A New Topology of Higher Order Power Filter for Single-Phase Grid-Tied Voltage-Source Inverters

被引:39
作者
Anzalchi, Arash [1 ]
Moghaddami, Masood [1 ]
Moghaddasi, Amir [1 ]
Sarwat, Arif I. [1 ]
Rathore, Akshay K. [2 ]
机构
[1] Florida Int Univ, Dept Elect & Comp Engn, Miami, FL 33174 USA
[2] Natl Univ Singapore, Dept Elect & Comp Engn, Singapore 119077, Singapore
基金
美国国家科学基金会;
关键词
Grid-tied voltage-source inverter (VSI); harmonics; LCL filter; LLCL filter; L(LCL)(2) filter; power quality; switching frequency; LCL; DESIGN; OPTIMIZATION; PERFORMANCE; MODE;
D O I
10.1109/TIE.2016.2594222
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In order to reduce the influence of the grid harmonic currents and voltages, harmonic compensation is regularly implemented for a grid-tied inverter. In this study, a new topology of a higher order power filter for singlephase grid-tied voltage-source inverters, named L(LCL)(2), is presented. The subscript is added to the name to prevent confusion with the LLCL filter. In the proposed design, the inverter side inductance is divided into three parts, and the grid side inductor is removed. Also, an additional resonant branch at the double of the switching frequency is added to the traditional LLCL filter to attenuate high-frequency harmonics. The overall inductance of the recommended filter is smaller than the LLCL filter. A comparative study and discussions on the subject of the traditional LLCL filter and the proposed L(LCL)(2) filter have been conducted and assessed through an experimental hardware implementation on a 700 W, 120 V/60 Hz single-phase grid-tied inverter. Furthermore, a straightforward engineering design benchmark is suggested to discover parameters of the L(LCL)(2) filter. Moreover, stability analysis, loss analysis and an optimization of the L(LCL)(2) filter parameters have been conducted in this study. The analysis shows that in comparison with the LLCL filter, the L(LCL)(2) filter not only has lower voltage drop and less total inductor size, but also has improved performance in decreasing high-order current harmonics.
引用
收藏
页码:7511 / 7522
页数:12
相关论文
共 28 条
  • [1] Dual-mode time-sharing sinewave-modulation soft, switching boost full-bridge one-stage power conditioner without electrolytic capacitor DC link
    Ahmed, Nabil A.
    Lee, Hyun Woo
    Nakaoka, Mutsuo
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (03) : 805 - 813
  • [2] [Anonymous], 2011, P 2011 14 EUR C POW
  • [3] [Anonymous], 2014, IEEE Std 519-2014, P1
  • [4] [Anonymous], IEEE T IND IN PRESS
  • [5] Anzalchi A, 2015, SOUTHEASTCON 2015, P1, DOI DOI 10.1109/SECON.2015.7132988
  • [6] Model-based generation of low distortion currents in grid-coupled PWM-Inverters using an LCL output filter
    Bolsens, Bruno
    De Brabandere, Karel
    Van den Keybus, Jeroen
    Driesen, Johan
    Belmans, Ronnie
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2006, 21 (04) : 1032 - 1040
  • [7] Full-State Feedback Equivalent Controller for Active Damping in LCL-Filtered Grid-Connected Inverters Using a Reduced Number of Sensors
    Busada, Claudio A.
    Gomez Jorge, Sebastian
    Solsona, Jorge A.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (10) : 5993 - 6002
  • [8] Filter Optimization for Grid Interactive Voltage Source Inverters
    Channegowda, Parikshith
    John, Vinod
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (12) : 4106 - 4114
  • [9] Implement Optimal Vector Control for LCL-Filter-Based Grid-Connected Converters by Using Recurrent Neural Networks
    Fu, Xingang
    Li, Shuhui
    Jaithwa, Ishan
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (07) : 4443 - 4454
  • [10] Analysis and Comparison of Peak-to-Peak Current Ripple in Two-Level and Multilevel PWM Inverters
    Grandi, Gabriele
    Loncarski, Jelena
    Dordevic, Obrad