A parabolic-trough collector for cleaner industrial process heat

被引:88
作者
Fernandez-Garcia, Aranzazu [1 ]
Rojas, Esther [1 ]
Perez, Manuel [2 ]
Silva, Ricardo [2 ]
Hernandez-Escobedo, Quetzalcoatl [4 ]
Manzano-Agugliaro, Francisco [3 ]
机构
[1] CIEMAT Plataforma Solar Almeria, E-04200 Tabernas, Almeria, Spain
[2] Univ Almeria, UAL CIEMAT Joint Ctr, CIESOL Res Ctr Solar Energy, E-04120 Almeria, Spain
[3] Univ Almeria, Dept Engn, CEIA3, E-04120 Almeria, Spain
[4] Univ Veracruzana, Fac Ingn, Coatzacoalcos 96536, Veracruz, Mexico
关键词
Cleaner industrial process heat; Parabolic-trough solar collector; Flat cover; Thermal performance; CFD analysis; OPTICAL DURABILITY; SOLAR; ECOLOGY; DESALINATION; SUSTAINABILITY; PERFORMANCE; SYSTEM;
D O I
10.1016/j.jclepro.2014.11.018
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Despite its huge potential for increasing sustainability, the use of solar energy in industry is still scarce. Many industrial thermal demands range from 120 to 250 degrees C, which are difficult to supply using solar energy because of the lack of specific solar thermal conversion devices. Parabolic-trough collectors (PTCs) suitable for these applications should be small due to space constraints. This study addressed the specific design of a small-sized industrial PTC with a flat transparent cover in the aperture plane. The cover is critical to the success of this technology in industrial environments, because it ensures protection of the rest of the collector components, which may have very poor durability. The cover also increases rigidity and makes cleaning easier. Three different PTCs with the same basic geometry were analysed by numerical simulation. Two of them had glass receiver tube covers, one with an additional flat cover in the aperture plane and the other one without it. The third one had an uncovered receiver but a flat cover in the aperture plane. Simulations showed that the collector design with a flat glass aperture cover only has the highest thermal losses. The design with both flat glass aperture and tube covers has lower thermal losses than the one with a glass tube cover only. However, optical-geometric efficiency is inferior and, as a result, overall efficiency is slightly lower. In addition, thermal insulation on the reflector back is not recommended. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:272 / 285
页数:14
相关论文
共 74 条
[1]  
[Anonymous], 2013, Key World Energy Statistics 2013
[2]  
[Anonymous], 2007, US GUID MOD GUID
[3]  
[Anonymous], 2012, E90382 ASTM INT
[4]  
[Anonymous], 2011, SUN WIND ENERGY, V9, P70
[5]  
[Anonymous], ECOHEATCOOL EUROPEAN
[6]  
[Anonymous], 2006, US GUID
[7]   EMISSIVITY OF CLEAR SKIES [J].
BERDAHL, P ;
MARTIN, M .
SOLAR ENERGY, 1984, 32 (05) :663-664
[8]   Use of parabolic trough solar collectors for solar refrigeration and air-conditioning applications [J].
Cabrera, F. J. ;
Fernandez-Garcia, A. ;
Silva, R. M. P. ;
Perez-Garcia, M. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2013, 20 :103-118
[9]  
Canada S., 2005, DOE SOL EN TECH C DE, P7
[10]   EXPLICIT EQUATION FOR FRICTION FACTOR IN PIPE [J].
CHEN, NH .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1979, 18 (03) :296-297