Comparison of absorption refrigeration cycles for efficient air-cooled solar cooling

被引:32
作者
Xu, Z. Y. [1 ]
Wang, R. Z. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar cooling; Air cooled; Absorption chiller; Steady-state simulation; WASTE HEAT; SYSTEM; PERFORMANCE; ENHANCEMENT; COLLECTORS; PROTOTYPE; OPTIONS; DRIVEN; GAS;
D O I
10.1016/j.solener.2018.04.004
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Absorption chiller is a widely used technology owing to its capability to utilize low grade thermal energy including solar thermal energy and waste heat. Yet, most solar absorption cooling systems need cooling tower to dissipate heat rejection into ambient. The use of cooling tower increases both the initial investment and water consumption, which can be improved by air-cooled solar absorption cooling system. In this paper, to give the best absorption cycle options under different conditions, five absorption refrigeration cycles suitable for air-cooled solar cooling including three double lift absorption cycles and two semi-GAX (Generator-Absorber heat eXchange) absorption cycles were compared. Steady-state simulation is carried out. Efficiencies of these cycles were calculated with LiBr-water and water-ammonia working pairs in the scenario of air-cooled solar cooling. Heat source temperatures of 75-100 degrees C from non-concentrating solar collector and air temperatures of 20-40 degrees C were considered. Both air-conditioning condition with evaporation temperature of 5 degrees C and sub-zero condition with -10 degrees C were discussed. It is found that mass-coupled semi-GAX absorption cycle with ammonia-water is suitable for air-conditioning with higher heat source temperatures, mass-coupled double lift absorption cycle with water-LiBr is suitable for air-conditioning with lower heat source temperature and mass-coupled double lift absorption cycle with ammonia-water is suitable for sub-zero conditions.
引用
收藏
页码:14 / 23
页数:10
相关论文
共 29 条
[1]   Modeling of a solar powered absorption cycle for Abu Dhabi [J].
Al-Alili, A. ;
Islam, M. D. ;
Kubo, I. ;
Hwang, Y. ;
Radermacher, R. .
APPLIED ENERGY, 2012, 93 :160-167
[2]  
[Anonymous], [No title captured]
[3]   Experimental and numerical analysis of an air-cooled double-lift NH3-H2O absorption refrigeration system [J].
Aprile, Marcello ;
Toppi, Tommaso ;
Guerra, Marco ;
Motta, Mario .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 50 :57-68
[4]   Simulation and optimization of a LiBr solar absorption cooling system with evacuated tube collectors [J].
Assilzadeh, F ;
Kalogirou, SA ;
Ali, Y ;
Sopian, K .
RENEWABLE ENERGY, 2005, 30 (08) :1143-1159
[5]   Use of parabolic trough solar collectors for solar refrigeration and air-conditioning applications [J].
Cabrera, F. J. ;
Fernandez-Garcia, A. ;
Silva, R. M. P. ;
Perez-Garcia, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 20 :103-118
[6]   Experimental and analytical study on an air-cooled single effect LiBr-H2O absorption chiller driven by evacuated glass tube solar collector for cooling application in residential buildings [J].
Chen, J. F. ;
Dai, Y. J. ;
Wang, R. Z. .
SOLAR ENERGY, 2017, 151 :110-118
[7]   Experimental studies on an air-cooled two-stage NH3-H2O solar absorption air-conditioning prototype [J].
Du, S. ;
Wang, R. Z. ;
Lin, P. ;
Xu, Z. Z. ;
Pan, Q. W. ;
Xu, S. C. .
ENERGY, 2012, 45 (01) :581-587
[8]  
Herold K.E., 1996, Absorption Chillers and Heat Pumps
[9]  
Inoue N., 2003, T JPN SOC REFRIG AIR, V20, P297
[10]   Review of advanced absorption cycles: performance improvement and temperature lift enhancement [J].
Kang, YT ;
Kunugi, Y ;
Kashiwagi, T .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (05) :388-401