Axial Load Response of Ultra-High-Strength Concrete Columns and High-Strength Reinforcement

被引:35
作者
Shin, Hyun-Oh [1 ]
Yoon, Young-Soo [2 ]
Cook, William D. [1 ]
Mitchell, Denis [1 ]
机构
[1] McGill Univ, Dept Civil Engn & Appl Mech, Montreal, PQ, Canada
[2] Korea Univ, Sch Civil Environm & Architectural Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
axial load; columns; confinement; high-strength longitudinal reinforcement; high-strength transverse reinforcement; ultra-high-strength concrete; CONCENTRIC COMPRESSION; CONFINEMENT MODEL; BEHAVIOR;
D O I
10.14359/51688063
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Eight ultra-high-strength concrete (UHSC) square columns were constructed and tested to investigate the effects of yield strength of transverse (f(yh) approximate to 550 and 800 MPa [79.8 and 116.0 ksi]) and longitudinal reinforcement (f(yh) approximate to 480 and 640 MPa [69.6 and 92.8 ksi]) on axial load response. The UHSC had compressive strengths varying from 185 to 200 MPa (26.8 to 29.0 ksi). The effects of using high-strength transverse reinforcement with two different configurations and amounts were evaluated. For a constant amount of confinement reinforcement, high-strength transverse reinforcement improves the performance of well-confined UHSC columns in terms of strength, post-peak deformability, and toughness, provided that the hoops are detailed with proper end anchorage (135-degree seismic hooks). The use of high-strength transverse reinforcement was also effective in reducing steel congestion for UHSC columns. The effects of using high-strength longitudinal reinforcement in UHSC columns were also studied. It was determined that the combination of high-strength longitudinal reinforcement and UHSC results in yielding of this reinforcement. However, for typical longitudinal reinforcement ratios, the benefit of using high-strength longitudinal steel is limited due to the relatively small contribution of this reinforcement to the strength of UHSC columns and the early cover spalling of UHSC.
引用
收藏
页码:325 / 336
页数:12
相关论文
共 27 条
[1]  
ACI Innovation Task Group 4 and Other Contributors, 2007, ITG43R07 ACI
[2]  
[Anonymous], 2014, Design of concrete structures
[3]  
[Anonymous], 2014, C3939M14A ASTM
[4]  
[Anonymous], 2011, Building Code Requirements for Structural Concrete (ACI 318-11) and Commentary
[5]  
[Anonymous], A1035A1035M14 ASTM
[6]  
[Anonymous], 2006, 31012 NZS
[7]  
[Anonymous], 2006, NZS 3101
[8]   Behavior of Rectangular Columns Constructed with SCC and Steel Fibers [J].
Aoude, Hassan ;
Hosinieh, Milad Mohammadi ;
Cook, William D. ;
Mitchell, Denis .
JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (08)
[9]  
ASTM, 2010, ASTM C78/C78M-10
[10]  
AZIZINAMINI A, 1994, ACI STRUCT J, V91, P336