Functional imaging with FENSI: Flow-enhanced signal intensity

被引:10
作者
Sutton, Bradley P.
Ouyang, Cheng
Ching, Bryce L.
Ciobanu, Luisa
机构
[1] Univ Illinois, Dept Bioengn, Digital Comp Lab 3120, Urbana, IL 61801 USA
[2] Univ Illinois, Beckman Inst Adv Sci & Technol, Biomed Imaging Ctr, Urbana, IL 61801 USA
关键词
functional MRI; cerebral blood flow; signal enhancement; saturation; DESIRE;
D O I
10.1002/mrm.21325
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flow measurement methods for functional MRI (fMRI) are desirable as they are more closely tied to neuronal activity than the commonly used blood oxygenation techniques. In this work we introduce a flow-based functional imaging method. The method, called flow enhancement of signal intensity (FENSI), is an extension of the diffusion enhancement of signal and resolution (DESIRE) method from MR microscopy. The FENSI method offers a localized flow-weighted signal across a very thin slice (0.4 mm in this study) that provides a signal enhancement that is dependent on the velocity and direction of the flow. The FENSI method was implemented on a human 3 T system and applied to a blocked visual cognitive task. Activation maps showed good localization and the measured signal changes of around 10% were in good agreement with the predicted enhancements.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 36 条
[1]  
Buxton R.B., 2002, Introduction to functional magnetic resonance imaging: principles and techniques, DOI DOI 10.1117/1.JBO.21.3.036008
[2]   Signal enhancement by diffusion: experimental observation of the "DESIRE" effect [J].
Ciobanu, L ;
Webb, AG ;
Pennington, CH .
JOURNAL OF MAGNETIC RESONANCE, 2004, 170 (02) :252-256
[3]   Magnetic resonance imaging of biological cells [J].
Ciobanu, L ;
Webb, AG ;
Pennington, CH .
PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2003, 42 (3-4) :69-93
[4]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[5]   Localized cerebral blood flow response at submillimeter columnar resolution [J].
Duong, TQ ;
Kim, DS ;
Ugurbil, K ;
Kim, SG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (19) :10904-10909
[6]  
Golay Xavier, 2004, Top Magn Reson Imaging, V15, P10, DOI 10.1097/00002142-200402000-00003
[7]   Nonlinear responses of cerebral blood volume, blood flow and blood oxygenation signals during visual stimulation [J].
Gu, H ;
Stein, EA ;
Yang, YH .
MAGNETIC RESONANCE IMAGING, 2005, 23 (09) :921-928
[8]  
Guyton A.C., 2006, G KHAN N AVU O LU H
[9]   Arteriolar blood flow pulsatility in a patient before and after implantation of an axial flow pump [J].
Habazettl, H ;
Kukucka, M ;
Weng, YG ;
Kuebler, WM ;
Hetzer, R ;
Kuppe, H ;
Pries, AR .
ANNALS OF THORACIC SURGERY, 2006, 81 (03) :1109-1111
[10]   Fast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system [J].
Hernandez-Garcia, L ;
Lee, GR ;
Vazquez, AL ;
Noll, DC .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) :577-585