Programming peculiarities in two cochlear implant users with superficial siderosis of the central nervous system

被引:5
作者
Bittencourt, Aline Gomes [1 ]
Schmidt Goffi-Gomez, Maria Valeria [1 ]
Pinna, Mariana Hausen [1 ]
Bento, Ricardo Ferreira [1 ]
de Brito, Rubens [1 ]
Tsuji, Robinson Koji [1 ]
机构
[1] Univ Sao Paulo, Sch Med, Hosp Clin, Dept Otolaryngol, BR-05403000 Sao Paulo, Brazil
关键词
Superficial siderosis; Cochlear implantation; Sensorineural hearing loss; Hemosiderin; Subarachnoid hemorrhage; Magnetic resonance imaging; IMPEDANCE; PATIENT;
D O I
10.1007/s00405-011-1850-1
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
To report the audiological outcomes of cochlear implantation in two patients with severe to profound sensorineural hearing loss secondary to superficial siderosis of the CNS and discuss some programming peculiarities that were found in these cases. Retrospective review. Data concerning clinical presentation, diagnosis and audiological assessment pre- and post-implantation were collected of two patients with superficial siderosis of the CNS. Both patients showed good hearing thresholds but variable speech perception outcomes. One patient did not achieve open-set speech recognition, but the other achieved 70% speech recognition in quiet. Electrical compound action potentials could not be elicited in either patient. Map parameters showed the need for increased charge. Electrode impedances showed high longitudinal variability. The implants were fairly beneficial in restoring hearing and improving communication abilities although many reprogramming sessions have been required. The hurdle in programming was the need of frequent adjustments due to the physiologic variations in electrical discharges and neural conduction, besides the changes in the impedances. Patients diagnosed with superficial siderosis may achieve limited results in speech perception scores due to both cochlear and retrocochlear reasons. Careful counseling about the results must be given to the patients and their families before the cochlear implantation indication.
引用
收藏
页码:1555 / 1563
页数:9
相关论文
共 18 条
[1]   SUCCESSFUL COCHLEAR IMPLANTATION IN A PATIENT WITH SUPERFICIAL SIDEROSIS OF THE CENTRAL NERVOUS SYSTEM [J].
Bird, Philip A. ;
Monteath, Penny ;
Healy, Leonard .
OTOLOGY & NEUROTOLOGY, 2010, 31 (01) :177-177
[2]   Cochlear implantation in a patient with superficial siderosis of the central nervous system [J].
Dhooge, IJM ;
De Vel, E ;
Urgell, H ;
Gallégo, S ;
Vinck, B .
OTOLOGY & NEUROTOLOGY, 2002, 23 (04) :468-472
[3]   Cochlear implantation in patients with superficial leptomeningeal hemosiderosis [J].
Haferkamp, C ;
Schabet, M ;
Plinkert, PK .
HNO, 1999, 47 (07) :642-646
[4]   Successful cochlear implantation in a patient with superficial siderosis [J].
Hathaway, Bridget ;
Hirsch, Barry ;
Branstetter, Barton .
AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2006, 27 (04) :255-258
[5]   A longitudinal study of electrode impedance, the electrically evoked compound action potential, and behavioral measures in Nucleus 24 cochlear implant users [J].
Hughes, ML ;
Werff, KRV ;
Brown, CJ ;
Abbas, PJ ;
Kelsay, DMR ;
Teagle, HFB ;
Lowder, MW .
EAR AND HEARING, 2001, 22 (06) :471-486
[6]   Cochlear implantation in superficial siderosis [J].
Irving, RM ;
Graham, JM .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1996, 110 (12) :1151-1153
[7]   Superficial siderosis of the meninges and its otolaryngologic connection: A series of five patients [J].
Kale, SU ;
Donaldson, I ;
West, RJ ;
Shehu, A .
OTOLOGY & NEUROTOLOGY, 2003, 24 (01) :90-95
[8]   Cochlear implantation in superficial siderosis [J].
Kim, Chong-Sun ;
Song, Jae-Jun ;
Park, Min-Hyun ;
Kim, Young Ho ;
Koo, Ja-Won .
ACTA OTO-LARYNGOLOGICA, 2006, 126 (08) :892-896
[9]   Superficial siderosis - Associations and therapeutic implications [J].
Kumar, Neeraj .
ARCHIVES OF NEUROLOGY, 2007, 64 (04) :491-496
[10]  
Levy M, 2007, NAT CLIN PRACT NEURO, V3, P54, DOI 10.1038/ncpneuro0356