Outcomes of Solo Smart valve in a single-center experience of 270 patients

被引:1
作者
Liu, Hao [1 ,2 ]
Khani-Hanjani, Abbas [1 ]
Yang, Siyuan [1 ,3 ]
Wang, Wei [1 ]
Sidhu, Surita [4 ]
Mullen, John [1 ]
Modry, Dennis [1 ]
Wang, Shaohua [1 ]
机构
[1] Univ Alberta, Mazankowski Alberta Heart Inst, Div Cardiac Surg, Edmonton, AB, Canada
[2] Shanghai Jiao Tong Univ, Xinhua Hosp, Sch Med, Cardiothorac Dept, Shanghai, Peoples R China
[3] Guiyang Med Coll, Affiliated Hosp, Dept Cardiac Surg, Guiyang, Guizhou, Peoples R China
[4] Univ Alberta, Mazankowski Alberta Heart Inst, Dept Anesthesiol & Pain Med, Edmonton, AB, Canada
关键词
Transcatheter aortic valve replacement; Bioprosthesis; Cardiac surgical procedures; PERICARDIAL STENTLESS VALVE; AORTIC-VALVE; LONG-TERM; PROSPECTIVE MULTICENTER; PACEMAKER IMPLANTATION; CLINICAL IMPACT; FOLLOW-UP; REPLACEMENT; BIOPROSTHESIS; MISMATCH;
D O I
10.23736/S0021-9509.18.10165-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The Solo Smart pericardial aortic valve has been widely used in Europe as an option for aortic valve replacement (AVR). We are reporting early and midterm clinical outcomes of AVR with the Solo Smart valve in a single North America center. METHODS: This is a retrospective study of 270 consecutive patients who had AVR at Mazankowski Alberta Heart Institute from February 2011 to March 2015. Follow-up and echocardiographic data were collected retrospectively from electronic and paper charts. Univariate and multivariate analysis were performed to evaluate the results. RESULTS: The mean age was 71.2 +/- 10.0 years, 67.4% were male, and 793% had combined procedures. Mean STS Score was 4.18 +/- 3.91. Early mortality was 3.7% for the entire group and 0% for isolated AVR group. Mean cross-clamp time for isolated AVR and AVR with concomitant procedure was 70.8 +/- 12.7 min and 117.0+45.0 min, respectively. Permanent pacemaker implantation was necessary in 2.2% of patients. Echocardiography demonstrated a reduction in mean gradients from 40.8 +/- 17.4 mmHg to 7.6 +/- 3.7 mmHg and peak gradient from 72.5 +/- 48.8 mmHg to 15.5 +/- 7.5 mmHg. The 1-, 3-, and 5-year overall survival was 93.0%, 86.5% and 75.9%, respectively. At 5 years, freedom from valve-related death was 92.4%, freedom from structural valve deterioration and freedom from aortic valve reoperation were 96.4% and 98%. respectively. CONCLUSIONS: The Solo Smart valve is safe and has excellent hemodynamic performance. Aortic valve reoperation and rates of valve-related adverse events during midterm follow-up were low.
引用
收藏
页码:633 / 639
页数:7
相关论文
共 28 条
[11]   Long-term requirement for pacemaker implantation after cardiac valve replacement surgery [J].
Leyva, Francisco ;
Qiu, Tian ;
McNulty, David ;
Evison, Felicity ;
Marshall, Howard ;
Gasparini, Maurizio .
HEART RHYTHM, 2017, 14 (04) :529-534
[12]   Does the use of stentless aortic valves in a subcoronary position prevent patient-prosthesis mismatch for small aortic annulus? [J].
Lopez, Stephane ;
Mathieu, Patrick ;
Pibarot, Philippe ;
Mohammadi, Siamak ;
Dagenais, Francois ;
Voisine, Pierre ;
Dumesnil, Jean ;
Doyle, Daniel .
JOURNAL OF CARDIAC SURGERY, 2008, 23 (04) :331-335
[13]   In patients undergoing aortic valve replacement, what factors predict the requirement for permanent pacemaker implantation? [J].
Matthews, Iain G. ;
Fazal, Iftikhar A. ;
Bates, Matthew G. D. ;
Turley, Andrew J. .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 12 (03) :475-479
[14]   Long-Term Clinical and Echocardiographic Follow-Up of the Freestyle Stentless Aortic Bioprosthesis [J].
Mohammadi, Siamak ;
Tchana-Sato, Vincent ;
Kalavrouziotis, Dimitri ;
Voisine, Pierre ;
Doyle, Daniel ;
Baillot, Richard ;
Sponga, Sandro ;
Metras, Jacques ;
Perron, Jean ;
Dagenais, Francois .
CIRCULATION, 2012, 126 (11) :S198-S204
[15]   Prosthesis-patient mismatch: definition, clinical impact, and prevention [J].
Pibarot, P. ;
Dumesnil, J. G. .
HEART, 2006, 92 (08) :1022-1029
[16]   Severe Thrombocytopenia and Its Clinical Impact After Implant of the Stentless Freedom Solo Bioprosthesis [J].
Pozzoli, Alberto ;
De Maat, Gijs Eduard ;
Hillege, Hans L. ;
Boogaard, Jacob J. A. ;
Natour, Eshan ;
Mariani, Massimo Alessandro .
ANNALS OF THORACIC SURGERY, 2013, 96 (05) :1581-1586
[17]   Single-suture line placement of a pericardial stentless valve [J].
Repossini, A ;
Kotelnikov, I ;
Bouchikhi, R ;
Torre, T ;
Passaretti, B ;
Parodi, O ;
Arena, V .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (05) :1265-1269
[18]   Pericardial Stentless Valve for Aortic Valve Replacement: Long-Term Results [J].
Repossini, Alberto ;
Fischlein, Theodor ;
Santarpino, Giuseppe ;
Schaefer, Christina ;
Claus, Benjamin ;
Passaretti, Bruno ;
Di Bacco, Lorenzo ;
Giroletti, Laura ;
Bisleri, Gianluigi ;
Muneretto, Claudio ;
Grubitzsch, Herko .
ANNALS OF THORACIC SURGERY, 2016, 102 (06) :1956-1965
[19]   Early clinical and haemodynamic results after aortic valve replacement with the Freedom SOLO bioprosthesis (experience of Italian multicenter study) [J].
Repossini, Alberto ;
Rambaldini, Manfredo ;
Lucchetti, Vincenzo ;
Da Col, Uberto ;
Cesari, Francesco ;
Mignosa, Carmelo ;
Picano, Eugenio ;
Glauber, Mattia .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (05) :1104-1110
[20]   Permanent pacemaker implantation after aortic valve replacement: Long-term dependency or rhythm recovery? [J].
Ribeiro, Vania ;
Garcia, Raquel Mota ;
Frutuoso, Cecilia ;
Melao, Filipa ;
Pereira, Marta ;
Pinho, Paulo ;
Maciel, Maria Julia .
REVISTA PORTUGUESA DE CARDIOLOGIA, 2015, 34 (09) :529-533