Wireless remote monitoring of reconstructed 12-lead ECGs after ablation for atrial fibrillation using a hand-held device

被引:7
作者
Gussak, Ihor [1 ]
Vukajlovic, Dejan [2 ]
Vukcevic, Vladan [3 ]
George, Samuel [1 ]
Bojovic, Bosko [4 ]
Hadzievski, Ljupco [4 ]
Simic, Goran [1 ]
Stojanovic, Bojan [5 ]
Angelkov, Lazar [5 ]
Panescu, Dorin [1 ]
机构
[1] NewCardio Inc, Santa Clara, CA USA
[2] Dedinje Cardiovasc Inst, Belgrade, Serbia
[3] Clin Ctr Serbia, Belgrade, Serbia
[4] Vinca Inst, Belgrade, Serbia
[5] Klin Petkov, Belgrade, Serbia
关键词
Wireless remote monitoring; 12-lead ECG; Ablation; Atrial fibrillation; Hand-held monitor; Holter monitoring; PULMONARY VEIN ISOLATION; ANTITACHYCARDIA PACEMAKERS; TEMPORAL VARIABILITY; SAMPLE-SIZE; FOLLOW-UP; BRADYCARDIA; RECURRENCE; BURDEN; PATTERNS; DURATION;
D O I
10.1016/j.jelectrocard.2011.09.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Atrial fibrillation (AF) surveillance using a wireless handheld monitor capable of 12-lead electrocardiogram reconstruction was performed, and arrhythmia detection rate was compared with serial Holter monitoring. Methods: Twenty-five patients were monitored after an AF ablation procedure using the hand-held monitor for 2 months immediately after and then for 1 month approximately 6 months postablation. All patients underwent 12-lead 24-hour Holter monitoring at 1, 2, and 6 months postablation. Results: During months 1-2, 425 of 2942 hand-held monitor transmissions from 21 of 25 patients showed AF/atrial flutter (Afl). The frequency of detected arrhythmias decreased by month 6 to 85/1128 (P < .01) in 15 of 23 patients. Hotter monitoring diagnosed AF/Afl in 8 of 25 and 7 of 23 patients at months 1-2 and month 6, respectively (P < .01 compared with wireless hand-held monitor). Af/Afl diagnosis by wireless monitoring preceded Holler detection by an average of 24 days. Conclusions: Wireless monitoring with 12-lead electrocardiogram reconstruction demonstrated reliable AF/Afl detection that was more sensitive than serial 12-lead 24-hour Holter monitoring. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:129 / 135
页数:7
相关论文
共 32 条
  • [31] Optimization of Using Multiple Machine Learning Approaches in Atrial Fibrillation Detection Based on a Large-Scale Data Set of 12-Lead Electrocardiograms: Cross-Sectional Study
    Chuang, Beau Bo-Sheng
    Yang, Albert C.
    JMIR FORMATIVE RESEARCH, 2024, 8
  • [32] Twenty-Four-Hour Holter Monitor Follow-Up Does Not Provide Accurate Heart Rhythm Status After Surgical Atrial Fibrillation Ablation Therapy Up to 12 Months Experience With a Novel Permanently Implantable Heart Rhythm Monitor Device
    Hanke, Thorsten
    Charitos, Efstratios I.
    Stierle, Ulrich
    Karluss, Antje
    Kraatz, Ernst
    Graf, Bernhard
    Hagemann, Axel
    Misfeld, Martin
    Sievers, Hans H.
    CIRCULATION, 2009, 120 (11) : S177 - S184