Refrigerant charge in refrigerating systems and strategies of charge reduction

被引:131
|
作者
Poggi, F. [1 ]
Macchi-Tejeda, H. [1 ]
Leducq, D. [1 ]
Bontemps, A. [2 ]
机构
[1] Irstea, UR GPAN, F-92163 Antony, France
[2] LEGI GREThE CEA, F-38054 Grenoble, France
关键词
refrigeration system; compression system; optimization; refrigerant charge; calculation; design; refrigeration circuit; COP; TEWI;
D O I
10.1016/j.ijrefrig.2007.05.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
For some years, European regulation concerning refrigerating systems has become more and more severe. Because of their design and technology, refrigeration units cannot avoid refrigerant leaks, and can thus have a harmful impact on the environment. Many studies aimed at minimizing the charge in a refrigerating machine were thus developed. On a global level, reduction of refrigerant charges must not affect energy aspects while respecting environmental constraints [Montreal 1987, Kyoto 1997]. The architecture and refrigerant charge distribution in the systems are of particular importance; their analyses permit the determination of the target elements and thus define those in which the refrigerant charge could be reduced (heat exchangers, liquid pipes, receivers, ...). This paper presents a review of the refrigerant charge studies in a refrigerating plant (methodologies of charge measurement, void fraction correlations and characteristic values for various technologies). It also evaluates the influence of the refrigerant charge on the coefficient of performance (COP) and on the cooling capacity. Finally, it inventories the different means that allow the charge in a refrigerating system to be minimized. (C) 2007 Elsevier Ltd and IIR.
引用
收藏
页码:353 / 370
页数:18
相关论文
共 50 条
  • [21] Performance evaluation of a virtual refrigerant charge sensor
    Kim, Woohyun
    Braun, James E.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 1130 - 1141
  • [22] Hydrocarbon refrigerant charge limits for quiescent rooms
    Colbourne, D.
    Suen, K. O.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 125 : 75 - 83
  • [23] Refrigerant charge fault diagnosis strategy for VRF systems based on stacking ensemble learning
    Zhang, Li
    Cheng, Yahao
    Zhang, Jianxin
    Chen, Huanxin
    Cheng, Hengda
    Gou, Wei
    BUILDING AND ENVIRONMENT, 2023, 234
  • [24] Using CO2 To Reduce Refrigerant Charge
    Pearson, S. Forbes
    ASHRAE JOURNAL, 2012, 54 (10) : 38 - +
  • [25] Development, Evaluation, and Demonstration of a Virtual Refrigerant Charge Sensor
    Li, Haorong
    Braun, James E.
    HVAC&R RESEARCH, 2009, 15 (01): : 117 - 136
  • [26] Determination of a Vapor Compression Refrigeration System Refrigerant Charge
    Yang Chun-Xin
    Dang Chao-Bin (Institute of Air Conditioning and Refrigeration Engineering
    Journal of Thermal Science, 1995, (03) : 162 - 168
  • [27] NEW FLAMMABLE REFRIGERANT CHARGE LIMIT IN COMMERCIAL REFRIGERATION
    Zgliczynski, Marek
    COMPRESSORS 2021 - 10TH IIR CONFERENCE ON COMPRESSORS AND REFRIGERANTS, 2021,
  • [28] Using CO2 to Reduce Refrigerant Charge
    Walker, Steve
    ASHRAE JOURNAL, 2013, 55 (01) : 16 - 16
  • [29] Low Refrigerant Charge With a Focus on Microchannel Heat Exchangers
    Hrnjak, Pega
    ASHRAE/NIST REFRIGERANTS CONFERENCE, 2012, : 272 - 283
  • [30] Defrost improvement by heat pump refrigerant charge compensating
    Zhiyi, Wang
    Xinmin, Wang
    Zhiming, Dong
    APPLIED ENERGY, 2008, 85 (11) : 1050 - 1059