Comparison of Two Different Methods of Fine Needle Aspiration Biopsy and Histopathology for Thyroid Nodules

被引:5
|
作者
Karakas, Hakki M. [1 ]
Bicer, Gulsah [1 ]
Findik, Ozge [1 ]
Kahraman, Ahmet Nedim [1 ]
机构
[1] Univ Hlth Sci, Istanbul Fatih Sultan Mehmet Training & Res Hosp, Radiol, Istanbul, Turkey
关键词
thyroid nodules; usg-guided biopsy; cytopathology; MANAGEMENT; CAPILLARY; CYTOLOGY; SYSTEM;
D O I
10.7759/cureus.6740
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Two different methods for fine needle aspiration biopsy (FNAB) of thyroid nodules (multi-pass conventional smear, MPCS; single-pass liquid-based cytology, SPLBC) were evaluated regarding the magnitude of nondiagnostic/unsatisfactory sampling ratio, and basic demographic and ultrasonographic (USG) factors to predict such outcome. Methods: One thousand FNAB patients were retrospectively assessed. Of them, 517 nodules were evaluated with the conventional smear method, and the rest were evaluated with liquid-based cytology method using the Bethesda System for Reporting Thyroid Cytopathology. FNAB technique had certain procedural differences for both pathological methods. For conventional smear, a modified "needle-only" technique with three independent passes was performed, whereas a single pass was used for liquid-based cytology. The reduction of nondiagnostic/unsatisfactory results constituted the basis of this study. Pathological results, therefore, were subgrouped under "nondiagnostic/unsatisfactory" (Category I), "benign" (Category II), and "atypia/neoplasia/malignancy" (Category III-VI). Results: Both FNAB groups were not statistically different or only slightly different regarding size (P = 0.196), echogenicity (P = 0.014), and the presence of echogenic foci (P = 0.11), therefore considered to have equal USG properties. In MPCS method, the nondiagnostic/unsatisfactory rate (i.e., Category I) was 24%. Other cytological results were as follows: Category 11(67.1%), Category III-VI (8.8%). In SPLBC method, the nondiagnostic/unsatisfactory rate (i.e., Category I) was 14.5%. Other cytological results were as follows: Category 11 (77.6%), Category III-VI (7.8%). A significant difference was found between two sampling methods regarding pathological results (Independent samples t-test, P < 0.0001). The demographic and USG factors, considered in this study, did not offer a successful prediction of nondiagnostic/unsatisfactory outcomes. Conclusion: SPLBC has significantly lower (14.5% vs 24%) nondiagnostic rate than MPCS, and higher 77.6% vs 67.1%) Category 11 rate than MPCS. This may point to the possibility that MPCS method undercategorizes many benign (i.e., Category II) nodules under nondiagnostic/unsatisfactory category. The success of the former is due to the elimination of confounding material during the process. Single pass, also, increases patient comfort and compliance, and has additional advantages for the interventionalist, as it obviates the need to smear aspirates. This dramatically decreases the actual duration of the biopsy procedure and is free of interventionalist expertise for smearing.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Comparison of core-needle biopsy and repeat fine-needle aspiration for thyroid nodules with inconclusive initial cytology
    Jung, Seon Min
    Koo, Hye Ryoung
    Jang, Ki Seok
    Chung, Min Sung
    Song, Chang Myeon
    Ji, Yong Bae
    Park, Jeong Seon
    Tae, Kyung
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (08) : 3019 - 3025
  • [42] Core Needle Biopsy in Suspicious Malignant Thyroid Nodules with Repeated Nondiagnostic Fine Needle Aspiration
    Farrokh Heidari
    Firouzeh Heidari
    Mohammad Sadeq Najafi
    Reza Ansari
    Kayvan Aghazadeh
    Saeed Sohrabpour
    Ebrahim Karimi
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2022, 74 : 2071 - 2075
  • [43] Core needle biopsy in the management of thyroid nodules with an indeterminate fine-needle aspiration report
    Yim, Younghee
    Baek, Jung Hwan
    GLAND SURGERY, 2019, 8 : S77 - S85
  • [44] Comparison of fine needle aspiration and non-aspiration cytology for diagnosis of thyroid nodules: A prospective, randomized, and controlled trial
    Wang, Dan
    Fu, Hui-Jun
    Xu, Hui-Xiong
    Guo, Le-Hang
    Li, Xiao-Long
    He, Ya-Ping
    Bo, Xiao-Wan
    Zhao, Chong-Ke
    Sun, Li-Ping
    Lu, Feng
    Zhang, Kun
    Wei, Qing
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 66 (01) : 67 - 81
  • [45] Fine-needle aspiration biopsy versus ultrasoundguided fine-needle aspiration biopsy: Costeffectiveness as a frontline diagnostic modality for solitary thyroid nodules
    Khalid, Ayesha N.
    Quraishi, Sadeq A.
    Hollenbeak, Christopher S.
    Stack, Brendan C., Jr.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2008, 30 (08): : 1035 - 1039
  • [46] Diagnostic accuracy of fine needle aspiration cytology of thyroid nodules
    Erkinuresin, Taskin
    Demirci, Hakan
    DIAGNOSIS, 2020, 7 (01) : 61 - 66
  • [47] Pediatric thyroid nodules:: Management in the era of fine needle aspiration
    Lugo-Vicente, H
    Ortiz, VN
    Irizarry, H
    Camps, JI
    Pagán, V
    JOURNAL OF PEDIATRIC SURGERY, 1998, 33 (08) : 1302 - 1305
  • [48] Comparison of Fine Needle Aspiration and Fine Needle Nonaspiration Cytology of Thyroid Nodules: A Meta-Analysis
    Song, Hongming
    Wei, Chuankui
    Li, Dengfeng
    Hua, Kaiyao
    Song, Jialu
    Maskey, Niraj
    Fang, Lin
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [49] Diagnostic utility of fine needle aspiration cytology in pediatric thyroid nodules based on Bethesda Classification
    Jiang, Wen
    Phillips, Susan A.
    Newbury, Robert O.
    Naheedy, John H.
    Newfield, Ron S.
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2021, 34 (04) : 449 - 455
  • [50] Effect of nodule size on the reliability of fine-needle aspiration biopsy in thyroid nodules
    Ucar, Ali Erkan
    Sarikaya, Seyit Muhsin
    Parlak, Omer
    Yalcin, Abdussamed
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2014, 44 (06) : 1002 - 1009