Laparoscopic sacral colpopexy and a new approach to mesh fixation: a randomized clinical trial

被引:14
作者
Morciano, Andrea [1 ]
Marzo, Giuseppe [1 ]
Caliandro, Dario [1 ]
Campagna, Giuseppe [2 ]
Panico, Giovanni [2 ]
Alcaino, Simona [1 ]
Bisanti, Tatiana [1 ]
Ercoli, Alfredo [3 ]
Romualdi, Daniela [1 ,2 ]
Scambia, Giovanni [2 ]
机构
[1] Pia Fdn Card G Panico, Dept Obstet & Gynaecol, Lecce, Italy
[2] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli, Dept Obstet & Gynaecol, Rome, Italy
[3] Univ Piemonte Orientale Amedeo Avogadro, Dept Obstet & Gynaecol, Novara, Italy
关键词
Sacral colpopexy; Laparoscopy; Continuous suture; Running suture; Mesh fixation; Pelvic organ prolapse; PELVIC ORGAN PROLAPSE; SACROCOLPOPEXY; SURGERY; HYSTERECTOMY; OUTCOMES; COHORT;
D O I
10.1007/s00404-018-4916-0
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
PurposeLaparoscopic sacral colpopexy (LSC) plus supracervical hysterectomy (LSH) for pelvic organ prolapse (POP) is a high-complexity surgical procedure. The aim of the present study was to evaluate a new approach to vaginal-mesh fixation during LSC with continuous locked suture.MethodsThis is a prospective randomized double-blinded clinical trial enrolling 90 patients with severe POP from January 2016 to April 2017. Patients underwent LSH plus a two-meshes LSC and were randomized, regarding mesh fixation, in Group 1 (extracorporeal interrupted 3-0 delayed absorbable sutures) and Group 2 (running locked 3-0 delayed absorbable suture). Our primary endpoints were the operative times and the secondary endpoints the incidence of intra- or post-operative complications.ResultsA total of 42 patients for group completed the study. Baseline characteristics were similar between the groups. Overall mesh fixation time (24 vs. 39min; p<0.01), and operative time (121 vs. 138min; p<0.05) resulted significantly lower in Group 2. No differences were found in terms of anatomic failure, vaginal mesh erosion or intra- or post-operative complications.ConclusionsLaparoscopic continuous locked 3-0 absorbable suture for anterior and posterior mesh fixation during LSC guaranteed a faster and effective alternative to multiple interrupted sutures. The significant operative time reduction linked to this technique should be considered even more helpful when performing a highly complex surgery such as LSC.
引用
收藏
页码:939 / 944
页数:6
相关论文
共 50 条
[21]   Laparoscopic mesh explantation and drainage of sacral abscess remote from transvaginal excision of exposed sacral colpopexy mesh [J].
Roth, Ted M. ;
Reight, Ian .
INTERNATIONAL UROGYNECOLOGY JOURNAL, 2012, 23 (07) :953-955
[22]   Laparoscopic sacral colpopexy versus total vaginal mesh for vault prolapse; comparison of cohorts [J].
Withagen, Mariella I. J. ;
Vierhout, Mark E. ;
Milani, Alfredo L. ;
Mannaerts, Guido H. H. ;
Kluivers, Kirsten B. ;
van der Weiden, Robin M. F. .
GYNECOLOGICAL SURGERY, 2013, 10 (02) :143-150
[23]   Laparoscopic Sacral Mesh Fixation for Ventral Rectopexy: Clinical Implications From a Cadaver Study [J].
Argeny, Stanislaus ;
Zaussinger, Maximillian ;
Maurer-Gesek, Barbara ;
Weninger, Wolfgang J. ;
Maier, Andrea G. ;
Reissig, Lukas F. ;
Umek, Wolfgang ;
Veit-Rubin, Nikolaus ;
Jones, Oliver M. ;
Stift, Anton ;
Riss, Stefan .
DISEASES OF THE COLON & RECTUM, 2022, 65 (05) :750-757
[24]   Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation [J].
Guido Beldi ;
Markus Wagner ;
Lukas E. Bruegger ;
Anita Kurmann ;
Daniel Candinas .
Surgical Endoscopy, 2011, 25 :749-755
[25]   Mesh shrinkage and pain in laparoscopic ventral hernia repair: a randomized clinical trial comparing suture versus tack mesh fixation [J].
Beldi, Guido ;
Wagner, Markus ;
Bruegger, Lukas E. ;
Kurmann, Anita ;
Candinas, Daniel .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (03) :749-755
[26]   Mesh fixation in TAPP laparoscopic hernia repair: introduction of a new method in a prospective randomized trial [J].
Kleidari, Behrooz ;
Mahmoudieh, Mohsen ;
Yaribakht, Mohammad ;
Homaei, Zhila .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2014, 28 (02) :531-536
[27]   Randomized clinical trial of mesh fixation with "double crown" versus "sutures and tackers" in laparoscopic ventral hernia repair [J].
Muysoms, F. ;
Vander Mijnsbrugge, G. ;
Pletinckx, P. ;
Boldo, E. ;
Jacobs, I. ;
Michiels, M. ;
Ceulemans, R. .
HERNIA, 2013, 17 (05) :603-612
[28]   Randomized clinical trial of mesh fixation with “double crown” versus “sutures and tackers” in laparoscopic ventral hernia repair [J].
F. Muysoms ;
G. Vander Mijnsbrugge ;
P. Pletinckx ;
E. Boldo ;
I. Jacobs ;
M. Michiels ;
R. Ceulemans .
Hernia, 2013, 17 :603-612
[29]   Randomized clinical trial of fibrin glue versus tacked fixation in laparoscopic groin hernia repair [J].
Tolver, Mette A. ;
Rosenberg, Jacob ;
Juul, Poul ;
Bisgaard, Thue .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (08) :2727-2733
[30]   Penetrating fixation device versus fibrin sealant for mesh fixation in laparoscopic repair of ventral hernia: a randomized controlled trial [J].
Bhattacharjee, Hemanga Kumar ;
Anand, Vishal ;
Mithun, N. K. ;
Mishra, Ashwani Kumar ;
Baksi, Aditya ;
Joshi, Mohit ;
Parshad, Rajinder .
HERNIA, 2025, 29 (01)