Dose reduction in pediatric CT: A rational approach

被引:190
作者
Boone, JM [1 ]
Geraghty, EM [1 ]
Seibert, JA [1 ]
Wootton-Gorges, SL [1 ]
机构
[1] Univ Calif Davis, Med Ctr, Dept Radiol, Sacramento, CA 95817 USA
关键词
abdomen; CT; computed tomography (CT); in infants and children; radiation exposure; head; radiations; exposure to patients and personnel;
D O I
10.1148/radiol.2282020471
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine size-dependent technique factors for pediatric computed tomography (CT) by using physically measured objective data. MATERIALS AND METHODS: Six phantom cylinders (10-32 cm in diameter) were scanned with a clinical multi-detector row CT scanner. CT noise was statistically characterized for CT technique factors from 80 to 140 kVp and from 10 to 300 mAs. Dose measurements were performed with each phantom. Dilute iodine and tissue contrast were determined with computer calculations validated with measured data. The dose, noise, and contrast data were computer fit, and pediatric CT technique factors (milliampere seconds) necessary to maintain the contrast-to-noise ratio (CNR) were computed. RESULTS: As compared with that in a reference cylindric adult abdomen of 28 cm in diameter, CNR was maintained at a constant level in pediatric patients of 25, 2 and 15 cm in diameter, respectively, when milliampere second values of 0.557, 0.196, and 0.054 of the adult milliampere second values were used. The corresponding doses were reduced to 0.642, 0.287, and 0.090 of the 28-cm-diameter adult dose, respectively. CT techniques for examination of pediatric heads measuring 15 and 13 cm, respectively, can involve the use of milliampere second values of 0.572 and 0.366 of those used for examination of a standard 17-cm-diameter adult head. CONCLUSION: CT technique charts for pediatric abdominal and head examinations were produced on the basis of physically measured data; use of these tables will enable pediatric radiation dose to be reduced while CNR is preserved. (C) RSNA 2003.
引用
收藏
页码:352 / 360
页数:9
相关论文
共 31 条
  • [1] Energy imparted and effective doses in computed tomography
    Atherton, JV
    Huda, W
    [J]. MEDICAL PHYSICS, 1996, 23 (05) : 735 - 741
  • [2] Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment
    Boone, JM
    [J]. RADIOLOGY, 1999, 213 (01) : 23 - 37
  • [3] Accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV
    Boone, JM
    Seibert, JA
    [J]. MEDICAL PHYSICS, 1997, 24 (11) : 1661 - 1670
  • [4] Comparison of x-ray cross sections for diagnostic and therapeutic medical physics
    Boone, JM
    Chavez, AE
    [J]. MEDICAL PHYSICS, 1996, 23 (12) : 1997 - 2005
  • [5] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [6] Thoracic CT technique in children
    Brody, AS
    [J]. JOURNAL OF THORACIC IMAGING, 2001, 16 (04) : 259 - 268
  • [7] BUSHBERG J, 2002, ESSENTIAL PHYSICS ME
  • [8] Radiation dose reduction in paediatric cranial CT
    Chan, CY
    Wong, YC
    Chau, LF
    Yu, SK
    Lau, PC
    [J]. PEDIATRIC RADIOLOGY, 1999, 29 (10) : 770 - 775
  • [9] Cohnen M, 2000, AM J NEURORADIOL, V21, P1654
  • [10] Coren ME, 1998, PEDIATR PULM, V26, P389, DOI 10.1002/(SICI)1099-0496(199812)26:6<389::AID-PPUL3>3.0.CO