Critical quality prediction for saturated flow boiling of CO2 in horizontal small diameter tubes

被引:55
作者
Yun, R [1 ]
Kim, YC [1 ]
机构
[1] Korea Univ, Dept Engn Mech, Sungbuk Ku, Seoul 136701, South Korea
关键词
dryout; CO2; evaporation; CHF model;
D O I
10.1016/S0017-9310(03)00036-X
中图分类号
O414.1 [热力学];
学科分类号
摘要
The dryout for flow boiling carbon dioxide (CO2) in horizontal small diameter tubes is investigated through experiment and theoretical modeling. Tests are conducted in conditions where the saturation temperature is 0, 5, and 10 degreesC, heat flux is 7.2-48.1 kW/m(2) and mass flux is 500-3000 kg/m(2) s. The dryout phenomena of CO2 are similar with those of water in many respects, while the effects of mass flux on dryout show differences among them. The dryout of CO2 is predicted by a theoretical dryout model, which is developed and verified with steam-water data. Two entrainment mechanisms of interface deformation and bubble bursting are considered in the model and dryout is determined when the liquid film thickness is less than the critical liquid film thickness, the criteria film thickness of dryout. The present model well predicts the experimental critical qualities except when mass flux is relatively high, at which the deposition of liquid droplet on the liquid film and the occurrence of dryout patches become very significant. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2527 / 2535
页数:9
相关论文
共 23 条
[1]   FLUID TO FLUID MODELING OF CRITICAL HEAT-FLUX - COMPENSATED DISTORTION MODEL [J].
AHMAD, SY .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1973, 16 (03) :641-662
[2]  
BECKER KM, 1965, AE17 HEAT ENG LAB AB
[3]  
BROWN JS, 2002, ASHRAE T, V108
[4]  
CAREY VP, 1992, LIQUID VAPOR PHASE C, P439
[5]   Critical heat flux prediction for saturated flow boiling of water in vertical tubes [J].
Celata, GP ;
Mishima, K ;
Zummo, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) :4323-4331
[6]   HEAT-TRANSFER TO FALLING LIQUID-FILMS AND FILM BREAKDOWN .1. SUBCOOLED LIQUID-FILMS [J].
FUJITA, T ;
UEDA, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1978, 21 (02) :97-108
[7]   HEAT-TRANSFER TO FALLING LIQUID-FILMS AND FILM BREAKDOWN .1. SUBCOOLED LIQUID-FILMS [J].
FUJITA, T ;
UEDA, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1978, 21 (02) :97-108
[8]   The 1995 look-up table for critical heat flux in tubes [J].
Groeneveld, DC ;
Leung, LKH ;
Kirillov, PL ;
Bobkov, VP ;
Smogalev, IP ;
Vinogradov, VN ;
Huang, XC ;
Royer, E .
NUCLEAR ENGINEERING AND DESIGN, 1996, 163 (1-2) :1-23
[9]   PHENOMENOLOGICAL MODELING OF NONEQUILIBRIUM FLOWS WITH PHASE-CHANGE [J].
HEWITT, GF ;
GOVAN, AH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1990, 33 (02) :229-242
[10]  
Hihara E., 2000, P 4 IIR GUST LOR C N, P279