Simultaneous Quantification of 17 Cannabinoids by LC-MS-MS in Human Plasma

被引:20
|
作者
Sempio, Cristina [1 ]
Almaraz-Quinones, Nohemi [1 ]
Jackson, Matthew [1 ]
Zhao, Wanzhu [1 ]
Wang, George Sam [2 ]
Liu, Ying [3 ]
Leehey, Maureen [3 ]
Knupp, Kelly [4 ]
Klawitter, Jelena [1 ]
Christians, Uwe [1 ]
Klawitter, Jost [1 ]
机构
[1] Univ Colorado, Dept Anesthesiol, Anschutz Med Campus, Aurora, CO 80045 USA
[2] Univ Colorado, Dept Pediat, Sect Emergency Med & Med Toxicol, Childrens Hosp Colorado, Anschutz Med Campus, Aurora, CO 80045 USA
[3] Univ Colorado, Dept Neurol, Anschutz Med Campus, Aurora, CO 80045 USA
[4] Univ Colorado, Childrens Hosp Colorado, Dept Neurol & Pediat, Anschutz Med Campus, Aurora, CO 80045 USA
关键词
URINE; THC; CANNABIDIOL; METABOLITES; VALIDATION; MS/MS; ASSAY; CBD;
D O I
10.1093/jat/bkab030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, the surge in use of tetrahydrocannabinol (THC) and cannabidiol (CBD) has increased the need for sensitive and specific analytical assays to measure the said compounds in patients, to establish dose-effect relationships and to gain knowledge of their pharmacokinetics and metabolism. We developed and validated an online extraction high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method for simultaneous quantification of 17 cannabinoids and metabolites including THC and its metabolites, CBD and its metabolites and other minor cannabinoids in human plasma. CBD-glucuronide (CBD-gluc) standard was produced in-house by isolation of CBD-gluc from urine of patients using pure CBD oil. For calibration standards and quality control samples, human plasma was spiked with cannabinoids at varying concentrations within the working range of the respective compound and 200 mu L of the plasma was extracted using a simple one-step protein precipitation procedure. The extracts were analyzed using online trapping LC/LC-atmospheric pressure chemical ionization-MS-MS running in the positive multiple reaction monitoring mode. The lower limit of quantification ranged from 0.78 to 7.8 ng/mL, and the upper limits of quantification were between 100 and 2,000 ng/mL. Inter-day analytical accuracy and imprecision ranged from 90.4% to 111% and from 3.1% to 17.4%, respectively. The analysis of plasma samples collected during clinical studies showed that (3R-trans)-cannabidiol-7-oic acid (7-CBD-COOH) was the major human metabolite with 5960% (59.6-fold) of CBD followed by 7-hydroxy-CBD (177%), CBD-gluc (157%) and 6 alpha-hydroxy-CBD (39.8%); 6 beta-hydroxy-CBD was not detected in any of the samples. In the present study, we developed and validated a robust LC-MS-MS assay for the simultaneous quantification of cannabinoids and their metabolites, which has been used to measure >5,000 samples in clinical studies. Moreover, we were able to quantify CBD-gluc and showed that 7-CBD-COOH, 7-hydroxy-CBD and CBD-gluc are the major CBD metabolites in human plasma.
引用
收藏
页码:383 / 392
页数:10
相关论文
共 50 条
  • [1] LC-MS-MS assay for simultaneous quantification of fexofenadine and pseudoephedrine in human plasma
    Bharathi, Vijaya D.
    Radharani, Kanbarpa
    Jagadeesh, Banda
    Ramulu, Gajjela
    Bhushan, Indu
    Naidu, Andra
    Mullangi, Ramesh
    CHROMATOGRAPHIA, 2008, 67 (5-6) : 461 - 466
  • [2] Quantification of Quetiapine in Human Plasma by LC-MS-MS
    Kundlik, Mohan Laxman
    Kambli, Sandeep
    Shah, Viral
    Patel, Yashwant
    Gupta, Santosh
    Sharma, Ram
    Zaware, Bhaskar
    Kuchekar, Shashikant R.
    CHROMATOGRAPHIA, 2009, 70 (11-12) : 1587 - 1592
  • [3] LC-MS-MS Simultaneous Determination of Atorvastatin and Ezetimibe in Human Plasma
    El-Bagary, Ramzia I.
    Elkady, Ehab F.
    El-Sherif, Zeinab Abdelaziz
    Kadry, Ahmed M.
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (08) : 773 - 780
  • [4] Simultaneous determination of tamsulosin and dutasteride in human plasma by LC-MS-MS
    Agarwal, Sangita
    Gowda, K. Veeran
    Sarkar, Amlan Kanti
    Ghosh, Debotri
    Bhaumik, Uttam
    Chattaraj, Tapas Kumar
    Pal, Tapan Kumar
    CHROMATOGRAPHIA, 2008, 67 (11-12) : 893 - 903
  • [5] Simultaneous LC-MS-MS Determination of Lopinavir and Rifabutin in Human Plasma
    Jaiswal, Swati
    Sharma, Abhisheak
    Shukla, Mahendra
    Lal, Jawahar
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2017, 55 (06) : 617 - 624
  • [6] Simultaneous Determination of Atenolol and Chlorthalidone by LC-MS-MS in Human Plasma
    Khuroo, Arshad
    Mishra, Sanjeev
    Singh, Onkar
    Saxena, Saurabh
    Monif, Tausif
    CHROMATOGRAPHIA, 2008, 68 (9-10) : 721 - 729
  • [7] Simultaneous LC-MS-MS Analysis of Valsartan and Hydrochlorothiazide in Human Plasma
    Shah, Hiten Janardan
    Kataria, Naresh B.
    Subbaiah, Gunta
    Patel, Chhagan N.
    CHROMATOGRAPHIA, 2009, 69 (9-10) : 1055 - 1060
  • [8] The simultaneous determination of tenofovir and enntricitabine in human plasma by LC-MS-MS
    Delahunty, T.
    Bushman, L.
    Fletcher, C. V.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A100 - A100
  • [9] LC-MS-MS Simultaneous Determination of Niacin, Niacinamide and Nicotinuric Acid in Human Plasma LC-MS-MS and Its Application to a Human Pharmacokinetic Study
    Wang, Yu
    Song, Min
    Hang, Taijun
    Wen, Aidong
    Yang, Lin
    CHROMATOGRAPHIA, 2010, 72 (3-4) : 245 - 253
  • [10] Simultaneous Determination of Buprenorphine, Norbuprenorphine and Naloxone in Human Plasma by LC-MS-MS
    Ting-Yi Chiang
    Li-Heng Pao
    Cheng-Huei Hsiong
    Pei-Wei Huang
    Kai-Wei Lin
    Oliver Yoa-Pu Hu
    Chromatographia, 2011, 74 : 575 - 583