients and comparing the likenesses of captured images of a resolution target and a perfect reference image. RESULTS: With a 5.0 mm entrance pupil, the SN6AD3, SN6AD1, ZM900, NXG1, and HD500 IOLs had spherical aberration of -0.18 mu m, -0.14 mu m, -0.15 mu m, -0.07 mu m, and -0.01 mu m, respectively. Distance image quality was poorer with multifocal and accommodating IOLs than with monofocal IOLs. All multifocal IOLs had effective distance and near image quality but had a loss in intermediate image quality. The HD 500 accommodating IOL had decreased distance image quality and slightly increased depth of focus compared with the monofocal IOLs because of the bispheric design. CONCLUSIONS: The presbyopia-correcting IOLs had different optical characteristics, including spherical aberration profile and through-focus performance. An accurate understanding of the optical characteristics of individual IOLs is essential to selecting the best presbyopia-correcting IOL and thus improving cataract surgery outcomes.
引用
收藏
页码:1305 / 1312
页数:8
相关论文
共 33 条
[1]   Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: A multicenter randomized study [J].
Bellucci, R ;
Scialdone, A ;
Buratto, L ;
Morselli, S ;
Chierego, C ;
Criscuoli, A ;
Moretti, G ;
Piers, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (04) :712-717
[2]  
Bellucci R, 2005, J CATARACT REFR SURG, V31, P712
[3]   Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models [J].
Castillo-Gomez, Alfredo ;
Carmona-Gonzalez, David ;
Maria Martinez-de-la-Casa, Jose ;
Palomino-Bautista, Carlos ;
Garcia-Feijoo, Julian .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07) :1244-1250
[4]   Optical performance measurement and night driving simulation of ReSTOR, ReZoom, and Tecnis multifocal intraocular lenses in a model eye [J].
Choi, Junoh ;
Schwiegerling, Jim .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) :218-222
[6]  
GIMBEL HV, 1991, OPHTHALMOLOGY, V98, P881
[7]   Presbyopia and the optical changes in the human crystalline lens with age [J].
Glasser, A ;
Campbell, MCW .
VISION RESEARCH, 1998, 38 (02) :209-229
[8]  
Holladay JT, 2002, J REFRACT SURG, V18, P683
[9]   Optimizing distance image quality of an aspheric multifocal intraocular lens using a comprehensive statistical design approach [J].
Hong, Xin ;
Zhang, Xiaoxiao .
OPTICS EXPRESS, 2008, 16 (25) :20920-20934
[10]  
International Organization for Standardization, 1999, 119792 ISO