Efficacy of a remote based computerised visual acuity measurement

被引:18
作者
Srinivasan, Krithica [1 ]
Ramesh, S. Ve [1 ]
Babu, Noushad [1 ]
Sanker, Nijil [1 ]
Ray, Avik [1 ]
Karuna, S. M. [1 ]
机构
[1] Manipal Univ, Manipal Coll Allied Hlth Sci, Dept Optometry, Manipal 576104, Karnataka, India
关键词
IMPAIRMENT; LOGMAR;
D O I
10.1136/bjophthalmol-2012-301751
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To determine the efficacy of a remotely operated computer-based logarithmic (logMAR) visual acuity chart. Methods Visual acuity was tested using a laptop or computer-based logMAR chart (COMPlog) for all subjects by two different methods. The methods differed by the physical presence and absence (remote) of an optometrist and in the mode of instructions provided. Remote access was obtained through the internet, using Teamviewer software to control the system linked to COMPlog and instructions were provided by telephone. The order of measurements and the eye to be tested was randomised. logMAR visual acuity and time taken were recorded. A questionnaire was used to assess the participant's feedback. Results Intraclass correlation for visual acuity between the two methods (alpha=0.964, 95% CI 0.937 to 0.979). There was no statistically significant difference (p=0.648) in the median visual acuity measurement between the two methods (median difference 0.00, IQR 0.20 logMAR). The time taken between the two methods was not statistically significant (p=0.457). There was no significant difference in the responses to the questionnaire between the study methods (p=0.119). Conclusions Tele (remotely controlled) visual acuity measurement is as reliable as that measured with the physical presence of an optometrist.
引用
收藏
页码:987 / 990
页数:4
相关论文
共 13 条
[1]   Comparison of visual acuity in macular degeneration patients measured with Snellen and Early Treatment Diabetic Retinopathy Study Charts [J].
Falkenstein, Iryna A. ;
Cochran, Denine E. ;
Azen, Stanley P. ;
Dustin, Laurie ;
Tammewar, Ajay M. ;
Kozak, Igor ;
Freeman, William R. .
OPHTHALMOLOGY, 2008, 115 (02) :319-323
[2]   Visual impairment: a correctable global problem [J].
Holden, BA ;
Rao, GN ;
Knox, KM ;
Sulaiman, SM .
MEDICAL JOURNAL OF AUSTRALIA, 1997, 167 (07) :351-352
[3]   Changing from Snellen to LogMAR: debate or delay? [J].
Hussain, B ;
Saleh, GM ;
Sivaprasad, S ;
Hammond, CJ .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (01) :6-8
[4]   Validation of a computerised logMAR visual acuity measurement system (COMPlog): comparison with ETDRS and the electronic ETDRS testing algorithm in adults and amblyopic children [J].
Laidlaw, D. A. H. ;
Tailor, V. ;
Shah, N. ;
Atamian, S. ;
Harcourt, C. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (02) :241-244
[5]   VALIDITY AND RELIABILITY OF VISUAL-ACUITY MEASUREMENTS [J].
LOVIEKITCHIN, JE .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1988, 8 (04) :363-370
[6]  
Monica Raja BS, 2011, SCI J MED VIS RES FO, VXXIX, P41
[7]   The tele-screening model for diabetic retinopathy:: Evaluating the influence of mydriasis on the gradability of a single-field 45° digital fundus image [J].
Raman, Rajiv ;
Rani, Padmaja Kumari ;
Mahajan, Sheshadri ;
Paul, Pradeep ;
Gnanamoorthy, P. ;
Krishna, M. S. ;
Sharma, Tarun .
TELEMEDICINE JOURNAL AND E-HEALTH, 2007, 13 (05) :597-602
[8]   Patient satisfaction with tele-ophthalmology versus ophthalmologist-based screening in diabetic retinopathy [J].
Rani, Padmaja Kumari ;
Raman, Rajiv ;
Manikandan, Muthu ;
Mahajan, Seshadri ;
Paul, Pradeep G. ;
Sharma, Tarun .
JOURNAL OF TELEMEDICINE AND TELECARE, 2006, 12 (03) :159-160
[9]  
Resnikoff S, 2004, B WORLD HEALTH ORGAN, V82, P844
[10]   Determinants of glaucoma awareness and knowledge in urban Chennai [J].
Sathyamangalam, Ramesh Ve ;
Paul, Pradeep G. ;
Ronnie, George ;
Baskaran, Mani ;
Hemamalini, Arvind ;
Madan, Raj, V ;
Augustian, J. ;
Prema, Raju ;
Vijaya, Lingam .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2009, 57 (05) :355-360