Impact of the aging of a photovoltaic module on the performance of a grid-connected system

被引:32
作者
Azizi, Amina [1 ]
Logerais, Pierre-Olivier [2 ]
Omeiri, Amar [1 ]
Amiar, Adel [3 ]
Charki, Abderafi [4 ]
Riou, Olivier [2 ]
Delaleux, Fabien [2 ]
Durastanti, Jean-Felix [2 ]
机构
[1] Univ Badji Mokhtar, Lab Electrotech Annaba, Annaba 23000, Algeria
[2] Univ Paris Est CERTES, IUT Senart Fontainebleau, 36 Rue Georges Charpak, F-77567 Lieusaint, France
[3] Soc Algerienne Prod Elect, Unite Prod TV TG Annaba, BP 3065, Quai Sud 3065, Annaba Port, Algeria
[4] Univ Angers, LARIS, 62 Ave Notre Dame du Lac, F-49000 Angers, France
关键词
Photovoltaic system; Aging; Power degradation; Passive filter; PV SYSTEM; MPPT; ALGORITHM;
D O I
10.1016/j.solener.2018.09.022
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Photovoltaic systems belong to the green energy dynamics which is an ambitious program based on energy efficiency and sustainable development. In this study, the impact of the aging of a photovoltaic module is investigated on the electrical performance of a grid-connected system. A photovoltaic conversion chain with MPPT (Maximum Power Point Tracking) control and LC (Inductor-Capacitor) filter is modeled and dimensioned according to the grid constraints. A method of hybridation detection of the MPPT coupling long-time aging evolution and short-time determination is proposed. Aging laws for the electrical and optical degradations of the photovoltaic module are introduced for the long-time evolution. Results display the lowering of the maximal power point with a rate of 1%/year and a slight augmentation of the THD over time even though it remains inferior to the IEEE standard STD 19-1992 maximum value of 5% for a usage of 20 years. Moreover, an equivalent scheme for the additional electrical resistance engendered by the aging of the photovoltaic module regarding other resistances of the photovoltaic system is given. Finally, the elevation of this resistance by 12.8% in 20 years may have non-negligible consequences on the power production of a large-scale installation.
引用
收藏
页码:445 / 454
页数:10
相关论文
共 45 条
[1]  
Abbes H., 2013, INT C REN EN SOUSS T
[2]   Fault Tolerance Enhance DC-DC Converter Lifetime Extension [J].
Alghassi, Alireza ;
Soulatiantork, Payam ;
Samie, Mohammad ;
Del Pozo, Adrian Uriondo ;
Perinpanayagam, Suresh ;
Faifer, Marco .
PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE IN THROUGH-LIFE ENGINEERING SERVICES, 2017, 59 :268-273
[3]   An enhanced P&O checking algorithm MPPT for high tracking efficiency of partially shaded PV module [J].
Alik, Rozana ;
Jusoh, Awang .
SOLAR ENERGY, 2018, 163 :570-580
[4]  
[Anonymous], 1992, RECOMMENDED PRACTICE
[5]  
[Anonymous], 2012, Int J Eng Res Appl
[6]  
[Anonymous], 2015, The ISO survey of management system standard certifications-2014
[7]  
[Anonymous], 612152016 IEC
[8]  
Ayub M., 2014, IEEE INNOVATIVE SMAR
[9]  
Barrade P, 2006, ELECT PUISSANCE METH, V1ere
[10]   Quantification of photovoltaic module degradation using model based indicators [J].
Bastidas-Rodriguez, J. D. ;
Franco, E. ;
Petrone, G. ;
Ramos-Paja, C. A. ;
Spagnuolo, G. .
MATHEMATICS AND COMPUTERS IN SIMULATION, 2017, 131 :101-113