Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study

被引:158
|
作者
Cai, Jing [1 ]
Chang, Zheng [1 ]
Wang, Zhiheng [1 ]
Segars, William Paul [2 ]
Yin, Fang-Fang [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
关键词
4D-MRI; 4D-CT; tumor motion; respiratory motion; cine-MRI; COMPUTED-TOMOGRAPHY; MOTION; RADIOTHERAPY; XCAT; MOBILITY; PHANTOM;
D O I
10.1118/1.3658737
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Four-dimensional computed tomography (4D-CT) has been widely used in radiation therapy to assess patient-specific breathing motion for determining individual safety margins. However, it has two major drawbacks: low soft-tissue contrast and an excessive imaging dose to the patient. This research aimed to develop a clinically feasible four-dimensional magnetic resonance imaging (4D-MRI) technique to overcome these limitations. Methods: The proposed 4D-MRI technique was achieved by continuously acquiring axial images throughout the breathing cycle using fast 2D cine-MR imaging, and then retrospectively sorting the images by respiratory phase. The key component of the technique was the use of body area (BA) of the axial MR images as an internal respiratory surrogate to extract the breathing signal. The validation of the BA surrogate was performed using 4D-CT images of 12 cancer patients by comparing the respiratory phases determined using the BA method to those determined clinically using the Real-time position management (RPM) system. The feasibility of the 4D-MRI technique was tested on a dynamic motion phantom, the 4D extended Cardiac Torso (XCAT) digital phantom, and two healthy human subjects. Results: Respiratory phases determined from the BA matched closely to those determined from the RPM: mean (+/- SD) difference in phase: -3.9% (+/- 6.4%); mean (+/- SD) absolute difference in phase: 10.40% (+/- 3.3%); mean (+/- SD) correlation coefficient: 0.93 (+/- 0.04). In the motion phantom study, 4D-MRI clearly showed the sinusoidal motion of the phantom; image artifacts observed were minimal to none. Motion trajectories measured from 4D-MRI and 2D cine-MRI (used as a reference) matched excellently: the mean (6SD) absolute difference in motion amplitude: -0.3 (+/- 0.5) mm. In the 4D-XCAT phantom study, the simulated "4D-MRI" images showed good consistency with the original 4D-XCAT phantom images. The motion trajectory of the hypothesized "tumor" matched excellently between the two, with a mean (+/- SD) absolute difference in motion amplitude of 0.5 (+/- 0.4) mm. 4D-MRI was able to reveal the respiratory motion of internal organs in both human subjects; superior-inferior (SI) maximum motion of the left kidney of Subject #1 and the diaphragm of Subject #2 measured from 4D-MRI was 0.88 and 1.32 cm, respectively. Conclusions: Preliminary results of our study demonstrated the feasibility of a novel retrospective 4D-MRI technique that uses body area as a respiratory surrogate. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3658737]
引用
收藏
页码:6384 / 6394
页数:11
相关论文
共 32 条
  • [1] Investigation of sagittal image acquisition for 4D-MRI with body area as respiratory surrogate
    Liu, Yilin
    Yin, Fang-Fang
    Chang, Zheng
    Czito, Brian G.
    Palta, Manisha
    Bashir, Mustafa R.
    Qin, Yujiao
    Cai, Jing
    MEDICAL PHYSICS, 2014, 41 (10)
  • [2] Four-Dimensional Magnetic Resonance Imaging Using Axial Body Area as Respiratory Surrogate: Initial Patient Results
    Yang, Juan
    Cai, Jing
    Wang, Hongjun
    Chang, Zheng
    Czito, Brian G.
    Bashir, Mustafa R.
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (04): : 907 - 912
  • [3] Four-dimensional MRI using an internal respiratory surrogate derived by dimensionality reduction
    Uh, Jinsoo
    Khan, M. Ayaz
    Hua, Chiaho
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (21) : 7812 - 7832
  • [4] Four-dimensional diffusion-weighted MR imaging (4D-DWI): a feasibility study
    Liu, Yilin
    Zhong, Xiaodong
    Czito, Brian G.
    Palta, Manisha
    Bashir, Mustafa R.
    Dale, Brian M.
    Yin, Fang-Fang
    Cai, Jing
    MEDICAL PHYSICS, 2017, 44 (02) : 397 - 406
  • [5] Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients
    Zhang, Lei
    Yin, Fang-Fang
    Li, Tian
    Teng, Xinzhi
    Xiao, Haonan
    Harris, Wendy
    Ren, Lei
    Kong, Feng-Ming Spring
    Ge, Hong
    Mao, Ronghu
    Cai, Jing
    MEDICAL PHYSICS, 2021, 48 (12) : 7984 - 7997
  • [6] Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study
    Liu, Yilin
    Yin, Fang-Fang
    Chen, Nan-kuei
    Chu, Mei-Lan
    Cai, Jing
    MEDICAL PHYSICS, 2015, 42 (02) : 534 - 541
  • [7] Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID
    Yeo, Inhwan Jason
    Jung, Jae Won
    Yi, Byong Yong
    Kim, Jong Oh
    MEDICAL PHYSICS, 2013, 40 (05)
  • [8] Retrospective reconstruction of four-dimensional magnetic resonance from interleaved cine imaging - A comparative study with four-dimensional computed tomography in the lung
    Peteani, Giulia
    Paganelli, Chiara
    Giovannelli, Anna Chiara
    Bachtiary, Barbara
    Safai, Sairos
    Rogers, Susanne
    Pusterla, Orso
    Riesterer, Oliver
    Weber, Damien Charles
    Lomax, Antony John
    Baroni, Guido
    Fattori, Giovanni
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 29
  • [9] Respiratory motion–resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Kyungsoo Bae
    Kyung Nyeo Jeon
    Moon Jung Hwang
    Joon Sung Lee
    Sung Eun Park
    Ho Cheol Kim
    Anne Menini
    European Radiology, 2020, 30 : 5130 - 5138
  • [10] Respiratory motion-resolved four-dimensional zero echo time (4D ZTE) lung MRI using retrospective soft gating: feasibility and image quality compared with 3D ZTE
    Bae, Kyungsoo
    Jeon, Kyung Nyeo
    Hwang, Moon Jung
    Lee, Joon Sung
    Park, Sung Eun
    Kim, Ho Cheol
    Menini, Anne
    EUROPEAN RADIOLOGY, 2020, 30 (09) : 5130 - 5138