Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view

被引:70
作者
Lofthag-Hansen, Sara [1 ,2 ]
Thilander-Klang, Anne [3 ,4 ]
Grondahl, Kerstin [2 ,5 ]
机构
[1] Publ Dent Hlth, Clin Oral & Maxillofacial Radiol, SE-40223 Gothenburg, Sweden
[2] Univ Gothenburg, Sahlgrenska Acad, Dept Oral & Maxillofacial Radiol, Gothenburg, Sweden
[3] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Radiat Phys, Gothenburg, Sweden
[4] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[5] Inst Postgrad Dent Educ, Dept Oral & Maxillofacial Radiol, Jonkoping, Sweden
关键词
Cone beam computed tomography; Dentomaxillofacial; Image quality; Diagnostic task; Dose-area product; FLAT-PANEL DETECTOR; CT; CBCT; RADIOGRAPHY; ARTIFACTS; DOSIMETRY; SCANNERS;
D O I
10.1016/j.ejrad.2010.09.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aims: To evaluate subjective image quality for two diagnostic tasks, periapical diagnosis and implant planning, for cone beam computed tomography (CBCT) using different exposure parameters and fields of view (FOVs). Materials and methods: Examinations were performed in posterior part of the jaws on a skull phantom with 3D Accuitomo (FOV 3 cm x 4 cm) and 3D Accuitomo FPD (FOVs 4 cm x 4 cm and 6 cm x 6 cm). All combinations of 60, 65, 70, 75, 80 kV and 2, 4, 6, 8, 10 mA with a rotation of 180 degrees and 360 degrees were used. Dose-area product (DAP) value was determined for each combination. The images were presented, displaying the object in axial, cross-sectional and sagittal views, without scanning data in a random order for each FOV and jaw. Seven observers assessed image quality on a six-point rating scale. Results: Intra-observer agreement was good (kappa(w) = 0.76) and inter-observer agreement moderate (kappa(w) = 0.52). Stepwise logistic regression showed kV, mA and diagnostic task to be the most important variables. Periapical diagnosis, regardless jaw, required higher exposure parameters compared to implant planning. Implant planning in the lower jaw required higher exposure parameters compared to upper jaw. Overall ranking of FOVs gave 4 cm x 4 cm, 6 cm x 6 cm followed by 3 cm x 4 cm. Conclusions: This study has shown that exposure parameters should be adjusted according to diagnostic task. For this particular CBCT brand a rotation of 180 degrees gave good subjective image quality, hence a substantial dose reduction can be achieved without loss of diagnostic information. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:483 / 488
页数:6
相关论文
共 20 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R, DOI DOI 10.1201/9780429258589
[2]  
[Anonymous], ANN ICRP
[3]   Comparison of flat-panel detector and image-intensifier detector for cone-beam CT [J].
Baba, R ;
Konno, Y ;
Ueda, K ;
Ikeda, S .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) :153-158
[4]   Large scan field, high spatial resolution flat-panel detector based volumetric CT of the whole human skull base and for maxillofacial imaging [J].
Bartling, S. H. ;
Majdani, O. ;
Gupta, R. ;
Rodt, T. ;
Dullin, C. ;
Fitzgerald, P. F. ;
Becker, H. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (06) :317-327
[5]   State-of-the-art on cone beam CT imaging for preoperative planning of implant placement [J].
Guerrero, ME ;
Jacobs, R ;
Loubele, M ;
Schutyser, F ;
Suetens, P ;
van Steenberghe, D .
CLINICAL ORAL INVESTIGATIONS, 2006, 10 (01) :1-7
[6]   ViewDEX: an efficient and easy-to-use software for observer performance studies [J].
Hakansson, Markus ;
Svensson, Sune ;
Zachrisson, Sara ;
Svalkvist, Angelica ;
Bath, Magnus ;
Mansson, Lars Gunnar .
RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) :42-51
[7]   Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography [J].
Katsumata, Akitoshi ;
Hirukawa, Akiko ;
Okumura, Shinji ;
Naitoh, Munetaka ;
Fujishita, Masami ;
Ariji, Eiichiro ;
Langlais, Robert P. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (06) :829-836
[8]   Cone-beam computed tomography of the maxillofacial region - an update [J].
Kau, Chung How ;
Bozic, Marko ;
English, Jeryl ;
Lee, Robert ;
Bussa, Harry ;
Ellis, Randy K. .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (04) :366-380
[9]  
LIANG X, 2009, EUR J RADIOL, DOI DOI 10.1018/JEJRAD2009.03.042
[10]   Limited cone-beam CT and intraoral radiography for the diagnosis of periapical pathology [J].
Lofthag-Hansen, Sara ;
Huumonen, Sisko ;
Grondahl, Kerstin ;
Grondahl, Hans-Goran .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (01) :114-119