In-vivo retinal imaging with off-axis full-field time-domain optical coherence tomography

被引:35
|
作者
Sudkamp, Helge [1 ,2 ]
Koch, Peter [1 ]
Spahr, Hendrik [1 ,2 ]
Hillmann, Dierck [3 ]
Franke, Gesa [1 ,2 ]
Muenst, Michael [1 ]
Reinholz, Fred [1 ,2 ]
Birngruber, Reginald [1 ,2 ]
Huettmann, Gereon [1 ,2 ,4 ]
机构
[1] Med Laser Ctr Lubeck GmbH, Peter Monnik Weg 4, D-23562 Lubeck, Germany
[2] Univ Lubeck, Inst Biomed Opt, Peter Monnik Weg 4, D-23562 Lubeck, Germany
[3] Thorlabs GmbH, Maria Goeppert Str 9, D-23562 Lubeck, Germany
[4] Member German Ctr Lung Res DZL, ARCN, D-35392 Giessen, Germany
关键词
ANTERIOR; OCT;
D O I
10.1364/OL.41.004987
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
With a simple setup, mainly composed of a low coherence light source and a camera, full-field optical coherence tomography (FF-OCT) allows volumetric tissue imaging. However, fringe washout constrains its use in retinal imaging. Here, we present a novel motion-insensitive approach to FF-OCT, which introduces path-length differences between the reference and the sample light in neighboring pixels using an off-axis reference beam. The temporal carrier frequency in scanned time-domain OCT is replaced by a spatial carrier frequency. Volumetric in-vivo FF-OCT measurements of the human retina were acquired in only 1.3 s, comparable to the acquisition times of current clinically used OCT devices. (C) 2016 Optical Society of America
引用
收藏
页码:4987 / 4990
页数:4
相关论文
共 50 条
  • [21] Multimode fiber enables control of spatial coherence in Fourier-domain full-field optical coherence tomography for in vivo corneal imaging
    Auksorius, Egidijus
    Borycki, Dawid
    Wojtkowski, Maciej
    OPTICS LETTERS, 2021, 46 (06) : 1413 - 1416
  • [22] Imaging-AOTF-based full-field spectral-domain optical coherence tomography
    Machikhin, Alexander
    Viskovatykh, Alexander
    Pozhar, Vitold
    Burmak, Ludmila
    SARATOV FALL MEETING 2014: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XVI; LASER PHYSICS AND PHOTONICS XVI; AND COMPUTATIONAL BIOPHYSICS, 2015, 9448
  • [23] In vivo high resolution human corneal imaging using full-field optical coherence tomography
    Mazlin, Viacheslav
    Xiao, Peng
    Dalimier, Eugenie
    Grieve, Kate
    Irsch, Kristina
    Sahel, Jost-Alain
    Fink, Mathias
    Boccara, A. Claude
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (02): : 557 - 568
  • [24] In vivo and in situ cellular imaging full-field optical coherence tomography with a rigid endoscopic probe
    Latrive, Anne
    Boccara, A. Claude
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (10): : 2897 - 2904
  • [25] In vivo imaging through the entire thickness of human cornea by full-field optical coherence tomography
    Mazlin, Viacheslav
    Xiao, Peng
    Dalimier, Eugenie
    Grieve, Kate
    Irsch, Kristina
    Sahel, Jose
    Fink, Mathias
    Boccara, Claude
    OPHTHALMIC TECHNOLOGIES XXVIII, 2018, 10474
  • [26] Influence of static and dynamic ocular aberrations on full-field optical coherence tomography for in vivo high-resolution retinal imaging
    Cai, Yao
    Thouvenin, Olivier
    Grieve, Kate
    Mece, Pedro
    OPTICS LETTERS, 2024, 49 (09) : 2209 - 2212
  • [27] Research on full-field optical coherence tomography
    School of Electronic Engineering and Optoelectronic Technology, Nanjing University of Science and Technology, Nanjing
    210094, China
    不详
    214041, China
    Tongxin Xuebao, 12 (121-127):
  • [28] A method of improving imaging quality of full-field optical coherence tomography
    Zhu, Yue
    Gao, Wanrong
    Guo, Yingcheng
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35 (05):
  • [29] Human graft cornea imaging with full-field optical coherence tomography
    Ghouali, Wajdene
    Grieve, Kate
    Sandali, Otman
    Basli, Elena
    Bullet, Julien
    Laroche, Laurent
    Borderie, Vincent
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [30] Full-field optical coherence tomography using a fibre imaging bundle
    Ford, H. D.
    Tatam, R. P.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079