Optimisation and application of ICP-MS and alpha-spectrometry for determination of isotopic ratios of depleted uranium and plutonium in samples collected in Kosovo

被引:105
作者
Boulyga, SF
Testa, C
Desideri, D
Becker, JS
机构
[1] Forschungszentrum Julich, Cent Dept Analyt Chem, D-52425 Julich, Germany
[2] Radiat Phys & Chem Problems Inst, Minsk 220109, BELARUS
[3] Univ Urbino, Fac Pharm, Inst Gen Chem, I-61029 Urbino, Italy
关键词
D O I
10.1039/b103178n
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of environmental contamination with natural and artificial actinide isotopes and evaluation of their source requires precise isotopic determination of actinides, above all uranium and plutonium. This can be achieved by alpha spectrometry or by inductively coupled plasma mass spectrometry (ICP-MS) after chemical separation of actinides. The performance of a sector-field ICP-MS (ICP-SFMS) coupled to a low-flow micronebulizer with a membrane desolvation unit, "Aridus'', was studied with respect to precise isotopic measurements of uranium and plutonium at the ultratrace level. The UH+/U+ formation rate was about 3x10(-5) and a sensitivity for U-238 of up to 4x10(9) counts s(-1) ppm(-1) was achieved. The limit of quantification (LOQ, 10s) for U-236 and Pu-239 using the experimental arrangement described above was 0.6 pg l(-1) in aqueous solution and 0.13 pg g(-1) in soil, respectively. ICP-SFMS was used in comparison to alpha spectrometry to measure the U and Pu concentrations and isotopic compositions in two soil samples and in one penetrator collected in Kosovo. ICP-MS permitted the determination of U and Pu isotope ratios including the U-236 abundance and Pu-240/Pu-239 ratio at ultratrace levels in soil samples of up to 0.1 g. Depleted uranium (U-235/U-238= 0.00202 +/-0.00001) was determined in one penetrator and one soil sample. Pu concentrations of (5.5 +/-0.1) x 10(-13) g g(-1) and (4.4 +/-0.5) x 10(-13) g g(-1) (Pu-240/Pu-239=0.35 +/-0.10 and 0.27 +/-0.07, respectively) were found in both soil samples from Kosovo. Besides plutonium, U-236 (3.1x10(-5) g g(-1)) and Am-241 (1.7x10(-12) g g(-1)) were also detected in the penetrator sample, which indicates the previous existence of neutron-related processes and points to a possible presence of spent reactor uranium in munitions. However, the most probable plutonium contamination sources in analyzed soil samples from Kosovo are mixed fallout including spent reactor fuel due to the Chernobyl nuclear power plant accident in 1986 and plutonium due to nuclear weapon tests. Additional plutonium contamination could not be determined in the Kosovo soil sample containing depleted uranium with a detection limit of about 10(-13) g g(-1).
引用
收藏
页码:1283 / 1289
页数:7
相关论文
共 48 条
[1]   DETERMINATION OF URANIUM AND THORIUM CONCENTRATIONS IN SOILS - COMPARISON OF ISOTOPE-DILUTION SECONDARY ION MASS-SPECTROMETRY AND ISOTOPE-DILUTION THERMAL IONIZATION MASS-SPECTROMETRY [J].
ADRIAENS, AG ;
FASSETT, JD ;
KELLY, WR ;
SIMONS, DS ;
ADAMS, FC .
ANALYTICAL CHEMISTRY, 1992, 64 (23) :2945-2950
[2]   The use of secondary ion mass spectrometry in radiotoxicology [J].
Amaral, A ;
Cossonnet, C ;
Galle, P .
RADIATION PROTECTION DOSIMETRY, 1998, 79 (1-4) :137-140
[3]   Perspectives of uranium and plutonium analysis in urine samples by secondary ion mass spectrometry [J].
Amaral, A ;
Galle, P ;
Cossonnet, C ;
Franck, D ;
Pihet, P ;
Carrier, M ;
Stephan, O .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 226 (1-2) :41-45
[4]  
[Anonymous], QUANTIFYING UNCERTAI
[5]  
[Anonymous], ENCY ANAL CHEM
[6]  
[Anonymous], 1997, CHEM ANAL SERIES MON
[7]   Oxide ion formation of long-lived radionuclides in double-focusing sector field inductively coupled plasma mass spectrometry and their analytical applications [J].
Becker, JS ;
Dietze, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2000, 202 (1-3) :69-79
[8]   Precise isotope ratio measurements for uranium, thorium and plutonium by quadrupole-based inductively coupled plasma mass spectrometry [J].
Becker, JS ;
Dietze, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05) :482-488
[9]   Ultratrace and isotope analysis of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using a direct injection high efficiency nebulizer [J].
Becker, JS ;
Dietze, HJ ;
McLean, JA ;
Montaser, A .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3077-3084
[10]   Application of double-focusing sector field ICP mass spectrometry with shielded torch using different nebulizers for ultratrace and precise isotope analysis of long-lived radionuclides - Invited lecture [J].
Becker, JS ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1493-1500