Influence of conformity on the wear of total knee replacement: An experimental study

被引:32
作者
Brockett, Claire L. [1 ]
Carbone, Silvia [1 ]
Fisher, John [1 ]
Jennings, Louise M. [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国生物技术与生命科学研究理事会; “创新英国”项目; 英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Total knee replacement; polyethylene; wear; conformity; MOLECULAR-WEIGHT POLYETHYLENE; CROSS-LINKED POLYETHYLENE; TOTAL JOINT REPLACEMENTS; FIXED-BEARING; IN-VITRO; CONTACT PRESSURE; MOBILE-BEARING; CLINICAL-OUTCOMES; INSERT CONFORMITY; BACKSIDE WEAR;
D O I
10.1177/0954411917746433
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wear of total knee replacement continues to be a significant factor influencing the clinical longevity of implants. Historically, failure due to delamination and fatigue directed design towards more conforming inserts to reduce contact stress. As new generations of more oxidatively stable polyethylene have been developed, more flexibility in bearing design has been introduced. The aim of this study was to investigate the effect of insert conformity on the wear performance of a fixed bearing total knee replacement through experimental simulation. Two geometries of insert were studied under standard gait conditions. There was a significant reduction in wear with reducing implant conformity. This study has demonstrated that bearing conformity has a significant impact on the wear performance of a fixed bearing total knee replacement, providing opportunities to improve clinical performance through enhanced material and design selection.
引用
收藏
页码:127 / 134
页数:8
相关论文
共 49 条
  • [1] The effect of insert conformity and material on total knee replacement wear
    Abdelgaied, Abdellatif
    Brockett, Claire L.
    Liu, Feng
    Jennings, Louise M.
    Jin, Zhongmin
    Fisher, John
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (01) : 98 - 106
  • [2] Displacement or Force Control Knee Simulators? Variations in Kinematics and in Wear
    Affatato, Saverio
    [J]. ARTIFICIAL ORGANS, 2016, 40 (02) : 195 - 201
  • [3] Contribution of geometric design parameters to knee implant performance: Conflicting impact of conformity on kinematics and contact mechanics
    Ardestani, Marzieh M.
    Moazen, Mehran
    Jin, Zhongmin
    [J]. KNEE, 2015, 22 (03) : 217 - 224
  • [4] Survival analysis of total knee arthroplasty at a minimum 10 years' follow-up: A multicenter French nationwide study including 846 cases
    Argenson, J. -N.
    Boisgard, S.
    Parratte, S.
    Descamps, S.
    Bercovy, M.
    Bonnevialle, P.
    Briard, J. -L.
    Brilhault, J.
    Chouteau, J.
    Nizard, R.
    Saragaglia, D.
    Servien, E.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (04) : 385 - 390
  • [5] Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties
    Asano, Taiyo
    Akagi, Masao
    Clarke, Ian C.
    Masuda, Shingo
    Ishii, Tsunehiro
    Nakamura, Takashi
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 83B (02) : 615 - 622
  • [6] Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene
    Atwood, Sara A.
    Van Citters, Douglas W.
    Patten, Eli W.
    Furmanski, Jevan
    Ries, Michael D.
    Pruitt, Lisa A.
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) : 1033 - 1045
  • [7] Comparison of wear in a total knee replacement under different kinematic conditions
    Barnett, PI
    Fisher, J
    Auger, DD
    Stone, MH
    Ingham, E
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) : 1039 - 1042
  • [8] The wear of fixed and mobile bearing unicompartmental knee replacements
    Brockett, C. L.
    Jennings, L. M.
    Fisher, J.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H5) : 511 - 519
  • [9] Brockett CL, 2016, KNEE CONFORMITY WEAR
  • [10] Brockett CL, 2011, 24 ANN ISTA C BRUGS