Ultrasonic and Radiographic Quantification of Palmar Angulation in Metacarpal IV and V Neck Fractures

被引:13
作者
Hennecke, B. [1 ]
Kluge, S. [2 ]
Kreutziger, J. [3 ]
Jenzer, A. [1 ]
Voegelin, E. [1 ]
机构
[1] Univ Spital Bern, Klin Plast & Handchirurg, Inselspital, CH-3010 Bern, Switzerland
[2] Zentrum Handchirurg, Schulthess Klin, Zurich, Switzerland
[3] Med Univ Innsbruck, Klin Anasthesie & Allgemeine Intens Med, Landeskrankenanstalten, Innsbruck, Austria
关键词
metacarpal neck fracture; palmar angulation; ultrasound; x-ray; 5TH METACARPAL; FUNCTIONAL TREATMENT; BOXERS FRACTURES;
D O I
10.1055/s-0030-1267974
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose/Background: Therapy of metacarpal neck fractures depending on radiographically measured palmar angulation is discussed controversially in the literature. Some authors describe normal hand function of malunited metacarpal neck fractures with a palmar angulation up to 70 degrees ; others define 30 degrees as the uppermost limit to maintain normal hand function. However, the methods of measuring palmar angulation are not clearly defined. Here, we present a new method to measure palmar angulation using ultrasound. The aim of this prospective study is to compare the radiographic methods of measuring palmar angulation with the ultrasound method. Patients/Material and Method: 20 patients with a neck fracture of the metacarpals IV or V were treated either conservatively or operatively. 2 weeks after trauma or operation, an x-ray was performed. 2 examiners measured the palmar angulation on the oblique and lateral projections using 2 different methods (medullary canal and dorsal cortex methods). At the same time, the 2 examiners performed measurements of palmar angulation using ultrasound. The measurements obtained with the different methods as well as by the 2 examiners at 2 different terms were compared. Intra- and interobserver reliability of each method was calculated, and for the ultrasound method a test for accuracy of the measured angles was performed. Results: Depending on the method of radiographic measurement and different x-ray projections, an average of up to 20.3 degrees higher angles were determined as compared with the ultrasound method. The average deviation in angles measured within and between the 2 examiners was lower for the ultrasound method than for the radiographic methods, corresponding to a higher degree of intra- and interobserver reliability. Conclusion: The ultrasound method for measuring palmar angulation in metacarpal neck fractures is simple, and appears to be more precise in comparison to radiographic methods. An exactly lateral projection of the fractured metacarpal bone can be imaged without superposition and exposure to radiation. The question arises whether previous studies that suggested normal hand function with palmar angulation up to 70 might have been based on too high angle-readings due to the use of radiographic methods.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 19 条
[1]   The biomechanical effects of angulated boxer's fractures [J].
Ali, A ;
Hamman, J ;
Mass, DP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (04) :835-844
[2]  
AMADIO PC, 1991, FLYNNS HAND SURG FRA
[3]   Metacarpal fracture angulation decreases flexor mechanical efficiency in human hands [J].
Birndorf, MS ;
Daley, R ;
Greenwald, DP .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (04) :1079-1083
[4]   Are lateral X-rays useful in the treatment of fractures of the fourth and fifth metacarpals? [J].
Braakman, M .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (01) :1-3
[5]   Functional taping of fractures of the 5th metacarpal results in a quicker recovery [J].
Braakman, M ;
Oderwald, EE ;
Haentjens, MHHJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (01) :5-9
[6]   The treatment of fractures of the ring and little metacarpal necks - A prospective randomized study of three different types of treatment [J].
Hansen, PB ;
Hansen, TB .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (02) :245-247
[7]   The use of a moulded metacarpal brace versus neighbour strapping for fractures of the little finger metacarpal neck [J].
Harding, IJ ;
Parry, D ;
Barrington, RL .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (03) :261-263
[8]  
Hunter J M, 1970, J Bone Joint Surg Am, V52, P1159
[9]   FUNCTIONAL TREATMENT OF METACARPAL FRACTURES - 100 RANDOMIZED CASES WITH OR WITHOUT FIXATION [J].
KONRADSEN, L ;
NIELSEN, PT ;
ALBRECHTBESTE, E .
ACTA ORTHOPAEDICA SCANDINAVICA, 1990, 61 (06) :531-534
[10]  
Kuokkanen HOM, 1999, SCAND J PLAST RECONS, V33, P315