Biomechanical assessment of the central band of the interosseous membrane using shear wave elastography: reliability and reproducibility

被引:5
|
作者
Rougereau, Gregoire [1 ,2 ]
Marty-Diloy, Thibault [1 ]
Vigan, Marie [3 ]
Vialle, Raphael [1 ,4 ]
Soubeyrand, Marc [5 ]
Langlais, Tristan [1 ,6 ]
机构
[1] Sorbonne Univ, Armand Trousseau Hosp, AP HP, Dept Pediat Orthoped Surg, F-75571 Paris, France
[2] Sorbonne Univ, Pitie Salpetriere Hosp, AP HP, Dept Adult Orthoped Surg, Paris, France
[3] Hop Univ Paris Ile de France Ouest, AP HP, Unite Rech Clin, Boulogne, France
[4] Sorbonne Univ, MAMUTH Hosp Univ, Dept Innovat Therapies Musculoskeletal Dis, Paris, France
[5] Clin St Jean lErmitage, Dept Orthoped & Traumatol, Melun, France
[6] Univ Toulouse, Childrens hosp, Dept Pediat Orthoped Surg, Toulouse, France
关键词
Central band; ultrasound; elasticity imaging techniques; elastography; feasibility study; forearm; interosseous membrane; HEALTHY-CHILDREN; FOREARM; ULTRASOUND; PATHOLOGY; LIGAMENT; ANATOMY; MUSCLES; LOAD;
D O I
10.1177/17531934221114301
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The interosseous membrane of the forearm is an essential structure for the stability of the forearm skeleton, the most important part being the central band. The purpose of this study was to determine if shear wave elastography, a non-invasive ultrasound technique, can be used to measure shear wave speed in the central band and quantify stiffness. Fifteen healthy adult subjects were included (30 forearms). The participants forearms were positioned on an articulated plate, with their hand in neutral, pronated and then supinated positions of 30 degrees, 60 degrees and 90 degrees. The shear wave speed was highest in 90 degrees pronation (4.4 m/s (SD 0.3)) and 90 degrees supination (4.4 m/s (SD 0.27)) indicating maximum stiffness in these positions. Its minimum value was in the neutral position, and either in 30 degrees pronation or supination (3.5 m/s (SD 0.3)). Intra- and interobserver agreement was excellent, regardless of probe positioning or forearm mobilization. This study presents a reliable shear wave elastography measurement protocol to describe the physiological function of the central band of the interosseous membrane in healthy adults.
引用
收藏
页码:1134 / 1141
页数:8
相关论文
共 50 条
  • [1] Shear wave elastography assessment in the prostate: an intraobserver reproducibility study
    Woo, Sungmin
    Kim, Sang Youn
    Lee, Myoung Seok
    Cho, Jeong Yeon
    Kim, Seung Hyup
    CLINICAL IMAGING, 2015, 39 (03) : 484 - 487
  • [2] Assessment of the Passive Tension of the First Dorsal Interosseous and First Lumbrical Muscles Using Shear Wave Elastography
    Watanabe, Yudai
    Iba, Kousuke
    Taniguchi, Keigo
    Aoki, Mitsuhiro
    Sonoda, Tomoko
    Yamashita, Toshihiko
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (12): : 1092.e1 - 1092.e8
  • [3] Reproducibility of 2-Dimensional Shear Wave Elastography Assessment of the Liver
    Fang, Cheng
    Konstantatou, Eleni
    Romanos, Odyssefs
    Yusuf, Gibran T.
    Quinlan, Daniel J.
    Sidhu, Paul S.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (08) : 1563 - 1569
  • [4] REPRODUCIBILITY OF NATURAL SHEAR WAVE ELASTOGRAPHY MEASUREMENTS
    Keijzer, Lana B. H.
    Strachinaru, Mihai
    Bowen, Dan J.
    Geleijnse, Marcel L.
    van der Steen, Antonius F. W.
    Bosch, Johan G.
    de Jong, Nico
    Vos, Hendrik J.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (12): : 3172 - 3185
  • [5] SHEAR WAVE ELASTOGRAPHY ASSESSMENT OF CAROTID PLAQUE STIFFNESS: IN VITRO REPRODUCIBILITY STUDY
    Ramnarine, Kumar V.
    Garrard, James W.
    Dexter, Katie
    Nduwayo, Sarah
    Panerai, Ronney B.
    Robinson, Thompson G.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (01): : 200 - 209
  • [6] RELIABILITY OF SHEAR WAVE ELASTOGRAPHY FOR THE ASSESSMENT OF PELVIC FLOOR MUSCLE STIFFNESS
    Starzec-Proserpio, M.
    Roch, M.
    Gaudreault, N.
    Daigle, F.
    Bureau, N.
    Morin, M.
    JOURNAL OF SEXUAL MEDICINE, 2023, 20
  • [7] AUTOMATIC ASSESSMENT OF SHEAR WAVE ELASTOGRAPHY QUALITY AND MEASUREMENT RELIABILITY IN THE LIVER
    Pellot-Barakat, Claire
    Lefort, Muriel
    Chami, Linda
    Labit, Ymickael
    Frouin, Frederique
    Lucidarme, Olivier
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (04): : 936 - 943
  • [8] Reproducibility of shear wave elastography measuresof the Achilles tendon
    Catherine Payne
    Peter Watt
    Mara Cercignani
    Nick Webborn
    Skeletal Radiology, 2018, 47 : 779 - 784
  • [9] Reproducibility of shear wave elastography measuresof the Achilles tendon
    Payne, Catherine
    Watt, Peter
    Cercignani, Mara
    Webborn, Nick
    SKELETAL RADIOLOGY, 2018, 47 (06) : 779 - 784
  • [10] The reproducibility of shear wave and strain elastography in epidermal cysts
    Kim, Ji Na
    Park, Hee Jin
    Kim, Myung Sub
    Won, So Yeon
    Song, Eunhee
    Kim, Minchul
    Shin, Hyunchul
    ULTRASONOGRAPHY, 2022, 41 (04) : 698 - 705