Simulation of the X-ray response of scintillator coated silicon CCD:s

被引:0
|
作者
Frojdh, C [1 ]
Nelvig, P [1 ]
Nilsson, HE [1 ]
Petersson, CS [1 ]
机构
[1] REGAM Med Syst Int AB, S-85238 Sundsvall, Sweden
来源
1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2 | 1998年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Silicon CCD:s are used for X-ray imaging in fields as dentistry and materials testing. Due to the low X-ray absorption in Silicon the CCD is generally coated with a scintillating layer. In order to evaluate the response for different combinations of scintillator material, scintillator geometry and detector we have developed a simulation program. The program calculates the signal to noise ratio and spatial resolution based on both the signal from the scintillating layer and the signal from direct detection of X-rays in the detector. Results obtained with this program indicate that the signal to noise ratio in the system is optimized by using a scintillator with high X-ray absorption and high light output while minimizing the signal from direct detection in the CCD. The spatial resolution can be increased by defining pixels in the scintillator.
引用
收藏
页码:516 / 520
页数:5
相关论文
共 50 条
  • [1] Simulation of the X-ray response of scintillator coated silicon CCDs
    Frojdh, C.
    Nilsson, H.E.
    Nelvig, P.
    Petersson, C.S.
    IEEE Transactions on Nuclear Science, 1998, 45 (3 pt 1): : 374 - 378
  • [2] Simulation of the X-ray response of scintillator coated silicon CCDs
    Frojdh, C
    Nilsson, HE
    Nelvig, P
    Petersson, CS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 374 - 378
  • [3] Scintillator to CCD coupling in X-ray microtomography
    Davis, Graham R.
    Elliott, James C.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [4] Soft X-ray response of the X-ray CCD camera directly coated with Optical Blocking Layer
    Ikeda, S.
    Kohmura, T.
    Kawai, K.
    Kaneko, K.
    Watanabe, T.
    Tsunemi, H.
    Hayashida, K.
    Anabuki, N.
    Nakajima, H.
    Ueda, S.
    Tsuru, T. G.
    Dotani, T.
    Ozaki, M.
    Matsuta, K.
    Fujinaga, T.
    Kitamoto, S.
    Murakami, H.
    Hiraga, J.
    Mori, K.
    SUZAKU 2011: EXPLORING THE X-RAY UNIVERSE: SUZAKU AND BEYOND, 2012, 1427
  • [5] Resolution and noise properties of scintillator coated X-ray detectors
    Dubaric, E
    Fröjdh, C
    Nilsson, HE
    Petersson, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (01): : 178 - 182
  • [6] Monte Carlo simulation of the imaging properties of scintillator-coated X-ray pixel detectors
    Hjelm, M
    Norlin, B
    Nilsson, HE
    Fröjdh, C
    Badel, X
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 76 - 85
  • [7] Metallized and oxidized silicon macropore arrays filled with a scintillator for CCD-based X-ray imaging detectors
    Badel, X
    Linnros, J
    Kleimann, P
    Norlin, B
    Koskiahde, E
    Valpas, K
    Nenonen, S
    Petersson, S
    Fröjdh, C
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1006 - 1010
  • [8] Metallized and oxidized silicon macropore arrays filled with a scintillator for CCD-based X-ray imaging detectors
    Badel, X
    Linnros, J
    Kleimann, P
    Norlin, B
    Koskiahde, E
    Valpas, K
    Nenonen, S
    Petersson, CS
    Fröjdh, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1001 - 1005
  • [9] A model of the X-ray response of the ACIS CCD
    Prigozhin, G
    Rasmussen, A
    Bautz, M
    Ricker, G
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 267 - 275
  • [10] COMBINATION X-RAY DETECTOR WITH SCINTILLATOR AND SILICON PHOTODIODE.
    Gliberman, A.Ya.
    Kovalev, I.I.
    Leichenko, A.I.
    Chetverikova, G.A.
    Borisova, T.A.
    Instruments and experimental techniques New York, 1987, 30 (1 pt 2): : 216 - 218