Refrigerant charge in refrigerating systems and strategies of charge reduction

被引:141
作者
Poggi, F. [1 ]
Macchi-Tejeda, H. [1 ]
Leducq, D. [1 ]
Bontemps, A. [2 ]
机构
[1] Irstea, UR GPAN, F-92163 Antony, France
[2] LEGI GREThE CEA, F-38054 Grenoble, France
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2008年 / 31卷 / 03期
关键词
refrigeration system; compression system; optimization; refrigerant charge; calculation; design; refrigeration circuit; COP; TEWI;
D O I
10.1016/j.ijrefrig.2007.05.014
中图分类号
O414.1 [热力学];
学科分类号
摘要
For some years, European regulation concerning refrigerating systems has become more and more severe. Because of their design and technology, refrigeration units cannot avoid refrigerant leaks, and can thus have a harmful impact on the environment. Many studies aimed at minimizing the charge in a refrigerating machine were thus developed. On a global level, reduction of refrigerant charges must not affect energy aspects while respecting environmental constraints [Montreal 1987, Kyoto 1997]. The architecture and refrigerant charge distribution in the systems are of particular importance; their analyses permit the determination of the target elements and thus define those in which the refrigerant charge could be reduced (heat exchangers, liquid pipes, receivers, ...). This paper presents a review of the refrigerant charge studies in a refrigerating plant (methodologies of charge measurement, void fraction correlations and characteristic values for various technologies). It also evaluates the influence of the refrigerant charge on the coefficient of performance (COP) and on the cooling capacity. Finally, it inventories the different means that allow the charge in a refrigerating system to be minimized. (C) 2007 Elsevier Ltd and IIR.
引用
收藏
页码:353 / 370
页数:18
相关论文
共 94 条
[1]  
[Anonymous], ASHRAE T
[2]  
Armand A.A., 1946, Izv. Vses. Teplotekh., V1, P16
[3]  
*ASHRAE, 1990, ASHRAE HDB
[4]  
AZZOUZ K, 2003, UNPUB CONCEPTION OPT
[5]  
BARNES PR, 2002, ZERO LEAKAGE MINIMUM
[6]   TRANSIENT MASS-FLOW RATE OF A RESIDENTIAL AIR-TO-AIR HEAT-PUMP [J].
BELTH, MI ;
GRZYMALA, TE ;
TREE, DR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1988, 11 (05) :298-304
[7]  
BELTH ML, 1986, ASHRAE T 1B, V92, P843
[8]   Refrigerant mass charge distribution in a domestic refrigerator.: Part I:: Transient conditions [J].
Björk, E ;
Palm, B .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :829-837
[9]   Refrigerant mass charge distribution in a domestic refrigerator.: Part II:: Steady state conditions [J].
Björk, E ;
Palm, B .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :866-871
[10]   A simple technique for refrigerant mass measurement [J].
Björk, E .
APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) :1115-1125