Monitoring Ion Beam Therapy With a Compton Camera: Simulation Studies of the Clinical Feasibility

被引:31
作者
Fontana, M. [1 ]
Ley, J. -L. [1 ]
Dauvergne, D. [2 ]
Freud, N. [3 ]
Krimmer, J. [1 ]
Letang, J. M. [3 ]
Maxim, V. [3 ]
Richard, M. -H. [1 ]
Rinaldi, I. [1 ]
Testa, E. [1 ]
机构
[1] Univ Claude Bernard Lyon 1, CNRS IN2P3, Inst Phys Nucl Lyon, Univ Lyon, F-69622 Villeurbanne, France
[2] Univ Grenoble Alpes, CNRS, LPSC IN2P3, Grenoble INP, F-38000 Grenoble, France
[3] Univ Claude Bernard Lyon 1, CREATIS UMR 5220 U1206, Univ Lyon, CNRS,Inserm,Ctr Leon Berard,INSA Lyon,UJM St Etie, F-69373 Lyon, France
关键词
Clinical applicability; Compton camera; ion therapy; prompt gamma (PG); IMAGE-RECONSTRUCTION; PROTON THERAPY; SLIT CAMERA; OPTIMIZATION; IRRADIATION; RESOLUTION; EMISSION; DESIGN;
D O I
10.1109/TRPMS.2019.2933985
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As more and more particle therapy centers are being built world-wide, there is increasing need in treatment monitoring methods, ideally in real time. This article investigates the clinical applicability of a Compton camera design by means of Monte Carlo simulations. The Compton camera performance has been studied with the simulation of point-like source and beam irradiation of a polymethyl methacrylate (PMMA) phantom. The system absolute photon detection efficiency, measured via source irradiation, varies in the range [1, 4] x 10(-4) with energy variations in the prompt gamma (PG) energy range and source position shifts with respect to the center of the camera. With proton and carbon beams impinging on a PMMA cylindrical phantom, the number of detected PG coincidences related to various beam time structure has been studied. Finally, the accuracy of the camera in identifying the dose profile fall-off position has been estimated and two different event reconstruction methods have been compared for this purpose; one based on analytical calculation with a line-cone technique, the second relying on an iterative maximum likelihood expectation maximization algorithm. Both methods showed the possibility to reconstruct the beam depth-dose profile and to retrieve the dose fall-off with millimeter precision on a spot basis.
引用
收藏
页码:218 / 232
页数:15
相关论文
共 59 条
[1]   Development of a Compton camera for prompt-gamma medical imaging [J].
Aldawood, S. ;
Thirolf, P. G. ;
Miani, A. ;
Boehmer, M. ;
Dedes, G. ;
Gernhauser, R. ;
Lang, C. ;
Liprandi, S. ;
Maier, L. ;
Marinsek, T. ;
Mayerhofer, M. ;
Schaart, D. R. ;
Lozano, I. Valencia ;
Parodi, K. .
RADIATION PHYSICS AND CHEMISTRY, 2017, 140 :190-197
[2]   Resolution recovery for Compton camera using origin ensemble algorithm [J].
Andreyev, A. ;
Celler, A. ;
Ozsahin, I. ;
Sitek, A. .
MEDICAL PHYSICS, 2016, 43 (08) :4866-4876
[3]   Fast image reconstruction for Compton camera using stochastic origin ensemble approach [J].
Andreyev, Andriy ;
Sitek, Arkadiusz ;
Celler, Anna .
MEDICAL PHYSICS, 2011, 38 (01) :429-438
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], [No title captured]
[6]  
[Anonymous], [No title captured]
[7]  
[Anonymous], [No title captured]
[8]  
[Anonymous], [No title captured]
[9]   On the ionization curves of radium. [J].
Bragg, W. H. ;
Kleeman, R. .
PHILOSOPHICAL MAGAZINE, 1904, 8 (43-48) :726-738
[10]   Feasibility Studies of a New Event Selection Method to Improve Spatial Resolution of Compton Imaging for Medical Applications [J].
Draeger E. ;
Peterson S. ;
Mackin D. ;
Chen H. ;
Beddar S. ;
Polf J.C. .
IEEE Trans. Radiat. Plasma Med. Sci., 4 (358-367) :358-367