CCD mosaic technique for large-field digital mammography

被引:24
作者
Jalink, A
McAdoo, J
Halama, G
Liu, H
机构
[1] SCI APPLICAT INT CORP,HAMPTON,VA 23669
[2] UNIV VIRGINIA,CHARLOTTESVILLE,VA 22903
关键词
D O I
10.1109/42.500135
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a novel technique for large-field digital mammography. The instrument uses a mosaic of electronic digital imaging [charge coupled device (CCD)] arrays, novel area scanning, and a radiation exposure and scatter reducing mechanism, The imaging arrays are mounted on a carrier platform in a checker-board pattern mosaic. To fill in the gaps between array-active areas the platform is repositioned three times and four X-ray exposures are made, The multiple image areas are then recombined by a digital computer to produce a composite image of the entire region, To reduce X-ray scatter and exposure, a lead aperture plate is interposed between X-ray source and patient, The aperture plate has a mosaic of square holes in alignment with the imaging array pattern and the plate is repositioned in synchronism with the carrier platform, We discuss proof-of-concept testing demonstrating technical feasibility of our approach, The instrument should be suitable for incorporation into standard mammography units, Unique features of the new technique are: large field coverage (18 x 24 cm); high spatial resolution (14-17 lp/mm); scatter rejection; and excellent contrast characteristics and lesion detectability under clinical conditions.
引用
收藏
页码:260 / 267
页数:8
相关论文
共 30 条
[11]   A TIME-DELAY INTEGRATION CHARGE-COUPLED DEVICE CAMERA FOR SLOT-SCANNED DIGITAL RADIOGRAPHY [J].
HOLDSWORTH, DW ;
GERSON, RK ;
FENSTER, A .
MEDICAL PHYSICS, 1990, 17 (05) :876-886
[12]   COHERENT SCATTER IN DIAGNOSTIC-RADIOLOGY [J].
JOHNS, PC ;
YAFFE, MJ .
MEDICAL PHYSICS, 1983, 10 (01) :40-50
[13]   IMAGING OF RADIONUCLIDE EMISSIONS WITH A LOW-NOISE CHARGE-COUPLED-DEVICE [J].
KARELLAS, A ;
HONG, L ;
REINHARDT, C ;
HARRIS, LJ ;
BRILL, AB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :979-982
[14]   CHARGE-COUPLED DEVICE DETECTOR - PERFORMANCE CONSIDERATIONS AND POTENTIAL FOR SMALL-FIELD MAMMOGRAPHIC IMAGING APPLICATIONS [J].
KARELLAS, A ;
HARRIS, LJ ;
LIU, H ;
DAVIS, MA ;
DORSI, CJ .
MEDICAL PHYSICS, 1992, 19 (04) :1015-1023
[15]  
KARELLAS A, 1992, P SOC PHOTO-OPT INS, V1655, P85, DOI 10.1117/12.60329
[16]   NEW MAMMOGRAPHY SCREE FILM COMBINATIONS - IMAGING CHARACTERISTICS AND RADIATION-DOSE [J].
KIMMESMITH, C ;
BASSETT, LW ;
GOLD, RH ;
ZHEUTLIN, J ;
GORNBEIN, JA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (04) :713-719
[17]  
LIU H, 1994, P SOC PHOTO-OPT INS, V2132, P301, DOI 10.1117/12.176573
[18]   METHODS TO CALCULATE THE LENS EFFICIENCY IN OPTICALLY COUPLED CCD X-RAY-IMAGING SYSTEMS [J].
LIU, H ;
KARELLAS, A ;
HARRIS, LJ ;
DORSI, CJ .
MEDICAL PHYSICS, 1994, 21 (07) :1193-1195
[19]  
LIU H, 1993, P SOC PHOTO-OPT INS, V1894, P136, DOI 10.1117/12.154943
[20]   LESION DETECTABILITY CONSIDERATIONS FOR AN OPTICALLY-COUPLED CCD X-RAY-IMAGING SYSTEM [J].
LIU, H ;
KARELLAS, A ;
MOORE, SC ;
HARRIS, LJ ;
DORSI, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1506-1509